Eaton Crouse-Hinds EAJL16 WOD Condulet - Hazardous Locations
Part Number: EAJL16 WOD
Manufacturer
Eaton Crouse-Hinds
Part number
EAJL16 WOD
Quick Summary
EAJL16 WOD Condulet outlet box secures electrical connections for hazardous-location enclosures in industrial facilities. In harsh environments, keeping terminations protected from dust, moisture, and gas is critical to avoiding downtime and safety incidents. Certified for Hazardous/Classified Locations under NEC/CEC, with NEMA ratings 3, 4, 7 and 9 to withstand demanding service. Designed for fast installs and long-term reliability, it reduces field rework and maintenance calls. As a Condulet conduit outlet box, it supports rugged industrial enclosures, delivering dependable performance in automation and process industries. This combination of robust materials, codified compliance, and thoughtful footprint translates to lower total cost of ownership and safer, more compliant installations.
Product Information
Extended Description
EAJL16 WOD Eaton Crouse-Hinds: Eaton Crouse-Hinds series Condulet EAJ conduit outlet box with cover, 3-3/16" cover opening diameter, Feraloy iron alloy body and cover, L shape, 1/2"
Product Name
Eaton Crouse-Hinds series Condulet EAJ conduit outlet box with cover
Catalog Number
EAJL16 WOD
Product Length/Depth
4.53 in
Product Height
4.53 in
Product Width
2.53 in
Product Weight
4.58 lb
UPC
782274974910
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2 Class II, Division 1 Class II, Division 2 Class III
NEMA Rating
3 4 7 9
Shape
L
Trade size
1/2"
Cover opening diameter
3-3/16"
Material
Feraloy iron alloy
Special features
Feraloy iron alloy cover
Crouse-Hinds series EAJ Conduit Outlet Boxes catalog page
IF 1730 - GUA/EAB/EAJ Condulet Outlet Boxes
Eaton Specification Sheet - EAJL16 WOD
Industrial Fittings Bend Radius and Cubic Capacity Chart
Feature: Feraloy iron alloy body and cover provide rugged durability under vibration, impact, and chemical exposure. Business Impact: Extended enclosure life reduces replacement costs and downtime. Application: Ideal for heavy-duty facilities with washdowns or corrosive atmospheres, including mining, chemical processing, and oil & gas. Feature: L-shaped body with 1/2" trade size and a 3-3/16" cover opening ensures compatibility with standard conduits and tight installation spaces. Business Impact: Simplifies wiring routes and speeds commissioning in compact plant layouts. Application: Perfect for wall- or surface-mounted installations in confined electrical rooms and equipment pads. Feature: Hazardous/Classified Locations certification with NEC/CEC compliance and NEMA ratings 3, 4, 7, 9. Business Impact: Delivers code-conforming protection for safety-critical systems, reducing regulatory risk. Application: Suitable for oil & gas, chemical processing, and heavy industrial automation where enclosure integrity matters. Feature: Compact footprint with precise dimensions (4.53 in length/depth, 4.53 in height, 2.53 in width) and 4.58 lb weight. Business Impact: Predictable fit simplifies retrofits and spare-part planning, lowering installation time. Application: Fits standard panel openings and conduit feeds in retrofit or new-build projects. Feature: Documentation and installation guidance (IF 1730 and datasheet) improve field productivity. Business Impact: Reduces miswiring and rework by providing clear guidance. Application: Streamlines procurement-to-installation workflows for electrical teams in hazardous environments.
Get a Quick Quote for a Eaton Crouse-Hinds EAJL16 WOD
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds EAJL16 WOD?
Enquire Now
FAQs
For hazardous environments, install the EAJL16 WOD as a wall- or surface-mounted conduit outlet box with the 1/2" trade size fittings. Follow the IF 1730 instruction sheet for conduit entries, sealing, and ground continuity to ensure protection against dust, moisture, and corrosive exposure while maintaining NEC/CEC compliance.
Yes. The box is designed around a 1/2" trade size, with an L-shaped footprint that accommodates common conduit fittings. Refer to the installation instructions (IF 1730) for recommended fittings and mounting guidance to guarantee reliable terminations in tight or restricted spaces.
The EAJL16 WOD is certified for Hazardous/Classified Locations under NEC/CEC, and it carries NEMA ratings 3, 4, 7, and 9. These ratings, along with the Feraloy iron alloy construction, support safe operation in Class I, Division 1 and 2 environments, Class II, Division 1 and 2, and Class III conditions.
The enclosure measures 4.53 inches in length/depth and height, 2.53 inches in width, with a product weight of 4.58 pounds. The cover opening diameter is 3-3/16 inches, and the trade size is 1/2 inch, supporting standard wiring and fit in restricted spaces.
The Condulet EAJL16 WOD provides rugged protection for terminations, code-compliant installation in hazardous locations, and predictable fit for retrofits. This reduces downtime, simplifies procurement, and lowers total cost of ownership by improving reliability, safety, and maintenance efficiency in harsh industrial environments.