Quick Summary
EAJC16 DIN16 is a Condulet conduit outlet box designed for rugged hazardous-location installations. Engineers often struggle with mounting in compact panels and ensuring reliable conductor terminations in demanding environments. This enclosure earns NEC/CEC compliance and carries Class I, Division 1 and Division 2, Class II, Division 1 and 2, and Class III ratings, along with NEMA ratings 3, 4, 7, and 9, providing robust protection across tough sites. With DIN rail compatibility, six terminal blocks, and a 1/2 inch trade size, it accelerates installation and reduces panel footprint. For OEMs and end users, it translates to faster commissioning, safer installations, and lower total cost of ownership through longer life and easier maintenance.
Product Information
Extended Description
EAJC16 DIN16 Eaton Crouse-Hinds: Eaton Crouse-Hinds series Condulet EAJ conduit outlet box with cover, 3-3/16" cover opening diameter, Feraloy iron alloy, C shape, DIN rail mounted, 6 terminal blocks, 1/2"
Product Name
Eaton Crouse-Hinds series Condulet EAJ conduit outlet box with cover
Catalog Number
EAJC16 DIN16
Product Length/Depth
5.31 in
Product Height
3.75 in
Product Width
2.53 in
Product Weight
4.1 lb
UPC
662276689091
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2 Class II, Division 1 Class II, Division 2 Class III
NEMA Rating
3 4 7 9
Shape
C
Trade size
1/2"
Cover opening diameter
3-3/16"
Material
Feraloy iron alloy
Special features
DIN rail mounted, 6 terminal blocks
Crouse-Hinds series EAJ Conduit Outlet Boxes catalog page
IF 1730 - GUA/EAB/EAJ Condulet Outlet Boxes
Eaton Specification Sheet - EAJC16 DIN16
Industrial Fittings Bend Radius and Cubic Capacity Chart
Feature: DIN rail mounted construction enables fast integration with standard control cabinets, reducing installation time and panel footprint. Benefit: Shorter project timelines and lower field labor costs in automation environments. Application: Automation cabinets in manufacturing and process facilities. Feature: Feraloy iron alloy housing delivers rugged, corrosion-resistant protection in harsh environments. Benefit: Longer service life and fewer enclosure replacements, lowering maintenance spend and downtime. Application: Oil, gas, chemical processing, and other demanding locations. Feature: C-shaped body with 1/2 in trade size and 3-3/16 in cover opening diameter simplifies compatibility with common conduit fittings and terminal blocks. Benefit: Easier wiring and reliable seals, reducing rework and leakage risk. Application: Control panels and instrumentation enclosures in hazardous areas. Feature: Six terminal blocks within a compact footprint support multi-circuit terminations without additional boxes. Benefit: Higher wiring density, simplified traceability, and reduced panel complexity. Application: Complex control circuits and distributed I/O in process automation. Feature: NEC/CEC compliance, Class I/II/III hazardous-location ratings, and NEMA 3, 4, 7, 9 protection. Benefit: Regulatory peace of mind, safer operation, and quicker validation during audits. Application: Hazardous-location installations across mining, chemical, and energy sectors. Feature: DIN rail compatibility and documented installation guidance (IF 1730). Benefit: Streamlined field installation and consistent performance across installations. Application: OEM panel builds and field retrofits. Feature: Dimensions and weight (5.31 in L, 3.75 in H, 2.53 in W, 4.1 lb). Benefit: Predictable fit within compact cabinets and manageable weight for installation and mounting. Application: Space-constrained electrical infrastructure in industrial plants.
Get a Quick Quote for a Eaton Crouse-Hinds EAJC16 DIN16
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds EAJC16 DIN16?
Enquire Now
FAQs
Mount the enclosure onto standard DIN rails inside the control panel, connect conductors to the six terminal blocks, and secure the lid to maintain a tight seal. The DIN rail interface is designed for quick snap-in installation and reliable retention in rugged environments.
Yes. The EAJC16 DIN16 is rated for NEC/CEC hazardous locations with Class I Division 1 and Division 2, as well as Class II Division 1 and 2 and Class III, providing robust protection in demanding environments.
Dimensions are 5.31 in length, 3.75 in height, and 2.53 in width, with a weight of 4.1 lb. It supports 6 terminal blocks and a 1/2 in trade size, with a 3-3/16 in cover opening diameter.
It carries NEC/CEC compliance, NEMA ratings 3, 4, 7, 9, and hazardous-location classifications including Class I, II, and III across divisions, ensuring regulatory compliance for hazardous environments.
Its rugged Feraloy iron alloy housing extends service life, reducing replacement costs, while DIN rail mounting and six-terminal wiring streamline installation and maintenance, lowering downtime and total cost of ownership.