Eaton's DSDX947 J1 J3 SA is a pilot light cover for hazardous-area control stations. The challenge is delivering reliable illumination and enclosure protection in harsh environments where corrosion, washdowns, or ingress can obscure indicators and cause downtime. It achieves IP66 and NEMA 4X protection and supports NEC/CEC compliance, with Class I Division 2 and Zone 2 approvals for hazardous locations. For engineers and procurement teams, the copper-free aluminum construction, gasketed sealing, and two integrated pilot lights reduce maintenance, simplify wiring, and lower lifecycle costs while ensuring clear status signals in demanding plants and offshore facilities.
Product Information
Extended Description
DSDX947 J1 J3 SA Eaton Crouse-Hinds: Eaton Crouse-Hinds series DSDX pilot light cover and device sub-assembly, Red/green, Copper-free aluminum, Gasketed, Two pilot lights
Product Name
Eaton's Crouse-Hinds series DSDX pilot light cover and device sub-assembly
Catalog Number
DSDX947 J1 J3 SA
Product Length/Depth
7.03 in
Product Height
3.88 in
Product Width
3.5 in
Product Weight
2 lb
UPC
662283346147
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 2 Class I, Zone 2 Class II, Division 1 Class III
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Color
Red/green
Material
Copper-free aluminum
Special features
Gasketed
Type
Two pilot lights
EDS/EDSX and DSD/DSDX hazardous area control stations and switches - brochure
DSD and DSDX Cover and Device Sub-assemblies catalog page
DSD Explosionproof Cover and Device Sub-assemblies UL certification
DSD Explosionproof Cover and Device Sub-assemblies UL certification
IF 1424 - DSD, GFS, CPS and ENR Series Replacement Covers
IF 1424 - DSD, GFS, CPS and ENR Series Replacement Covers
IF 1424 - DSD, GFS, CPS and ENR Series Replacement Covers
Eaton Specification Sheet - DSDX947 J1 J3 SA
EDSX and DSDX Technical Data Sheet
Copper-free aluminum housing provides corrosion resistance while keeping weight manageable, translating to longer service life in marine and chemical environments and reducing replacement costs. This feature supports safer handling during installation and lowers total cost of ownership by minimizing repainting and maintenance cycles. The gasketed design delivers IP66 protection and enhanced ingress resistance, enabling reliable operation in washdowns, dust, and moisture-prone areas common in hazardous locations, which in turn minimizes unscheduled downtime and extends equipment life for critical lines. The two pilot lights give distinct Red/Green indications for status clarity, improving operator response times and reducing misinterpretation during high-pressure shifts. NEMA 4X compatibility and rugged construction support both indoor and outdoor installations, streamlining procurement and stock-keeping for mixed-use facilities. Compliance with NEC/CEC and hazardous-location ratings simplifies engineering reviews and accelerates approvals, helping projects stay on schedule. The compact two-pilot-light sub-assembly integrates easily with DSD/DSDX control stations, reducing field wiring and enabling faster commissioning in plant upgrades and new builds. Industry users benefit from a proven enclosure solution that delivers predictable performance, lower maintenance, and improved safety in chemical plants, refineries, and offshore facilities.
Get a Quick Quote for a Eaton Crouse-Hinds DSDX947 J1 J3 SA
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds DSDX947 J1 J3 SA?
Enquire Now
FAQs
Install as a dedicated pilot light cover and device sub-assembly for DSD/DSDX control stations. Ensure gasket seating is uniform and that the enclosure is mounted to meet IP66 and NEMA 4X requirements. Use the two integrated pilot lights for clear status indication, and follow NEC/CEC guidelines for Class I Division 2, Zone 2 locations to maintain compliance.
The DSDX947 J1 J3 SA provides hazardous-location approvals including Class I, Division 2 and Zone 2, with IP66 ingress protection and a NEMA 4X enclosure rating. It adheres to NEC/CEC standards and supports UL listings referenced in Eaton’s certification literature for explosion-protected devices in hazardous environments.
Yes. The DSDX947 J1 J3 SA is a cover and device sub-assembly designed for use with DSD/DSDX hazardous-area control stations and switches, offering gasketed sealing, two pilot lights, and copper-free aluminum housing to simplify integration and maintenance while ensuring regulatory compliance.
Product length/depth is 7.03 inches, height is 3.88 inches, and width is 3.5 inches. The unit weighs 2 pounds, and uses copper-free aluminum with gasketed construction for robust protection in demanding environments.
Copper-free aluminum reduces corrosion-related maintenance, and the gasketed IP66/NEMA 4X enclosure minimizes ingress-related downtime. The two pilot lights provide clear status signals, reducing misreads and fault investigations, while straightforward installation shortens commissioning time, delivering lower lifecycle costs and improved uptime for hazardous-area facilities.