Quick Summary

ECP101006 is a rugged enclosure designed to protect electrical gear in hazardous locations. Manufacturers often struggle with safe, compliant housings that fit tight spaces and resist harsh industry environments. This unit aligns with NEC/CEC standards, carries NEMA ratings 3, 3R, 4, 7 and 9, and supports Class I, II, and III locations. Constructed from copper-free aluminum with bolt-on mounting feet, it combines lightweight strength with reliable grounding and easy installation. With 10x10x6 inch capacity and a rounded cover, it enables scalable control enclosure deployments across oil and gas, chemical processing, and mining applications. This translates to reduced commissioning time, lower lifecycle costs, and improved regulatory compliance for your projects.

Product Information

Extended Description

ECP101006 Eaton Crouse-Hinds: ECP NEMA 7 ENCLOSURE 10X10X06
Product Name
Eaton Crouse-Hinds series ECP enclosure
Catalog Number
ECP101006
Product Length/Depth
14.66 in
Product Height
14.66 in
Product Width
8.56 in
Product Weight
52 lb
UPC
662276308725
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2 Class II, Division 1 Class II, Division 2 Class III
NEMA Rating
3 3R 4 7 9
Enclosure size
10" x 10" x 6"
Cover type
Rounded
Depth
6-5/8 in
Material
Copper-free aluminum
Special features
Bolt-on mounting feet
Feature: 10x10x6 inch enclosure with a rounded cover. Business Impact: Provides ample internal space for standard control circuits while preserving a compact footprint, simplifying wiring and heatsinking. Application: Ideal for compact hazardous-location control panels in oil and gas, chemical processing, and mining environments. Feature: Copper-free aluminum construction. Business Impact: Delivers corrosion resistance with reduced weight, easing handling, transport, and maintenance budgeting. Application: Suitable for outdoor or chemically aggressive facilities where longevity matters. Feature: NEMA ratings 3, 3R, 4, 7, 9 and area-classified hazardous locations. Business Impact: Ensures compliance with strict safety standards and minimizes unplanned downtime due to enclosure failure. Application: Critical in refinery, chemical processing, and heavy industrial plants requiring robust protection. Feature: Bolt-on mounting feet. Business Impact: Speeds field mounting and improves stability under vibration, reducing install time and grounding variability. Application: Beneficial for retrofit projects or new builds where fast, repeatable mounting is valued. Feature: Compatibility with mounting plate kits and installation docs. Business Impact: Streamlines procurement and reduces design time with ready-to-use mounting plans and CAD resources. Application: Panel builds in global operations, leveraging IF 1107 instruction sheets for consistent installations. Feature: Global certification readiness. Business Impact: Supports IECEx and UL documentation for international projects, expanding market access and compliance confidence. Application: Multinational facilities seeking uniform enclosure standards across sites.

Get a Quick Quote for a Eaton Crouse-Hinds ECP101006

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds ECP101006? Enquire Now

FAQs

The ECP101006 is designed for hazardous-location installations with Class I, II, and III suitability and NEC/CEC compliance. Use the bolt-on mounting feet for secure anchoring and reference the IF 1107 mounting plate kit instructions to simplify field assembly. Ensure proper grounding and follow local codes for safe operation in hazardous zones.
ECP101006 carries NEC/CEC standards alignment and NEMA ratings 3, 3R, 4, 7, and 9, supporting Hazardous/Classified Locations. IECEx certificate references are available in the documentation package, facilitating international compliance. Always verify the specific regional requirements for your project before deployment.
Yes. The enclosure supports mounting plate kits such as IF 1107 and includes installation resources. The bolt-on feet feature aids secure mounting, while the available 3D CAD drawing package helps verify fitment and orientation during design and procurement phases in multi-site deployments.
The enclosure measures 10 inches by 10 inches by 6 inches with a 6-5/8 inch depth, offering a practical interior for standard control panels. It weighs approximately 52 pounds, balancing sturdy protection with manageable handling for installation and maintenance teams.
The copper-free aluminum construction delivers corrosion resistance and lighter weight, reducing maintenance intervals and labor costs. NEMA/Hazardous Location certifications minimize compliance risk, while bolt-on feet and compatible mounting plates shorten installation time, translating into lower total cost of ownership on long-running hazardous-location projects.