Eaton ECP061204 Enclosure - Hazardous/Classified Locations
Part Number: ECP061204
Manufacturer
Eaton Crouse-Hinds
Part number
ECP061204
Quick Summary
Enclosure protection for electrical gear in hazardous locations is the ECP061204’s core function. Professionals often struggle to meet hazardous-location compliance while maintaining straightforward installation in tight spaces. Key certifications include NEC/CEC compliance and robust NEMA ratings for Class I, II, and III environments, plus IECEx/UL references in official datasheets. This enclosure couples rugged protection with copper-free aluminum construction and bolt-on mounting feet, delivering reliability, easier field installation, and long-term cost savings for industrial plants and utility projects.
Product Information
Extended Description
ECP061204 Eaton Crouse-Hinds: Eaton Crouse-Hinds series ECP enclosure, Rounded cover, 4-5/8" depth, 6" x 12" x 4", Copper-free aluminum, Bolt-on mounting feet
Product Name
Eaton Crouse-Hinds series ECP enclosure
Catalog Number
ECP061204
Product Length/Depth
10.5 in
Product Height
16.5 in
Product Width
6.19 in
Product Weight
32 lb
UPC
662276310766
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2 Class II, Division 1 Class II, Division 2 Class III
NEMA Rating
3 3R 4 7 9
Enclosure size
6" x 12" x 4"
Cover type
Rounded
Depth
4-5/8 in
Material
Copper-free aluminum
Special features
Bolt-on mounting feet
Eaton Crouse-Hinds ECP061204 3D drawing
Crouse-Hinds series ECP Enclosures Brochure
Crouse-Hinds series ECP catalog page
IECEx Certificate of Conformity
IECEx Certificate of Conformity
IECEx Certificate of Conformity
IF 1107 - Mounting Plate Kit
IF 1107 - Mounting Plate Kit
Eaton Specification Sheet - ECP061204
Eaton Specification Sheet - ECP061204
Copper-free aluminum construction reduces weight and corrosion risk while improving long-term durability in harsh environments, translating to lower handling costs and extended service life for your installation. The result is easier transport, faster on-site assembly, and fewer corrosion-related failures in chemical plants, refineries, and mining sites. The rounded cover design enhances gasket effectiveness and simplifies cleaning, improving ingress protection and reducing maintenance downtime during inspections. With a compact 6" x 12" x 4" footprint and a 4-5/8" depth, it fits in tight electrical rooms and outdoor enclosures without sacrificing interior space for components or wiring. Bolt-on mounting feet speed mounting and retrofit with IF mounting kits, minimizing field adaptation and labor costs. The enclosure’s certifications and NEMA ratings provide regulatory confidence, enabling faster project approval and lower risk of non-compliance in hazardous locations. Comprehensive documentation and CAD resources support accurate engineering and accelerated design wins.
Get a Quick Quote for a Eaton Crouse-Hinds ECP061204
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds ECP061204?
Enquire Now
FAQs
The ECP061204 offers bolt-on mounting feet for straightforward installation and field retrofit. It is designed to be compatible with standard mounting accessories such as the IF series mounting plate kits (IF1107 and IF1639), enabling quick upgrades or reconfigurations without extensive drilling or fabrication. This compatibility reduces installation time and boilerplate costs while maintaining a secure, code-compliant assembly.
ECP061204 is certified for Hazardous/Classified Locations with NEC/CEC standards, and it carries NEC hazardous ratings for Class I, Division 1 and 2, Class II Division 1 and 2, and Class III. It also offers NEMA ratings 3, 3R, 4, 7, and 9. These certifications simplify compliance planning by aligning with common industrial and energy-sector requirements and reducing the need for multiple enclosure substitutions.
Yes. The combination of copper-free aluminum, rounded cover, and robust NEMA ratings (3, 3R, 4, 7, 9) makes the ECP061204 well-suited for outdoor or harsh indoor environments commonly found in oil & gas, chemical processing, mining, and water treatment plants. Its hazardous-location approvals further support reliability in challenging operating conditions while maintaining accessibility for maintenance.
The enclosure size is 6" x 12" x 4" with a 4-5/8" depth, and the unit weighs 32 lb. The 10.5" length/depth specification refers to internal layout considerations for components and wiring. These dimensions help engineers size panels, plan cable routing, and optimize mounting location in constrained electrical rooms or outdoor pad applications.
A full set of resources supports design and compliance, including 3D CAD drawings, brochures, and catalog pages, plus IECEx certificate references and installation sheets such as IF1107. Access to these documents accelerates engineering reviews, permits, and on-site assembly, while ensuring that the enclosure configuration remains traceable to the exact model ECP061204.