Eaton EDS2192 S153 Pushbutton Station - Hazardous Locations

Part Number: EDS2192 S153
Eaton Crouse-Hinds logo
Manufacturer
Eaton Crouse-Hinds
Part number
EDS2192 S153

Quick Summary

EDS2192 S153 Pushbutton Station is a rugged control device designed to start and stop equipment in hazardous locations. Engineers frequently encounter pushbutton assemblies that lack proper lockout provisions or fail to meet demanding safety standards, leading to downtime and regulatory risk. This unit aligns with NEC/CEC requirements and carries UL explosionproof certifications, while its robust housing delivers reliable performance in Class I and Class II environments, including Class III considerations. With a compact single-gang footprint and two pushbuttons, it streamlines panel design and reduces spare parts, improving maintenance efficiency. By pairing durable materials with clear labeling and compliant construction, it supports safer, more predictable operation in hazardous-area control stations and other critical applications.

Product Information

Extended Description

EDS2192 S153 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS pushbutton control station, With pushbuttons, Feraloy iron alloy, Two circuit universal, 2, Single-gang, 2, Lockout provision, Dead end, 3/4"
Product Name
Eaton Crouse-Hinds series EDS pushbutton control station
Catalog Number
EDS2192 S153
Product Length/Depth
3.5 in
Product Height
5.91 in
Product Width
5.81 in
Product Weight
8.24 lb
UPC
782274522197
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2 Class II, Division 1 Class II, Division 2 Class III
NEMA Rating
3 7 9
Enclosure type
With pushbuttons
Number of gangs
Single-gang
Number of pushbuttons
2
Number of devices
2
Normal position
Two circuit universal
Style
Dead end
Trade size
3/4"
Material
Feraloy iron alloy
Special features
Lockout provision
Two pushbuttons and two devices provide clear, tactile control with minimal wiring complexity. Business Impact: reduces panel wiring time and potential wiring errors, boosting installation efficiency in hazardous-area control stations. Application: suitable for compact, single-gang enclosures in chemical plants and oil refineries. Feature: 3/4 inch trade size and single-gang footprint streamline mounting in crowded panels. Business Impact: saves cabinet space and accelerates field installation, lowering labor costs. Application: new installations and retrofits in processing facilities where space is at a premium. Feature: Feraloy iron alloy housing with dead end and lockout provision. Business Impact: enhances durability and worker safety by preventing restart during maintenance, reducing risk of injury. Application: hazardous locations with frequent lockout/tagout requirements across mining and chemical plants. Feature: NEC/CEC compliance, UL explosionproof certification, and NEMA ratings 3, 7, 9. Business Impact: ensures regulatory compliance and reliable operation in Class I/II/III environments, reducing audit findings and commissioning time. Application: explosive atmospheres, offshore platforms, and rugged industrial sites. Feature: Installation resources including IF 328 instruction sheets and SP3D designs. Business Impact: shortens engineering time and ensures correct mounting, simplifying procurement and installation. Application: system integrator projects and equipment upgrades across process industries. Feature: Normal position two-circuit universal with dead-end style. Business Impact: supports versatile control schemes and future expansion without replacing hardware. Application: machinery requiring flexible signaling in hazardous areas.

Get a Quick Quote for a Eaton Crouse-Hinds EDS2192 S153

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds EDS2192 S153? Enquire Now

FAQs

For hazardous-location installs, ensure a single-gang enclosure fits the panel and observe the 3/4" trade size. Use the included installation guidance and IF 328 sheets to confirm proper mounting, seal integrity, and lockout provisions. The device's NEC/CEC compliance and UL explosionproof ratings support safe commissioning in Class I/II/III environments.
Yes. The EDS2192 S153 is configured as a two-device, two-pushbutton setup with a two-circuit universal arrangement. This enables independent start/stop signaling while maintaining a compact, single-gang form factor suitable for space-constrained panels in hazardous areas.
The unit is NEC/CEC compliant, UL explosionproof certified, and rated for hazardous locations with Class I, Division 1 and 2, Class II, Division 1 and 2, and Class III environments. It also carries NEMA ratings 3, 7, and 9, making it suitable for a broad range of industrial installations.
Absolutely. Its rugged Feraloy iron alloy housing, lockout provision, and explosionproof UL ratings are designed for oil and gas environments. The two-pushbutton configuration supports standard control logic, while NEC/CEC compliance and NEMA ratings simplify regulatory review and commissioning in these facilities.
The durable construction, lockout capability, and clear labeling reduce maintenance downtime and the risk of accidental restarts. With fewer replacement parts due to a robust enclosure and standardized components, you’ll see lower lifecycle costs and faster repair times, improving overall plant availability and safety in hazardous environments.