Eaton Crouse-Hinds EDS3155 Pushbutton Station - Hazardous

Part Number: EDS3155
Manufacturer
Eaton Crouse-Hinds
Part number
EDS3155

Quick Summary

EDS3155 is a pushbutton control station designed for hazardous-location control in demanding industrial environments. It provides a rugged, reliable operator interface that minimizes downtime in explosive atmospheres. With NEC/CEC compliance and hazardous-location ratings, it reduces procurement risk and accelerates approval cycles. The single-gang, two-pushbutton design fits compact panels, while the Feraloy iron alloy enclosure delivers durable service in harsh conditions. Certified for Class I, II, and III locations and protected by NEMA 3, 7, and 9 ratings, it supports safe, compliant operation across oil, gas, mining, and chemical facilities. This translates into safer starts and stops and lower maintenance costs, making it a practical choice for industrial control in challenging environments.

Product Information

Extended Description

EDS3155 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS pushbutton control station, With pushbuttons, Feraloy iron alloy, Two circuit, 2, Single-gang, 2, Dead end, 1", 600 Vac
Product Name
Eaton Crouse-Hinds series EDS pushbutton control station
Catalog Number
EDS3155
Product Length/Depth
3.5 in
Product Height
5.91 in
Product Width
5.81 in
Product Weight
8.59 lb
UPC
782274764030
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2 Class II, Division 1 Class II, Division 2 Class III
NEMA Rating
3 7 9
Enclosure type
With pushbuttons
Voltage rating
600 Vac
Number of gangs
Single-gang
Number of pushbuttons
2
Number of devices
2
Normal position
Two circuit
Style
Dead end
Trade size
1"
Material
Feraloy iron alloy
Feature: Feraloy iron alloy enclosure provides explosion-resistant protection. Business Impact: Enhances operator safety and equipment resilience in flammable atmospheres, reducing incident risk and unplanned downtime. Application: ideal for chemical processing, oil and gas, mining, and other hazardous environments where rugged control stations are essential. Feature: 600 Vac voltage rating with two pushbuttons and two devices in a single-gang body. Business Impact: simplifies wiring and reduces panel footprint, cutting installation time and material costs. Application: motor control and circuit isolation tasks in hazardous locations, where clean, reliable control is critical. Feature: Compact dimensions 3.5 in depth, 5.91 in height, 5.81 in width; single-gang, 1 in trade size. Business Impact: predictable fit in retrofits and new builds, enabling faster panel design and reduced customization. Application: control stations adjacent to limited space in process skids, switchgear closets. Feature: NEC/CEC compliance and hazardous-location ratings including Class I/II/III and NEMA 3/7/9. Business Impact: ensures regulatory alignment, simplifies procurement, and minimizes third-party validation. Application: utility and process industries that require rigorous certification for hazardous-area equipment. Feature: Pre-engineered for reliability with standard installation resources such as SP3D design package, catalogue page, and instruction sheets. Business Impact: reduces design risk and speeds deployment by providing ready-to-use references and 3D models. Application: engineering teams integrating EDS3155 into control panels and enclosures. Feature: With pushbuttons included, two-pole arrangement and dead-end style suit start/stop functions from a single-gang assembly. Business Impact: simplifies operator interaction, minimizes misoperation risk, and reduces panel wiring. Application: starting conveyors, pumps, and fans in hazardous process lines.

Get a Quick Quote for a Eaton Crouse-Hinds EDS3155

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds EDS3155? Enquire Now

FAQs

The EDS3155 is designed for single-gang installations with a 1" trade size, accommodating two pushbuttons and two devices in a compact 3.5" depth. It fits standard hazardous-area enclosures and panel layouts, enabling straightforward retrofits. The unit’s dimensions and mounting pattern simplify wiring schematics and reduce field modification time while maintaining NEC/CEC compliance.
The EDS3155 operates at 600 Vac and features two pushbuttons across two devices in a two-circuit, single-gang arrangement. Normal operation is two circuits in a dead-end, 1" trade size. This configuration supports motor and circuit-control tasks in hazardous environments, reducing the need for auxiliary accessories while ensuring reliable isolation and control performance.
Industry-standard applications include chemical processing, oil and gas facilities, mining operations, and other settings with hazardous atmospheres. The unit’s Feraloy iron alloy enclosure and explosion-proof construction deliver reliable operation for start/stop control of pumps, conveyors, and fans in locations requiring compliance with Class I/II/III Hazardous Locations and NEMA 3/7/9 protection.
The EDS3155 carries NEC/CEC standards with hazardous-location ratings across Class I, Division 1 and 2, Class II, Division 1 and 2, and Class III. It also meets NEMA ratings 3, 7, and 9, and is intended for Hazardous/Classified Locations. These certifications facilitate regulatory approval and ensure safe operation in harsh environments.
Durable construction with Feraloy iron alloy, combined with explosion-proof design and NEC/CEC compliance, reduces downtime and maintenance frequency in hazardous facilities. Its compact form and two-pushbutton configuration minimize wiring, panel space, and spare parts. Businesses gain predictable deployment timelines, fewer field modifications, and improved total cost of ownership across multinational sites.