Eaton D2CB11 30 Replacement Circuit Breaker - Hazardous

Part Number: D2CB11 30
Eaton Crouse-Hinds logo
Manufacturer
Eaton Crouse-Hinds
Part number
D2CB11 30

Quick Summary

The Eaton Crouse-Hinds D2CB replacement circuit breaker assembly protects hazardous-area circuits with reliable single-pole protection. Maintenance in hazardous locations is challenging when parts must be compliant, sealed, and readily replaceable without triggering downtime. This unit aligns with NEC/CEC standards and NEC hazardous ratings Class I, Division 2, offering factory sealing for dust and moisture resistance. Choosing this assembly simplifies procurement, reduces spare-parts variety, and ensures seamless operation on 120/240 Vac systems. Engineers benefit from the compact dimensions and proven Eaton reliability, enabling safer, faster installations and lower total cost of ownership. This combination supports rapid, compliant deployments across plant floors.

Product Information

Extended Description

D2CB11 30 Eaton Crouse-Hinds: Eaton Crouse-Hinds series D2CB replacement circuit breaker assembly, 30A, Copper-free aluminum, Single-pole, Factory sealed, 120/240 Vac
Product Name
Eaton Crouse-Hinds series D2CB replacement circuit breaker assembly
Catalog Number
D2CB11 30
Product Length/Depth
4.44 in
Product Height
6.62 in
Product Width
1.23 in
Product Weight
1.6 lb
UPC
782274216775
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 2
Number Of Poles
Single-pole
Amperage Rating
30A
Voltage rating
120 Vac/240 Vac
Material
Copper-free aluminum
Special features
Factory sealed
Feature: Copper-free aluminum construction. The D2CB11 30 replacement circuit breaker uses copper-free aluminum, reducing weight and corrosion risk in harsh environments common to hazardous locations. This material choice yields tangible savings in on-site handling, shipping, and installation time, especially when replacing multiple units across a panel. Aluminum also delivers robust strength under vibration and temperature cycling typical of industrial facilities. With a compact footprint (4.44 in L x 6.62 in H x 1.23 in W), it fits neatly into standard Eaton Crouse-Hinds panel installations. Feature: Factory sealed design. This unit's factory seal protects critical contacts from dust, moisture, and corrosive atmospheres, which directly lowers field maintenance frequency. That reliability translates into reduced downtime and higher line efficiency in continuous-process environments. Supplied as a ready-to-install assembly, the D2CB11 30 eliminates the need for aftermarket sealing solutions. Support for easy procurement and consistent performance across multiple sites reduces operational risk. Feature: Electrical rating and compatibility. Rated 30A at 120/240 Vac, single-pole, the assembly protects specific branch circuits without altering upstream protection schemes. Its copper-free aluminum construction keeps weight manageable during replacement in crowded switchgear. The unit's dimensions and catalog number align with existing D2CB-based installations, supporting streamlined spares and faster MTTR. Designed for hazardous locations under NEC/CEC, the D2CB11 30 is ready for rapid deployment. Feature: Certifications and standards. Compliance with NEC/CEC and Class I, Division 2 ratings is essential for audits and customer acceptance. The Hazardous/Classified Locations area classification ensures correct installation location definitions. Factory sealing and documented performance reduce regulatory risk and accelerate commissioning. The combination of these certifications with a factory-sealed design offers a reliable path from procurement to operation. Feature: Installation and procurement advantages. Catalog number D2CB11 30 matches a proven family, enabling straightforward swap-in for legacy breakers. Dimensional consistency with 4.44 x 6.62 x 1.23 in allows reuse of existing mounting hardware. Overall, this replacement assembly supports faster maintenance cycles, lower inventory complexity, and better uptime in hazardous-area protection schemes. The unit's 30A rating and 120/240 Vac compatibility cover a wide range of automation applications, from machine control to process protection.

Get a Quick Quote for a Eaton Crouse-Hinds D2CB11 30

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds D2CB11 30? Enquire Now

FAQs

For Class I Division 2 hazardous locations, install the D2CB11 30 as a single-pole 30A breaker with 120/240 Vac rating inside a compliant enclosure. The unit's factory-sealed copper-free aluminum body minimizes ingress under dust and moisture conditions, while its compact footprint fits standard panels. Verify torque specs per installation sheets and maintain clearances per NEC/CEC guidelines.
Key specifications include a 30A amperage rating, 120/240 Vac voltage, single-pole configuration, and copper-free aluminum construction with a factory-sealed body. The unit is designed for hazardous locations with NEC/CEC compliance and Class I, Division 2 rating. Its compact dimensions (4.44 in L × 6.62 in H × 1.23 in W) simplify panel integration.
Yes, the D2CB11 30 is a replacement circuit breaker assembly in the D2CB family and is designed to fit compatible Eaton Crouse-Hinds panelboards and D2CB enclosures. Verify catalog numbers and enclosure spacing before replacement, but the 30A, single-pole, 120/240 Vac rating aligns with standard control-panel protection. Factory sealing supports use in harsh environments.
Certified for NEC/CEC standards with NEC hazardous rating Class I Division 2 and Hazardous/Classified Locations area classification, this D2CB11 30 meets regulatory requirements for safe operation in hazardous zones. The factory-sealed design further supports compliance by minimizing ingress risk during routine testing and maintenance. These certifications reduce risk during audits and streamline approvals for new installations.
Using the D2CB11 30 offers measurable ROI through reduced maintenance, fewer field replacements, and lower downtime in hazardous environments. The factory-sealed copper-free aluminum construction resists dust ingress and corrosion, extending service life and reducing spare-parts inventory. Its compatibility with existing D2CB panels minimizes retrofit costs, translating to faster maintenance cycles and longer system availability.