Eaton EAJB36 Condulet Outlet Box - Hazardous Location

Part Number: EAJB36
Manufacturer
Eaton Crouse-Hinds
Part number
EAJB36

Quick Summary

The Eaton Crouse-Hinds EAJB36 Condulet outlet box protects conduit terminations in demanding industrial environments. Designed for hazardous and classified locations, it simplifies field wiring while meeting strict code requirements. Choosing rugged, code-compliant enclosures can slow projects and raise compliance risk, but this unit delivers reliable protection with minimal downtime. It carries NEC/CEC compliance and supports hazardous location ratings, including Class I, Division 1 and 2, as well as Class II and III, plus sturdy NEMA ratings 3, 4, 7, and 9. With a 1" trade size, a 3-3/16" cover opening, and Feraloy iron alloy construction, it offers durability and easy installation for industrial control panels, refineries, or chemical plants. The combination of robust materials and documented certifications translates to lower total cost of ownership and faster approvals for your projects.

Product Information

Extended Description

EAJB36 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Condulet EAJ conduit outlet box with cover, 3-3/16" cover opening diameter, Feraloy iron alloy, B shape, 1"
Product Name
Eaton Crouse-Hinds series Condulet EAJ conduit outlet box with cover
Catalog Number
EAJB36
Product Length/Depth
4.66 in
Product Height
4.66 in
Product Width
4.53 in
Product Weight
16.2 lb
UPC
782274943763
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2 Class II, Division 1 Class II, Division 2 Class III
NEMA Rating
3 4 7 9
Shape
B
Trade size
1"
Cover opening diameter
3-3/16"
Material
Feraloy iron alloy
Feature: Feraloy iron alloy construction provides exceptional strength and corrosion resistance. Business Impact: Extends service life in harsh environments, reducing maintenance cycles and replacement costs. Application: chemical plants, oil & gas facilities, and outdoor installations where rugged protection is critical. Feature: Shape B enclosure with a 1" trade size enables standard conduit terminations. Business Impact: simplifies wiring schematics and stocking for maintenance teams, lowering installation time and errors. Application: control cabinets and terminal housings in industrial facilities. Feature: Cover opening diameter of 3-3/16" supports straightforward device mounting and accessibility. Business Impact: faster device replacement and easier field modifications, improving responsiveness to process changes. Application: panel upgrades and routine wiring changes in hazardous locations. Feature: NEC/CEC compliance with NEMA ratings 3, 4, 7, 9 delivers regulatory alignment and reliable protection. Business Impact: reduces approval cycles, minimizes non-conformance risk, and supports safer commissioning. Application: electrical installations across refineries, chemical plants, and manufacturing sites. Feature: Hazardous location ratings Class I, Division 1 & 2; Class II & III ensure suitability for a broad range of environments. Business Impact: expands project scope without changing enclosures, enabling standardized procurement. Application: industries with flammable or combustible atmospheres requiring certified enclosures. Feature: Compatibility with Condulet system provides installation flexibility and future upgrade paths. Business Impact: lowers lifecycle costs by enabling quick reconfiguration or expansion. Application: evolving control systems and scalable electrical infrastructure.

Get a Quick Quote for a Eaton Crouse-Hinds EAJB36

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds EAJB36? Enquire Now

FAQs

The EAJB36 is a B-shaped 1" trade size conduit outlet box designed to mate with Eaton Condulet components in hazardous environments. Its Class I Division 1/2 and Class II/III ratings align with NEC/CEC requirements, enabling seamless integration with EAJ/EAB series installations and straightforward wiring terminations in approved enclosures.
Installers should verify enclosure mounting per NEC/CEC guidelines, ensure proper sealing for hazardous atmospheres, and use compatible gaskets and fittings. Refer to IF 1730 for installation sheets. With a 3-3/16" cover opening and 1" trade size, plan for device clearance and wiring space to maintain compliance and ease maintenance.
EAJB36 carries NEC/CEC compliance and multiple NEMA ratings (3, 4, 7, 9), along with hazardous location classifications (Class I, Division 1 & 2; Class II & III). These certifications validate suitability for harsh environments, streamline approvals, and reduce risk when wiring and sealing electrical terminations in hazardous areas.
Yes. The EAJB36 is designed to integrate with Eaton Crouse-Hinds Condulet systems, supporting standardized terminations and ease of expansion. Benefits include consistent installation practices across sites, faster panel upgrades, and reduced inventory complexity when scaling electrical infrastructure in industrial facilities.
The enclosure’s rugged Feraloy iron alloy construction reduces corrosion-related maintenance and extends service life, lowering total cost of ownership. Certified ratings help avoid rework and delays during audits, delivering faster project completion and predictable maintenance cycles for long-term reliability.