The Eaton Crouse-Hinds Roughneck E1049X-2 plug provides high-current power connections for hazardous-location equipment. This rugged interface addresses the challenge of delivering reliable, safe connections in Zone 2 environments where vibration, moisture, or limited space threaten uptime. With Zone 2 IECEx/ATEX certification and NEC/CEC compliance, plus IP54 protection and a NEMA 3R enclosure rating, this plug supports both safety and durability in harsh plants. The solution pairs a rubber body with copper contacts and a choice of hexagon crimp or solder connections, enabling fast, secure installations. Built for industrial automation and heavy electrical feeders, it helps you meet regulatory requirements while reducing maintenance costs and drivetrain downtime.

Product Information

Extended Description

E1049X-2 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Roughneck E1049 plug, Up to 898A continuous, 535 kcmil, Yellow, Hexagon crimp or solder, Copper contacts, Male, Rubber, Zone 2 rated, 1000 Vac/dc
Product Name
Eaton Crouse-Hinds series Roughneck E1049 plug
Catalog Number
E1049X-2
Product Length/Depth
8.5 in
Product Height
2.16 in
Product Width
2.16 in
Product Weight
1 lb
UPC
662275961716
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC IECEx/ATEX
NEC hazardous rating
Class I, Division 2
IECEx/ATEX hazardous rating
Zone 2
NEMA Rating
3R
Ingress protection (IP) ratings
IP54
Cable size
535 kcmil
Amperage Rating
Up to 898A Continuous
Voltage rating
1000 Vac/dc
Gender
Male
Connection type
Hexagon crimp or solder
Color
Yellow
Material
Rubber
Contact material
Copper
Special features
Zone 2 rated
High current rating up to 898A continuous and a 535 kcmil cable capacity are matched by copper contacts and a rugged rubber body, enabling you to consolidate large motor connections into a single, robust plug. Business impact: fewer components, lower installation time, and reduced voltage drop on long runs in demanding environments. Application: heavy-duty motor feeders and high-amperage power-inlet points in mining, steel, or chemical processing facilities. The Zone 2 rated design, supported by NEC/CEC and IECEx/ATEX certifications, delivers compliant performance in hazardous locations, reducing compliance risk and enabling safer maintenance windows. Application: chemical plants, oil and gas sites, and other classified-area installations where regulatory alignment is non-negotiable. IP54 protection and a NEMA 3R enclosure rating defend against dust and splashes, improving uptime and minimizing service calls in dusty or wet environments. The yellow rubber enclosure and copper contacts support visibility and electrical integrity, while hexagon crimp or solder connection options provide flexible installation methods. This Roughneck plug is designed to integrate with existing Roughneck systems, enabling quick upgrades without reworking cables. Benefits include faster commissioning, consistent performance across temperature and vibration, and reduced total cost of ownership for large-scale electrical feeders.

Get a Quick Quote for a Eaton Crouse-Hinds E1049X-2

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds E1049X-2? Enquire Now

FAQs

Yes. The E1049X-2 is designed for copper contacts with both hexagon crimp and solder connection options, supporting 535 kcmil cables. It integrates with the Roughneck family and requires standard crimp tooling for clean, repeatable terminations. Refer to IF 1777/IF 1778 installation sheets for detailed procedures and torque/ crimptool recommendations.
The E1049X-2 is rated for up to 898A continuous and 1000 Vac/dc, making it suitable for high-power motor feeders and large electrical loads in Zone 2 hazardous environments. Ensure cable size is 535 kcmil and verify routing and enclosure integrity per NEC/CEC and IECEx/ATEX guidelines.
Ideal for heavy industrial settings such as mining, metals processing, chemical plants, and oil and gas facilities where Zone 2 classifications apply. Its Zone 2 rating, IP54 protection, and NEMA 3R enclosure support reliable operation in harsh environments, while the 535 kcmil copper conductors accommodate high-current motor and feeder applications.
The E1049X-2 carries NEC/CEC and IECEx/ATEX standards with Zone 2 hazardous location certification, Class I, Division 2, IP54 ingress protection, and NEMA 3R enclosure rating. This combination ensures regulatory compliance for hazardous-area installations and reduces risk during commissioning and maintenance.
Access the Roughneck literature and installation sheets (IF 1777/IF 1778), brochures, and catalog pages listed in the product downloads. These resources aid fast installation, validation of certifications, and ongoing maintenance planning, delivering lower downtime and better lifecycle cost for high-amperage, hazardous-location connectors.