Eaton Crouse-Hinds EDS2299 P24 - Hazardous Locations
Part Number: EDS2299 P24
Quick Summary
EDS manual motor starter control station is designed to safely start and stop motors in hazardous locations. In many plants, wiring complexity and equipment downtime challenge reliability and maintenance budgets. This solution combines NEC/CEC compliance with UL certifications for US and Canada, ensuring safe operation in classified areas. The unit also streamlines installation through a compact two-gang enclosure, a 3/4 inch hub, and integrated 1 hp capability, reducing panel space and wiring time. By choosing rugged Feraloy iron alloy construction with a built-in Allen Bradley heater, you gain resilience against moisture and temperature swings. For engineers seeking robust, compliant motor control, the EDS2299 P24 delivers proven performance with minimal risk.
Product Information
Extended Description
EDS2299 P24 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS manual motor starter control station, Single-pole, With switch, 1 HP, With one 3/4" hub, Feraloy iron alloy, Two-gang, With 3.32A Allen Bradley heater, Dead end, 3/4"
Product Name
Eaton Crouse-Hinds series EDS manual motor starter control station
Catalog Number
EDS2299 P24
Product Length/Depth
7.19 in
Product Height
5.91 in
Product Width
5.06 in
Product Weight
15.29 lb
UPC
662276331952
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class III Class II, Division 1 Class II, Division 2 Class I, Division 2 Class I, Division 1
NEMA Rating
3 9 7
Enclosure type
With switch
Number of gangs
Two-gang
Configuration
Single-pole
Style
Dead end
Trade size
3/4"
Horsepower
1 hp
Hub style
With one 3/4" hub
Material
Feraloy iron alloy
Special features
With 3.32A Allen Bradley heater
EDS Series Explosionproof Motor Starter Control Stations catalog page
EDS Explosionproof Motor Starter Control Stations UL certification
EDS Explosionproof Motor Starter Control Stations UL certification
IF 372 - EDS Notice
IF 372 - EDS Notice
IF 372 - EDS Notice
Eaton Specification Sheet - EDS2299 P24
Feature: Two-gang, single-pole manual motor starter with a switch and 1 hp rating. Business impact: Delivers compact, code-compliant motor control that minimizes panel footprint and wiring complexity, reducing installation time and potential miswiring. Application: Ideal for small-to-medium motors in hazardous locations where space is at a premium and reliability matters. Feature: Feraloy iron alloy enclosure and rugged construction. Business impact: Provides corrosion and impact resistance in harsh environments, lowering maintenance costs over the life of the installation. Application: Chemical processing, oil and gas, or mining applications in Class I/II/III areas. Feature: With one 3/4" hub and 3/4" trade size, dead-end, two-gang, with switch. Business impact: Simplifies conduit routing and wiring, supports quick field wiring, and aligns with standard enclosures. Application: Plant floor motor control stations, pump starts, conveyors. Feature: 3.32A Allen Bradley heater integration. Business impact: Reduces nuisance tripping, prevents condensation in cold environments, improves reliability. Application: Environments with temperature fluctuations and exposure to moisture. Feature: NEC/CEC compliance, UL certifications for US/Canada, and hazardous area ratings. Business impact: Compliance assurance reduces regulatory risk and speeds approvals during audits. Application: Installations in hazardous/classified locations like refineries, chemical plants. Feature: Documentation and installation resources, including IF 372 notices and Eaton spec sheet. Business impact: accelerates commissioning, reduces field questions, improves technician onboarding. Application: Projects with strict installation standards and cross-team collaboration.
Get a Quick Quote for a Eaton Crouse-Hinds EDS2299 P24
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds EDS2299 P24?
Enquire Now
FAQs
Install the EDS2299 P24 in a two-gang enclosure with the 3/4" hub, following NEC/CEC guidelines for Class I/II/III divisions. Ensure UL certification compliance for US/Canada and use appropriate conduit and wiring practices. Refer to IF 372 notices and the Eaton specification sheet during setup to reduce commissioning time and avoid wiring errors.
The unit is a single-pole, two-gang manual motor starter with a 1 hp rating and a 3/4" trade size hub. It features a dead-end configuration and includes a 3/4" hub. Construction uses Feraloy iron alloy and it comes with a 3.32A Allen Bradley heater for performance stability in varying temperatures.
Yes. The EDS2299 P24 is designed for Hazardous/Classified Locations and carries NEC/CEC standards with UL certifications for US and Canada, making it appropriate for oil & gas, chemical processing, and similar environments requiring explosionproof motor control.
It carries NEC/CEC compliance, Hazardous Location area classifications, and UL certifications for the US and Canada. The device is rated for Class I, II, III locations and is suitable for use in Division 1 and Division 2 environments, aligning with typical hazardous-location mandates.
The two-gang, compact design reduces panel footprint and wiring time, cutting installation labor. Rugged Feraloy construction plus an integrated heater lowers downtime from condensation and arc-related issues, improving uptime. UL/NEC/CEC compliance simplifies audits and reduces regulatory risk, delivering a faster time-to-savings on projects.