Eaton Crouse-Hinds DSD SR30332 Selector Switch - Hazardous Locations

Part Number: DSD SR30332
Eaton Crouse-Hinds logo
Manufacturer
Eaton Crouse-Hinds
Part number
DSD SR30332

Quick Summary

Selector Switch DSD SR30332 is a rugged, explosion-protected control device for hazardous locations in industrial facilities. Operators often struggle with unreliable switches that fail in dust, moisture, or corrosive atmospheres. It meets NEC/CEC standards and hazardous-location ratings including Class I, Division 1; Class II, Division 1; Class III, with compatible NEMA enclosures rated 3, 5, 12. With 600 VAC operation and EDS/EFS back box compatibility, this selector switch enables compliant control in tough environments while reducing wiring complexity and maintenance costs. This combination of reliability, safety, and install efficiency supports streamlined control system design and safer plant operations.

Product Information

Extended Description

DSD SR30332 Eaton Crouse-Hinds: Eaton Crouse-Hinds series DSD-SR selector switch, 30A, Three-pole, 3, Double-throw with off, 600 Vac, EDS/EFS back boxes
Product Name
Eaton Crouse-Hinds series DSD-SR selector switch
Catalog Number
DSD SR30332
Product Length/Depth
2.38 in
Product Height
5.875 in
Product Width
3.5 in
Product Weight
1 lb
UPC
662276850057
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class II, Division 1 Class I, Division 1 Class III
NEMA Rating
3 5 12
Amperage Rating
30A
Voltage rating
600 Vac
Switch function
Double-throw with off
Number Of Poles
Three-pole
Number Of Positions
3
Used with
EDS/EFS back boxes
Feature → Business Impact → Application: The DSD SR30332 is a 30A, 600 VAC selector switch with three poles and three positions, double-throw with off. This capability delivers robust control for demanding motors and feeders in hazardous locations, reducing the risk of overload and misoperation while enabling precise process control in chemical plants and mining sites. Feature → Business Impact → Application: It is compatible with EDS/EFS back boxes, which speeds installation, simplifies wiring, and minimizes field modification. This translates to shorter commissioning times and lower labor costs on new builds or retrofit projects in oil & gas facilities and heavy industry. Feature → Business Impact → Application: Certified for NEC/CEC and hazardous area classifications (Class II, Division 1; Class I, Division 1; Class III) with NEMA ratings 3, 5, 12, ensuring compliance across global markets. This supports cross-border projects and reduces regulatory risk. Feature → Business Impact → Application: Durable enclosure characteristics and a modest weight (1 lb) contribute to easier handling, reliable operation in vibration-prone environments, and lower shipping costs. This is especially valuable for remote installations in petrochemical plants and mining operations. Feature → Business Impact → Application: The unit’s 3-position, 3-pole design with a robust throw profile provides safe stop/start sequencing, helping maintenance teams implement safer lockout-tagout procedures and extend switch life under harsh operating conditions.

Get a Quick Quote for a Eaton Crouse-Hinds DSD SR30332

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds DSD SR30332? Enquire Now

FAQs

Yes. The DSD SR30332 is specified for use with EDS/EFS back boxes, which streamlines mounting and wiring in hazardous environments. This compatibility reduces installation time, minimizes field modifications, and helps ensure a secure, compliant enclosure assembly in classification areas such as Class I and II locations.
The switch is rated for 30A at 600 VAC, with three poles and three positions. It features a double-throw with off function, suitable for safe sequencing and emergency stop applications. This combination supports reliable control of motors and feeders in demanding industrial settings while meeting hazardous-location requirements.
Yes. The DSD SR30332 carries NEC/CEC compliance and hazardous-location ratings that include Class I, Division 1; Class II, Division 1; and Class III. It also conforms to related standards and enclosure ratings (NEMA 3, 5, 12), making it appropriate for chemical, oil & gas, and mining environments.
The device supports hazardous-location classifications with NEC/CEC standards and NEMA ratings of 3, 5, and 12. This combination ensures protection against dust, water ingress, and harsh conditions, aligning with industry requirements for safe operation in hazardous process areas and demanding outdoor or plant-floor environments.
By delivering reliable operation in harsh environments and enabling faster installation with EDS/EFS back boxes, the DSD SR30332 reduces downtime and maintenance costs. Its durable construction, clear sequencing, and regulatory compliance minimize field repairs and rework, contributing to lower total cost of ownership in automation projects.