Eaton EDS2190 S111 Pushbutton Control Station - 600 Vac
Part Number: EDS2190 S111
Quick Summary
EDS2190 S111 Pushbutton Control Station is a robust solution for hazardous-area equipment in industrial automation. Operators often contend with unreliable control stations in harsh environments, which can lead to safety gaps and downtime. This unit delivers explosion-proof housing and a front-operated emergency STOP to improve operator safety and shutdown reliability. Certified for NEC/CEC compliance and hazardous locations, it supports safer installations and easier audits. By combining rugged construction with a compact single-gang footprint, it reduces panel space, simplifies wiring, and lowers total cost of ownership for industrial facilities facing demanding safety and compliance requirements.
Product Information
Extended Description
EDS2190 S111 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS pushbutton control station, With pushbuttons, Feraloy iron alloy, Two circuit universal, 2, Single-gang, 2, Emergency "STOP" front-operated red mushrooon button, Dead end, 3/4", 600 Vac
Product Name
Eaton Crouse-Hinds series EDS pushbutton control station
Catalog Number
EDS2190 S111
Product Length/Depth
3.5 in
Product Height
5.91 in
Product Width
5.81 in
Product Weight
2 lb
UPC
782274521824
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class II, Division 2 Class II, Division 1 Class I, Division 2 Class III
NEMA Rating
9 7 3
Enclosure type
With pushbuttons
Voltage rating
600 Vac
Number of gangs
Single-gang
Number of pushbuttons
2
Number of devices
2
Normal position
Two circuit universal
Style
Dead end
Trade size
3/4"
Material
Feraloy iron alloy
Special features
Emergency "STOP" front-operated red mushrooon button
SP3D Design Package - EDS and EFS Explosionproof Control Stations
EDS/EDSX Hazardous Area Control Stations catalog page
EDS and EFS Explosionproof Pushbutton, Pilot Light, and Selector Switch Control Stations UL certification
EDS and EFS Explosionproof Pushbutton, Pilot Light, and Selector Switch Control Stations UL certification
IF 372 - EDS Notice
IF 372 - EDS Notice
IF 372 - EDS Notice
Eaton Specification Sheet - EDS2190 S111
600 Vac rating with 2 pushbuttons in a single-gang enclosure delivers dual-circuit control in a compact footprint, reducing panel space and installation time while maintaining reliable performance in hazardous locations. This translates to measurable efficiency gains and easier wiring, especially in retrofit projects where space is at a premium and downtime is costly. The Feraloy iron alloy construction provides superior mechanical strength and resistance to corrosion and wear, extending service life in demanding environments such as oil & gas, chemical processing, and mining. The emergency STOP front-operated red mushroom button enhances machine guarding and compliance with safety standards, enabling quick, visible shutdown to minimize risk and potential injury. With 3/4" trade size and 600 Vac rating, installation is straightforward in existing control panels and new builds alike, improving consistency across facilities. The two-device configuration and two pushbuttons support flexible control schemes, reducing the need for additional components and associated wiring, which lowers overall project cost and maintenance overhead. Trust in NEC/CEC compliance and Hazardous/Classified Locations approvals to simplify procurement and regulatory reviews, while the compact form factor supports standard DIN-rail or surface-mounted installations, enabling easy integration with nearby sensors, pilot lights, and controllers.
Get a Quick Quote for a Eaton Crouse-Hinds EDS2190 S111
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds EDS2190 S111?
Enquire Now
FAQs
The EDS2190 S111 is a 1-gang, two-pushbutton control station rated for 600 Vac and designed for Hazardous/Classified Locations. Install in a compliant enclosure with appropriate sealing and conduits per NEC/CEC guidelines. Use instruction sheets IF 372 and IF 328 as references for mounting, wiring torque, and field wiring practices. Ensure correct terminal identification for the two devices and verify the front-operated emergency STOP button is accessible for immediate shutdown. Adhere to local safety standards and UL certifications during assembly.
EDS2190 S111 carries NEC/CEC standards alignment and Hazardous/Classified Locations area classification. It is listed for Class I, Division 1, Class II, Division 2, Class II, Division 1, Class I, Division 2, and Class III, with a NEMA Rating of 9, 7, 3. These certifications indicate suitability for explosive atmospheres and rugged industrial environments, reducing regulatory risk and ensuring safe operation in oil & gas, chemical processing, and mining facilities.
The unit supports two pushbuttons and two devices within a single-gang enclosure, rated at 600 Vac. This configuration enables dual-circuit control from one compact station, simplifying wiring and reducing panel footprint. Its two-pushbutton arrangement supports common interlock or-start/stop implementations, while the 3/4" trade size allows compatibility with standard control housings and knockouts, improving install efficiency in new builds and retrofits alike.
Yes. The EDS2190 S111 is part of the Eaton Crouse-Hinds EDS family of hazardous-area control stations designed for consistent integration with similar devices such as EDSX units. Its 1-gang, 2-device configuration and standard 3/4" trade size streamline replacement, maintenance, and upgrades within existing installations. When expanding a system, you can maintain uniformity of wiring practices, mounting depth, and sealing requirements across stations to simplify commissioning and spare-part inventory.
The front-operated emergency STOP button provides immediate, visible shutdown capability, a critical safety feature in high-risk environments. The rugged Feraloy iron alloy enclosure resists wear and corrosion, reducing maintenance cycles in harsh settings. Certification alignment with NEC/CEC and UL listings simplifies audits and compliance management, while the compact single-gang footprint reduces panel rework and inventory complexity, delivering lower total cost of ownership over the life of the installation.