Eaton EDS2192 SA S769 Pushbutton Station - Hazardous Areas

Part Number: EDS2192 SA S769
Eaton Crouse-Hinds logo
Manufacturer
Eaton Crouse-Hinds
Part number
EDS2192 SA S769

Quick Summary

EDS pushbutton control station delivers compact dual-button control for hazardous area equipment in industrial automation. This design tackles common downtime and maintenance headaches by providing rugged, code-compliant hardware that withstands tough environments. It carries NEC/CEC conformity and hazardous-location ratings, including Class I, II, III in-division classifications and a robust NEMA rating, giving you reliable operation in explosion-prone spaces. The copper-free aluminum enclosure and 600 Vac capability support safe, long-life control in demanding plants, while its single-gang, 3/4" trade size footprint simplifies panel integration. For procurement teams, this translates to safer, compliant control stations that reduce installation time and maintenance costs without compromising performance.

Product Information

Extended Description

EDS2192 SA S769 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS pushbutton control station, With pushbuttons, Copper-free aluminum, Two circuit universal, 2, Single-gang, 2, Maintained contact mushroom head with lockout and guard, Dead end, 3/4", 600 Vac
Product Name
Eaton Crouse-Hinds series EDS pushbutton control station
Catalog Number
EDS2192 SA S769
Product Length/Depth
3.5 in
Product Height
5.91 in
Product Width
5.81 in
Product Weight
3.55 lb
UPC
662276194328
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class II, Division 2 Class I, Division 2 Class I, Division 1 Class III Class II, Division 1
NEMA Rating
9 3 7
Enclosure type
With pushbuttons
Voltage rating
600 Vac
Number of gangs
Single-gang
Number of pushbuttons
2
Number of devices
2
Normal position
Two circuit universal
Style
Dead end
Trade size
3/4"
Material
Copper-free aluminum
Special features
Maintained contact mushroom head with lockout and guard
Feature: Two pushbuttons and two devices in a single-gang, 3/4in enclosure. Benefit: Enables compact control for two circuits, reducing panel depth and wiring complexity while improving operator reliability in hazardous locations. Application: Suitable for dual-stop/start interlocks on conveyors or pumps in chemical plants. Feature: Copper-free aluminum construction. Benefit: Weight reduction and corrosion resistance in harsh environments, lowering installation effort and lifecycle costs. Application: Outdoor or chemically challenging facilities where enclosure integrity matters. Feature: 600 Vac voltage rating and dead end, with two-circuit universal normal position. Benefit: Supports high-power control and versatile wiring, delivering consistent performance across multiple machine types. Application: Heavy-duty motors and lighting control in hazardous zones. Feature: Maintained contact mushroom head with lockout and guard. Benefit: Prevents accidental operation and provides clear lockout/tagout compliance, boosting operator safety and regulatory adherence. Application: Maintenance procedures and safety interlocks in critical equipment. Feature: NEC/CEC compliance and Hazardous/Classified Locations area classification with NEMA 9 3 7 rating. Benefit: Ensures global regulatory readiness and dependable protection against ignition sources in explosion-prone environments. Application: Oil & gas, petrochemical, and mining facilities requiring certified control stations. Feature: Catalog pages, installation instructions, and SP3D design package availability. Benefit: Accelerates engineering workups, reduces misconfigurations, and streamlines procurement through readily accessible design data. Application: Project design validation and downstream installation planning.

Get a Quick Quote for a Eaton Crouse-Hinds EDS2192 SA S769

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds EDS2192 SA S769? Enquire Now

FAQs

The EDS2192 SA S769 uses a single-gang, 3/4 inch trade size enclosure designed for hazardous locations. It features copper-free aluminum housing and a dead-end style with two pushbuttons and two devices, suitable for Class I, II, III divisions 1 and 2. This configuration enables compact, code-compliant mounting in control panels and field enclosures.
The maintained contact mushroom head with lockout and guard provides a positive, always-on or off state, preventing accidental resets or restarts. This supports strict lockout/tagout procedures, reduces operator errors during maintenance, and improves overall safety in hazardous-area equipment control.
Yes. The unit complies with NEC/CEC standards and is rated for Hazardous/Classified Locations, including Class I, II, III in both Division 1 and Division 2, with a NEMA rating of 9 3 7. This alignment ensures regulatory conformity across North American installations and supports safer, code-compliant operation.
Installation resources include IF 899 instruction sheets for EDSX, EDS, EFS, DSDX and DSD control stations, SP3D design packages for EDS and EFS, and the catalog pages detailing hazardous-area control stations. These materials facilitate correct wiring, assembly, and integration into explosion-proof control systems.
Copper-free aluminum reduces weight and improves corrosion resistance, lowering handling effort and maintenance costs over the life of the unit. The robust construction, coupled with hazardous-location ratings and lockout features, translates to lower downtime and faster repairs, delivering measurable total cost of ownership savings for facilities with demanding service conditions.