Eaton EDS1184 S769 EM-SP Pushbutton Station - Explosionproof
Part Number: EDS1184 S769 EM-SP
Manufacturer
Eaton Crouse-Hinds
Part number
EDS1184 S769 EM-SP
Category
Quick Summary
EDS1184 S769 EM-SP is a hazardous-area pushbutton control station for industrial automation and safety. In challenging sites, operators need rugged protection that won’t slow down maintenance or trigger costly downtime. This unit meets NEC/CEC requirements and UL hazardous-location certifications while delivering strong environmental resistance with NEMA ratings for Class I/II/III environments. Its compact single-gang enclosure, 1/2 in trade size, and maintained mushroom head with lockout and guard support safe, compliant operation. By simplifying panel layouts and minimizing spare parts, the EDS1184 S769 EM-SP provides a clear path to faster commissioning, safer start-ups, and lower total cost of ownership for OEMs and maintainers alike.
Product Information
Extended Description
EDS1184 S769 EM-SP Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS pushbutton control station, With pushbuttons, Emergency, Stop, Feraloy iron alloy, Single circuit universal, 1, Single-gang, 1, Maintained contact mushroom head with lockout and guard, Dead end, 1/2"
Product Name
Eaton Crouse-Hinds series EDS pushbutton control station
Catalog Number
EDS1184 S769 EM-SP
Product Length/Depth
3.5 in
Product Height
5.91 in
Product Width
5.81 in
Product Weight
8.67 lb
UPC
782274153162
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class II, Division 1 Class I, Division 2 Class I, Division 1 Class II, Division 2 Class III
NEMA Rating
7 9 3
Enclosure type
With pushbuttons
Number of gangs
Single-gang
Number of pushbuttons
1
Number of devices
1
Normal position
Single circuit universal
Indicating plate markings
Emergency, Stop
Style
Dead end
Trade size
1/2"
Material
Feraloy iron alloy
Special features
Maintained contact mushroom head with lockout and guard
SP3D Design Package - EDS and EFS Explosionproof Control Stations
EDS/EDSX Hazardous Area Control Stations catalog page
EDS and EFS Explosionproof Pushbutton, Pilot Light, and Selector Switch Control Stations UL certification
EDS and EFS Explosionproof Pushbutton, Pilot Light, and Selector Switch Control Stations UL certification
IF 328 - EDS, EFS, EDSC and EFSC Single- and Two-gang Device Bodies
IF 328 - EDS, EFS, EDSC and EFSC Single- and Two-gang Device Bodies
IF 328 - EDS, EFS, EDSC and EFSC Single- and Two-gang Device Bodies
Eaton Specification Sheet - EDS1184 S769 EM-SP
Feature: Feralo y iron alloy enclosure delivers rugged protection against impact and corrosion, extending service life in harsh environments. Business Impact: reduces replacement costs and unscheduled downtime in oil, gas, and chemical processing facilities. Application: ideal for hazardous locations where equipment must endure heat, moisture, and chemical exposure. Feature: Maintained contact mushroom head with lockout and guard prevents inadvertent energization during servicing. Business Impact: enhances operator safety, regulatory compliance, and incident prevention. Application: emergency stop circuits and start/stop control in hazardous areas. Feature: 1/2 in trade size, single-gang enclosure with a single pushbutton streamlines panel design and material costs. Application: compact control stations on equipment with limited space. Feature: Feraloy iron alloy enclosure plus NEC/CEC compliance and UL hazardous-location ratings with NEMA 7, 9, 3 protection. Business Impact: regulatory peace of mind and reliable performance across jurisdictions. Application: use in Class I/II/III environments, including Division 1 and 2. Feature: Compatibility with SP3D design packages and IF328 installation sheets, plus EDS/EDSX catalog references. Business Impact: speeds engineering, reduces rework, and simplifies procurement. Application: seamless integration into lifecycle from design to commissioning in hazardous settings.
Get a Quick Quote for a Eaton Crouse-Hinds EDS1184 S769 EM-SP
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds EDS1184 S769 EM-SP?
Enquire Now
FAQs
To install the EDS1184 S769 EM-SP, mount it into a compatible single-gang device body and follow IF 328 guidelines for device bodies and mounting. Route the wiring per NEC/CEC standards, connect the pushbutton to the control circuit, and verify the maintained mushroom head with lockout and guard is engaged during maintenance. Use the SP3D design package assets as needed to ensure correct clearances and enclosures.
The EDS1184 S769 EM-SP carries NEC/CEC compliance for hazardous locations, UL certification for explosionproof operation, and a NEMA protection rating of 7, 9, and 3. It supports area classifications for Hazardous/Classified Locations, aligning with Class I, II, and III environments and Division 1 and 2 conditions, providing regulatory confidence across geographies.
Yes. This control station is designed for hazardous locations, with NEC hazardous ratings spanning Class I Division 1 and Class II Division 1, along with other divisions. Its feraloy enclosure and UL explosionproof certification ensure safe operation, while NEMA 7 and 9 ratings provide robust environmental protection, making it suitable for Class I Division 1 applications in oil, gas, and chemical facilities.
Maintenance benefits come from the maintained mushroom head with lockout and guard, reducing accidental energization during resets, and from a durable feraloy iron alloy enclosure that resists wear in harsh sites. The compact 1/2 in trade size simplifies access, while compatibility with standard device bodies minimizes spare parts and training requirements, leading to quicker fault isolation and faster resets after alarms.
The EDS1184 S769 EM-SP is supported by SP3D design packages for explosionproof control stations and installation sheets such as IF 328. This integration allows engineers to model the station accurately, order correct EDS/EDSX catalog pages, and follow installation instructions efficiently, reducing design iteration time and ensuring correct enclosure and wiring layouts for hazardous-area applications.