Eaton EDS315 SA Pushbutton Station - Hazardous Locations

Part Number: EDS315 SA
Eaton Crouse-Hinds logo
Manufacturer
Eaton Crouse-Hinds
Part number
EDS315 SA

Quick Summary

EDS315 SA pushbutton control station is designed for hazardous locations where reliable local control is essential. Operators and maintenance teams often contend with corroded enclosures, dust ingress, and downtime in explosive atmospheres. This unit meets NEC/CEC standards and hazardous-location ratings, including Class I, Division 1 and 2, Class II, Division 1 and 2, and a NEMA 3, 7, 9 enclosure, providing robust protection for demanding environments. The copper-free aluminum construction paired with a compact single-gang footprint simplifies installation and service, while delivering two pushbuttons and two devices in a 1" trade-size package rated for up to 600 Vac. Designed for start/stop and signaling tasks in industrial plants, it supports reliable operation with lower total-cost-of-ownership.

Product Information

Extended Description

EDS315 SA Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS pushbutton control station, With pushbuttons, Copper-free aluminum, Two circuit, 2, Single-gang, 2, Dead end, 1", 600 Vac
Product Name
Eaton Crouse-Hinds series EDS pushbutton control station
Catalog Number
EDS315 SA
Product Length/Depth
3.5 in
Product Height
5.91 in
Product Width
5.81 in
Product Weight
3.79 lb
UPC
782274522098
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2 Class II, Division 1 Class II, Division 2 Class III
NEMA Rating
3 7 9
Enclosure type
With pushbuttons
Voltage rating
600 Vac
Number of gangs
Single-gang
Number of pushbuttons
2
Number of devices
2
Normal position
Two circuit
Style
Dead end
Trade size
1"
Material
Copper-free aluminum
Copper-free aluminum enclosure reduces corrosion risk and weight, extending service life in chemical processing, oil and gas, and mining environments. This construction translates to lower maintenance costs and faster field swaps, minimizing downtime during repairs and upgrades in hazardous areas. Two pushbuttons and two devices in a single-gang body offer clear local control for start/stop sequences and signaling, while the 1" trade size keeps panel depth compact. This combination improves operator ergonomics and wiring density, enabling easier fault tracing and quicker commissioning on routine maintenance. 600 Vac rating supports common plant circuits, reducing the need for adapters or rewiring during system upgrades, and preserves safety margins in demanding installations. NEC/CEC compliance and hazard-area ratings (Class I, II, III, Div 1 and 2) along with NEMA 3, 7, 9 protection provide documented safety and reliability for chemical plants, refineries, and offshore installations. Installation efficiency is boosted by documented resources such as IF 328 instruction sheets and SP3D design packages, and by compatibility with standard single-gang device bodies. These assets shorten procurement-to-installation cycles and support accurate field planning. The unit’s lightweight 3.79 lb mass and copper-free aluminum construction help avoid material compatibility issues in sensitive systems, while its compact footprint facilitates swift upgrades and routine maintenance.

Get a Quick Quote for a Eaton Crouse-Hinds EDS315 SA

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds EDS315 SA? Enquire Now

FAQs

For proper installation, use the single-gang EDS315 SA in standard enclosures designed for hazardous locations and observe the 1" trade size footprint. Refer to the IF 328 and SP3D design package resources for mounting dimensions, wiring diagrams, and torque recommendations. Ensure wiring practices meet NEC/CEC requirements and that seals remain intact to preserve NEMA 3/7/9 protections.
EDS315 SA is rated for 600 Vac operation and accommodates two pushbuttons across two devices in a single-gang body. It carries NEC/CEC compliance and hazardous-location ratings, including Class I, Division 1 and 2, Class II, Division 1 and 2, plus Class III, along with a NEMA rating of 3, 7, 9. These certifications support safe operation in chemical, oil/gas, and mining environments.
Yes. The copper-free aluminum enclosure, 600 Vac rating, and Hazardous/Classified Locations certification suite (Class I/II/III Div 1/2) make the EDS315 SA well-suited for oil and gas, chemical processing, and other demanding industrial processes. Its two pushbuttons and two devices in a compact footprint support local control tasks like start/stop and signaling with reliable performance in harsh environments.
The EDS315 SA complies with NEC/CEC standards and hazardous-location classifications, including Class I, Division 1 and 2, Class II, Division 1 and 2, Class III, plus a NEMA 3, 7, 9 enclosure. This regulatory coverage ensures safety, reliability, and compatibility with a wide range of hazardous-area installations found in processing plants and refineries.
The EDS315 SA reduces maintenance costs through a corrosion-resistant copper-free aluminum enclosure and a rugged hazardous-location build, leading to fewer replacements and longer service life. Its compact single-gang design simplifies installation, minimizes wiring complexity, and supports faster commissioning, delivering lower total cost of ownership in environments where downtime is expensive and regulatory compliance is essential.