Eaton EAJB16 WOD Condulet Outlet Box - Hazardous Locations
Part Number: EAJB16 WOD
Manufacturer
Eaton Crouse-Hinds
Part number
EAJB16 WOD
Quick Summary
Eaton EAJB16 WOD Condulet Outlet Box provides rugged conduit terminations for hazardous-area installations. Facility managers and engineers often struggle with corrosion, maintenance downtime, and code-compliance delays in harsh environments. This enclosure carries NEC/CEC compliance, NEMA ratings 3, 4, 7, and 9, and hazardous-location classifications Class I/II, Division 1/2 to minimize risk. With a feraloy iron alloy body and cover and a 1/2 inch trade size, it delivers reliable protection, easier installation, and lower total cost of ownership for industrial electrical assemblies. For projects requiring safe, compliant, and durable enclosures, EAJB16 WOD aligns with both engineering standards and procurement goals.
Product Information
Extended Description
EAJB16 WOD Eaton Crouse-Hinds: Eaton Crouse-Hinds series Condulet EAJ conduit outlet box with cover, 3-3/16" cover opening diameter, Feraloy iron alloy body and cover, B shape, 1/2"
Product Name
Eaton Crouse-Hinds series Condulet EAJ conduit outlet box with cover
Catalog Number
EAJB16 WOD
Product Length/Depth
4.53 in
Product Height
4.53 in
Product Width
4.03 in
Product Weight
4.68 lb
UPC
782274981147
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2 Class II, Division 1 Class II, Division 2 Class III
NEMA Rating
3 4 7 9
Shape
B
Trade size
1/2"
Cover opening diameter
3-3/16"
Material
Feraloy iron alloy
Special features
Feraloy iron alloy cover
Crouse-Hinds series EAJ Conduit Outlet Boxes catalog page
IF 1730 - GUA/EAB/EAJ Condulet Outlet Boxes
Eaton Specification Sheet - EAJB16 WOD
Industrial Fittings Bend Radius and Cubic Capacity Chart
Feature: Feraloy iron alloy body and cover provide superior durability and corrosion resistance in aggressive environments. Business Impact: Longer service life and reduced maintenance costs in offshore, chemical, and mining applications. Application: Ideal for Condulet outlet boxes in demanding facilities where durability matters. Feature → Business Impact → Application: Compact 4.53 in dimensions and 1/2 inch trade size enable easy integration into tight control panels while maintaining robust protection; reduces enclosure footprint without sacrificing protection in precision industrial installations. Feature → Business Impact → Application: NEMA ratings 3, 4, 7, 9 and hazardous-location classification support safe outdoor, chemical, and explosive atmospheres; simplifies compliance across multiple sites and projects. Feature → Business Impact → Application: B-shaped enclosure with a 3-3/16 inch cover opening ensures secure access and reliable sealing; supports straightforward installation and maintenance in field conditions. Feature → Business Impact → Application: Comprehensive documentation including IF 1730 installation sheets and catalogs enhances procurement accuracy and reduces project risk, enabling faster approval and deployment.
Get a Quick Quote for a Eaton Crouse-Hinds EAJB16 WOD
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds EAJB16 WOD?
Enquire Now
FAQs
EAJB16 WOD installations should follow the IF 1730 instruction sheets and local code requirements ( NEC/CEC ). Mount the box to a compliant panel or surface, route 1/2" conduit as specified, and verify the 3-3/16" cover opening and feraloy iron alloy cover seal for a secure enclosure. Ensure proper grounding and sealing to protect Class I/II, Division 1/2 circuits in hazardous locations.
The EAJB16 WOD provides a hazardous-location enclosure with Class I/Division 1 ratings, aided by a feraloy iron alloy body and cover and a 1/2" trade size. Its NEMA ratings 3, 4, 7, 9 and NEC/CEC compliance ensure that terminations remain protected against dust, water, chemicals, and explosive atmospheres, reducing risk in critical control systems.
Yes. The EAJB16 WOD carries NEMA ratings 3, 4, 7, and 9, which cover outdoor exposure, water ingress, and harsh environments. Its feraloy iron alloy construction adds corrosion resistance, making it a suitable choice for outdoor enclosures and hazardous-area installations where moisture and contaminants are present.
The EAJB16 WOD adheres to NEC/CEC standards and hazardous-area classifications, aligning with Class I/II, Divisions 1/2 requirements. Its robust ferralo y alloy construction and certified cover design provide reliable protection for conduit terminations, helping maintain compliance during inspections and audits in industrial facilities.
Official documentation includes the Crouse-Hinds Conduit Outlet Boxes catalog page, IF 1730 installation sheets, and Eaton specification sheets for the EAJB16 WOD. These resources facilitate correct installation, specify compatible conduit, and support procurement and QA reviews in project packages.