Eaton EBM Disconnect S753 S756V W30360 - Hazardous Locations

Part Number: EBMBB FD S753 S756V W30361 S784
Eaton Crouse-Hinds logo
Manufacturer
Eaton Crouse-Hinds
Part number
EBMBB FD S753 S756V W30361 S784

Quick Summary

Eaton Crouse-Hinds EBM disconnect switch provides rugged isolation for hazardous-location electrical systems in industrial facilities. Design teams often grapple with safety gaps, unplanned downtime, and compliance risk in explosion-prone environments. This model delivers NEC/CEC compliance along with hazardous-location ratings (Class I, Division 1 and Division 2; Class II, Division 1 and 2; Class III) and diverse NEMA protections to keep systems running. The copper-free aluminum enclosure, epoxy powder coat finish, and built-in breather/drain minimize corrosion and moisture ingress in harsh plants. Easy to install and compatible with standard switchgear footprints, it reduces installation time and lifecycle costs while meeting stringent code requirements.

Product Information

Extended Description

EBMBB FD S753 S756V W30361 S784 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EBM disconnect switch, 30A, With switch, Fused, 5 HP/7.5 HP, Copper-free alum, Polyphase, Internal and external epoxy powder coat finish, std breather and drain, 1A and 1B contacts aux switch, 200-600 Vac/250 Vdc
Product Name
Eaton Crouse-Hinds series EBM disconnect switch
Catalog Number
EBMBB FD S753 S756V W30361 S784
Product Length/Depth
14.46 in
Product Height
26.9 in
Product Width
10.25 in
Product Weight
101 lb
UPC
662276695184
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class II, Division 1 Class I, Division 1 Class II, Division 2 Class I, Division 2 Class III
NEMA Rating
7 4 3 3R 9 12 4X
Enclosure type
With switch
Fusing
Fused
Amperage Rating
30A
Phase
Polyphase
Voltage rating
200-600 Vac / 250 Vdc
Horsepower
5 hp/7.50 hp
Material
Copper-free aluminum
Special features
Internal and external epoxy powder coat finish, standard breather and drain, 1A and 1B contacts auxiliary switch
Feature: Explosionproof construction with a copper-free aluminum enclosure. Benefit: Delivers durable protection in harsh environments, reducing corrosion, maintenance needs, and overall lifecycle costs. Application: Suitable for chemical plants, oil & gas facilities, and mining operations where ignition risk must be controlled. Feature: Internal and external epoxy powder coat finish with standard breather and drain. Benefit: Guards against moisture ingress and washdown damage, extending service intervals. Application: Ideal for Ohio River valley, coastal facilities, and outdoor installations where exposure to humidity is common. Feature: 30A non-fused, polyphase design supporting 7.5–25 HP across 200-600 Vac / 250 Vdc. Benefit: Flexible motor control for pumps, fans, and conveyors with a single robust device. Application: Retrofit projects and new builds in process industries. Feature: Broad enclosure ratings including NEMA 4, 7, 3R, 4X, 12, 3, 9. Benefit: Supports versatile installations and regulatory compliance across multiple geographic regions. Application: Hazardous-location plants with varied ambient conditions. Feature: Standard breather and drain plus installation-friendly footprint. Benefit: Simplifies field wiring and maintenance planning, reducing downtime. Application: End-users seeking predictable uptime in demanding environments.

Get a Quick Quote for a Eaton Crouse-Hinds EBMBB FD S753 S756V W30361 S784

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds EBMBB FD S753 S756V W30361 S784? Enquire Now

FAQs

This unit is designed for standard switchgear footprints and enclosure interfaces used in industrial facilities. With a length of 14.46 in, height of 26.9 in, and width of 10.25 in, it integrates readily into existing control cabinets and process lines, minimizing field modifications and allowing quick commissioning in hazardous environments.
The switch is rated for 30A with a non-fused configuration, supporting 200-600 Vac and 250 Vdc. It controls 7.5 HP, 10 HP, 20 HP, and 25 HP motors across a polyphase setup, making it suitable for a range of drives and load profiles while maintaining safe isolation in hazardous locations.
Yes. It features hazardous/classified location area classification and NEC/CEC compliance, with NEC ratings covering Class I Division 1 and 2, Class II Division 1 and 2, and Class III. The assembly also provides NEMA protection across 4, 7, 3R, 4X, 12, 3, and 9, ensuring robust performance in demanding environments.
Maintenance can be supported by standard breather and drain features and a corrosion-resistant epoxy-coated finish. Replacement parts, including a flange gasket kit (IF1616) and other service sheets, are available to simplify field service and extend product life without major downtime.
The combination of corrosion-resistant copper-free aluminum construction, epoxy powder coating, and comprehensive hazardous-location ratings reduces maintenance intervals, protects critical motor loads, and minimizes unscheduled downtime. The device’s compatibility with existing gear and its robust enclosure ratings contribute to lower total cost of ownership over the equipment’s life.