Eaton EBY2672 Portable Cord Connector - Explosion-Proof

Part Number: EBY2672
Manufacturer
Eaton Crouse-Hinds
Part number
EBY2672

Quick Summary

EBY2672 portable cord connector is a rugged termination device for non-armoured tray cables used in hazardous locations. Installation teams often struggle with preserving enclosure integrity and safe cable entry in Class I/II environments, especially under demanding conditions. The connector meets NEC/CEC requirements and carries NEC hazardous ratings of Class I, Division 1 and Class II, Division 1, ensuring compliance in mixed hazardous zones. Its explosion-proof design prevents ignition and its aluminum housing offers lightweight durability. With a 3/4 in NPT gland and a compact footprint, it simplifies field mounting while maintaining weather and dust resistance. This combination supports faster assemblies, lower maintenance costs, and safer, compliant wiring in process plants and mining environments.

Product Information

Extended Description

EBY2672 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EBY portable cord connector, Non-armoured and tray cable, Aluminum, Outer sheath min/max: 0.250-0.437", Explosionproof, 3/4" NPT
Product Name
Eaton Crouse-Hinds series EBY portable cord connector
Catalog Number
EBY2672
Product Length/Depth
6.25 in
Product Height
2.06 in
Product Width
2.06 in
Product Weight
0.55 lb
UPC
782274249551
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class II, Division 1
Protection type
Explosion-proof
Cable type
Non-armoured Tray cable
Gland type
Portable cord connector
Thread Size
3/4"
Thread type
NPT
Outer sheath (min/max)
0.250-0.437"
Material
Aluminum
Feature: Explosion-proof protection built into the EBY2672 keeps ignition sources contained in hazardous locations. This reduces the risk of arc-ignition and protects the integrity of the cable termination. Application: ideal for non-armoured tray cables in Class I and II environments where safety is non-negotiable. Business impact: lowers incident potential and minimizes shutdowns due to ignition events, translating to improved uptime. Feature: Aluminum housing provides lightweight durability and corrosion resistance. Business impact: reduces weight burdens during installation and extends service life in outdoor or damp environments. Application: suitable for plant floors, outdoor racks, and exposed conduit systems. Feature: Thread size 3/4 in NPT gland supports standard fittings and fast field assembly. Business impact: accelerates commissioning and simplifies maintenance; Application: automotive, chemical, and mining facilities with common NPT gland inventories. Feature: Non-armoured tray cable compatibility broadens cable sourcing options. Business impact: lowers procurement complexity and stock variety; Application: facilities using common tray cables in hazardous zones. Feature: NEC/CEC compliance with Class I, Division 1 and Class II, Division 1 ratings. Business impact: reduces regulatory risk and speeds project approval; Application: cross-border installations in mixed hazardous locations. Feature: Documentation and installation guides available (IF 389, UL certifications). Business impact: minimizes training time and ensures correct installation; Application: field crews and maintenance teams needing reliable reference material.

Get a Quick Quote for a Eaton Crouse-Hinds EBY2672

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds EBY2672? Enquire Now

FAQs

Yes. The EBY2672 uses a 3/4" NPT gland compatible with common gland fittings and enclosures used in hazardous locations. Its aluminum housing is designed for quick field mounting, maintaining enclosure integrity while meeting NEC/CEC requirements. Proper torque and standard installation practices ensure reliable, safe terminations in Class I/II environments.
The connector supports non-armoured tray cables, with an outer sheath min/max of 0.250" to 0.437". This provides flexibility for typical tray-cable inventories while ensuring a secure, explosion-proof seal. Pairing with standard 3/4" NPT glands simplifies sourcing and reduces downtime during cable terminations.
The EBY2672 is certified for NEC/CEC compliance with hazardous location ratings including Class I, Division 1 and Class II, Division 1. It is intended for Hazardous/Classified Locations and aligns with installation instructions and UL certifications documented in Eaton's specification and catalog pages.
Yes. The EBY2672 is explicitly rated for Class I, Division 1 and Class II, Division 1 environments, making it appropriate for chemical processing, oil & gas, mining, and other hazardous locations. Its explosion-proof construction minimizes ignition risk, supporting safe long-term operation in demanding facilities.
Adopting the EBY2672 reduces ignition risk, improves installation speed and accuracy, and lowers maintenance costs by preserving enclosure integrity. Its compatibility with common tray cables and 3/4" NPT fittings simplifies stocking and field service, delivering faster turnarounds, fewer re-terminations, and improved overall reliability in hazardous-location wiring.