Quick Summary

Interlocked receptacle by Eaton Crouse-Hinds provides safe, lockable power isolation for hazardous-location equipment in heavy-industrial environments. Maintenance teams struggle with accidental energization during service, downtime, and safety risks in harsh settings. This unit meets NEC/CEC requirements and hazardous-location ratings, including Class II Division 1 and 2, Class III, and NEMA 3, 9, 12, ensuring reliable protection and regulatory compliance. By combining a 30A receptacle with a built-in 50A circuit-breaker and a spring-door enclosure, it supports quick, safe maintenance and reduces total cost of ownership. Designed for Arktite DBR applications, it offers long-term durability in demanding environments while aligning with your procurement goals for safety-first, compliant electrical protection.

Product Information

Extended Description

DBR53742 WT50 3 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Arktite DBR interlocked receptacle, 30A, 50A circuit breaker, Three-wire, four-pole, Brass contacts, With breaker, Style 2, Cutler-Hammer, Copper-free aluminum, Spring door, 1-1/2", 600 Vac
Product Name
Eaton Crouse-Hinds series Arktite DBR interlocked receptacle
Catalog Number
DBR53742 WT50 3
Product Length/Depth
7.25 in
Product Height
21.75 in
Product Width
8.13 in
Product Weight
30.7 lb
UPC
782274041698
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class II, Division 1 Class II, Division 2 Class III
NEMA Rating
3 9 12
Enclosure type
With breaker
Receptacle style
Spring door
Amperage Rating
30A
Grounding style
Style 2
Configuration
Three-wire, four-pole
Voltage rating
600 Vac
Trade size
1-1/2"
Circuit breaker amperage
50A
Manufacturer
Cutler-Hammer
Material
Copper-free aluminum
Contact material
Brass
Interlock mechanism prevents energization during maintenance, reducing the risk of arc flash and equipment damage. This translates to safer service procedures, faster turnaround times, and fewer costly downtime events in hazardous environments. The design aligns with lockout/tagout best practices and supports compliant procedures when personnel access enclosures in oil, gas, chemical, or mining facilities. The DBR53742 WT50 3 interlocked receptacle carries NEC/CEC compliance and hazardous-location ratings, including Class II Division 1 and 2 and Class III, complemented by NEMA 3, 9, 12 protection. Real-world deployment delivers measurable safety and productivity gains. Copper-free aluminum enclosure and spring-door receptacle provide durability in dusty, humid, or corrosive environments. The dust-ignitionproof construction minimizes ignition risk and simplifies inspection in hazardous zones. Industry data shows reduced maintenance cycles and longer interval warranties on rugged components. In practice, installers gain peace of mind knowing the unit withstands harsh ambient conditions without compromising electrical integrity. The combination of robust enclosure material and reliable contact metallurgy (brass) ensures consistent performance across temperature swings and vibration common in industrial facilities. Integrated protection with a 30A receptacle and a 50A circuit breaker streamlines panel design while maintaining safety margins. The 600 Vac rating supports heavy-duty motors and control circuits, and the three-wire four-pole configuration provides a solid ground reference. This setup reduces assembly time, minimizes miswiring, and simplifies fault isolation during testing. For OEMs and integrators, the product offers a drop-in replacement that preserves existing wiring schemes and reduces total cost of ownership through fewer spare parts, easier field servicing, and improved uptime in hazardous locations. Compliance-first and installation-ready, this unit ships with documented installation instructions (IF 1181) and datasheet access. Its NEC/CEC alignment, UL certification, and hazardous-locations ratings enable quick regulatory approvals and safer commissioning of equipment enclosures in safety-critical sectors.

Get a Quick Quote for a Eaton Crouse-Hinds DBR53742 WT50 3

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds DBR53742 WT50 3? Enquire Now

FAQs

The unit is designed for hazardous-location environments such as chemical plants, refineries, oil & gas facilities, and mining operations. Its interlocked design prevents energization during maintenance, supporting compliant lockout/tagout procedures and reducing ignition risk in Class II/Division 1 & 2 and Class III environments.
Key specs include a 30A receptacle, 50A circuit breaker, 600 Vac rating, three-wire, four-pole configuration, and a copper-free aluminum enclosure with brass contact material. It is shipped with an integrated breaker and a spring-door enclosure for quick, safe installation.
Yes. The DBR53742 WT50 3 supports hazardous-location ratings per Class II Division 1 & 2 and Class III, alongside NEC/CEC compliance and NEMA protections, making it appropriate for hazardous-area installations where ignition risk must be mitigated.
The unit adheres to NEC/CEC standards, is compatible with NEMA ratings 3, 9, 12, and is intended for hazardous/classified locations. It aligns with UL certification requirements and is designed to meet industry safety and performance benchmarks in harsh environments.
Download the IF 1181 installation sheet and the Eaton specification sheet for DBR53742 WT50 3 from Eaton’s site. Additional datasheet references and UL certification reports are available in the product downloads section for formal documentation and regulatory review.