Eaton Crouse-Hinds DL06 Legend Plate - Hazardous Locations
Part Number: DL06
Quick Summary
DL06 legend plate is a labeling accessory for Eaton Crouse-Hinds FlexStation control stations in hazardous locations. Label drift and mislabeling during maintenance can create safety risks and cause unplanned downtime, which this plate helps prevent. It aligns with NEC/CEC standards and hazardous-area ratings including Class I, Zone 1/Division 1 and Class II, as well as UL component certifications, reinforcing regulatory compliance. NEMA configurations 9, 3R, 7, and 12 support rugged environments found in chemical processing and oil/gas facilities. For procurement and operations, the DL06 integrates with 2-hole or 3-hole covers, delivering legible, durable labeling at scale. This accessory enhances field readability and maintenance efficiency in FlexStation explosionproof control stations, a value for engineering teams and reliability programs.
Product Information
Extended Description
DL06 Eaton Crouse-Hinds: Eaton Crouse-Hinds series FlexStation DL legend plate, Stop, Used with 2- or 3-hole covers
Product Name
Eaton Crouse-Hinds series FlexStation DL legend plate
Catalog Number
DL06
Product Length/Depth
2.25 in
Product Height
1.5 in
Product Width
0.01 in
Product Weight
0.005 lb
UPC
782274146850
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Zone 1 Class I, Division 1 Class I, Division 2 Class III Class I, Zone 2 Class II, Division 1 Class II, Division 2
NEMA Rating
9 3R 7 12
Legend plate inscription
Stop
Type
Used with 2- or 3-hole covers
FlexStation Explosionproof Control Station Components catalog page
FlexStation Explosionproof Control Station Components UL certification (Components)
FlexStation Explosionproof Control Station Components UL certification (Components)
FlexStation Explosionproof Control Station Components UL certification (Components)
IF 1928 - FlexStation Series Control Stations
IF 1928 - FlexStation Series Control Stations
IF 1928 - FlexStation Series Control Stations
Eaton Specification Sheet - DL06
Feature: Compact labeling solution for FlexStation DL legend plate; Business Impact: Optimizes panel real estate and keeps critical warnings legible in tight electrical enclosures; Application: Fits within the DL06 footprint on explosionproof control stations with 2-hole or 3-hole covers. Feature: Clear inscription and stop legend; Business Impact: Reduces operator confusion and prevents unintended stops during operation or servicing; Application: Essential in safety-critical circuits in hazardous locations. Feature: Broad certification coverage; Business Impact: Simplifies compliance audits and procurement processes by aligning with NEC/CEC, UL component certifications, and NEMA ratings; Application: Suitable for Class I/Zone 1 environments across chemical, oil, and gas facilities. Feature: Precise dimensions and weight; Business Impact: Lightweight, easy to handle during panel assembly and maintenance, minimizing install time; Application: Rapid field replacement without panel rework. Feature: 2-hole and 3-hole cover compatibility; Business Impact: Streamlines retrofits and upgrades by supporting existing enclosure configurations; Application: Common in FlexStation explosionproof control stations across plant floors. Industry insight: In harsh industrial settings, durable label reliability translates to measurable uptime gains and safer operation, making the DL06 a practical improvement for reliability engineers and procurement teams.
Get a Quick Quote for a Eaton Crouse-Hinds DL06
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds DL06?
Enquire Now
FAQs
To install the DL06, align the legend plate with the FlexStation enclosure and attach it to the 2-hole or 3-hole cover using the existing mounting pattern. Ensure the inscription is oriented for clear visibility and tighten fasteners to manufacturer torque values. This minimizes label wear and maintains legibility in harsh environments.
The DL06 is designed for use with 2-hole and 3-hole covers on FlexStation explosionproof control stations, allowing seamless integration into existing panel configurations without rework.
The DL06 supports NEC/CEC standards, Class I Zone 1 and Division ratings, and UL component certifications for hazardous locations, with NEMA ratings 9, 3R, 7, and 12 for rugged service.
The DL06 measures 2.25 inches in length, 1.5 inches in height, and 0.01 inches in width, weighing 0.005 lb. It bears UPC 782274146850 and labels with the inscription Stop, and is intended for use with 2- or 3-hole covers.
Deploying the DL06 improves labeling accuracy, reduces maintenance downtime, and supports regulatory compliance in hazardous locations, translating to safer operations and more efficient reliability programs for engineers and procurement teams.