Eaton EDS3192 S769 Pushbutton Station - Hazardous Locations
Part Number: EDS3192 S769
Quick Summary
EDS pushbutton control station enables safe start/stop signaling in hazardous industrial environments. For engineers upgrading control panels in chemical plants or refineries, reliability and compliance are critical pain points. This unit meets NEC/CEC requirements and hazardous-location ratings such as Class I, Division 1 & 2; Class II, Division 1 & 2; Class III, with a rugged NEMA 9/7/3 enclosure. By combining explosion-proof construction with a compact, single-gang footprint, it simplifies installation and improves maintenance across 600 Vac systems, aligning with project timelines and lifecycle costs for industrial facilities. Its maintained contact mushroom head with lockout enhances operator safety, while the 1" trade-size design fits existing panels. This makes it a practical choice for hazardous-location control stations in oil, gas, chemical, and mining sectors.
Product Information
Extended Description
EDS3192 S769 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS pushbutton control station, With pushbuttons, Feraloy iron alloy, Two circuit universal, 2, Single-gang, 2, Maintained contact mushroom head with lockout and guard, Dead end, 1", 600 Vac
Product Name
Eaton Crouse-Hinds series EDS pushbutton control station
Catalog Number
EDS3192 S769
Product Length/Depth
3.5 in
Product Height
6.03 in
Product Width
5.81 in
Product Weight
8.4 lb
UPC
662276206885
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 2 Class II, Division 1 Class II, Division 2 Class I, Division 1 Class III
NEMA Rating
9 7 3
Enclosure type
With pushbuttons
Voltage rating
600 Vac
Number of gangs
Single-gang
Number of pushbuttons
2
Number of devices
2
Normal position
Two circuit universal
Style
Dead end
Trade size
1"
Material
Feraloy iron alloy
Special features
Maintained contact mushroom head with lockout and guard
SP3D Design Package - EDS and EFS Explosionproof Control Stations
EDS/EDSX Hazardous Area Control Stations catalog page
EDS and EFS Explosionproof Pushbutton, Pilot Light, and Selector Switch Control Stations Canadian certification
EDS and EFS Explosionproof Pushbutton, Pilot Light, and Selector Switch Control Stations Canadian certification
IF 899 - EDSX, EDS, EFS, DSDX and DSD Control Stations
IF 899 - EDSX, EDS, EFS, DSDX and DSD Control Stations
IF 899 - EDSX, EDS, EFS, DSDX and DSD Control Stations
Eaton Specification Sheet - EDS3192 S769
Feature: Compact single-gang enclosure with two pushbuttons. Benefit: Reduces panel depth and wiring complexity, enabling easier retrofits and faster installation in space-constrained control panels. Application: Hazardous-location automation in chemical processing or refinery lines. Feature: Feraloy iron alloy construction and explosion-proof design. Benefit: Delivers rugged durability in harsh environments, lowering maintenance costs and extending service life in demanding facilities. Application: Continuous operation in mining, oil & gas, and petrochemical plants. Feature: Maintained contact mushroom head with lockout and guard. Benefit: Helps prevent accidental operation, improving operator safety and enabling safer lockout/tagout procedures. Application: Safety-critical start/stop controls in hazardous locations. Feature: 600 Vac rating with two devices and two circuits universal. Benefit: Supports standard industrial control circuits without needing extra devices, reducing panel count and wiring complexity. Application: Main control circuits for motors, pumps, and conveyors in hazardous areas. Feature: Hazardous/Classified Locations certifications with NEC/CEC compliance and NEMA ratings. Benefit: Regulatory alignment minimizes project risk, speeds approvals, and ensures equipment suitability for Class I/II/III environments. Application: Projects across oil, gas, chemical processing, mining, and energy sectors. Feature: Compatibility with Eaton SP3D packages, IF899 installation sheets, and catalog pages. Benefit: Streamlines design and procurement, enabling rapid integration into pre-engineered control stations. Application: Engineering, procurement, and construction (EPC) projects and maintenance refurbishments.
Get a Quick Quote for a Eaton Crouse-Hinds EDS3192 S769
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds EDS3192 S769?
Enquire Now
FAQs
The EDS3192 S769 is a single-gang, 1" trade-size pushbutton station designed for hazardous locations. Its compact footprint fits many standard explosion-proof enclosures, simplifying retrofits and new installs in Class I/II/III environments. With two pushbuttons and a robust enclosure, it reduces wiring runs and panel depth while maintaining compliance with NEC/CEC and NEMA ratings. Always verify enclosure rating and mounting provisions for your exact panel model.
This control station is certified for hazardous/classified locations under NEC/CEC standards, with NEC hazardous ratings including Class I, Division 2 and Class I, Division 1, plus Class II and Class III designations. It carries NEMA ratings 9, 7, and 3, and is suitable for hazardous environments requiring explosion-proof, durable construction. Area classification is Hazardous/Classified Locations, ensuring regulatory alignment for critical process control.
Yes. The unit is rated for 600 Vac and configured as a single-gang enclosure with two devices (two pushbuttons). It uses a 1" trade size and features a dead-end style with a maintained-contact mushroom head. Mounting is designed for integration into standard hazardous-location control panels, and it supports two-circuit universal operation, enabling straightforward wiring and panel compatibility.
The control station features a maintained contact mushroom head with lockout and guard, preventing accidental actuation and enabling safe lockout/tagout procedures. Its rugged Feraloy iron alloy construction enhances durability in harsh environments, reducing wear and downtime. The unit’s hazard-rated design and NEC/CEC compliance also simplify safety inspections and regulatory audits.
Useful resources include the SP3D Design Package for EDS and EFS Explosionproof Stations, the EDS/EDSX catalog page, and installation sheets IF 899 for EDSX, EDS, EFS, DSDX, and DSD Control Stations. These assets, along with the Eaton specification sheet for EDS3192 S769, provide wiring diagrams, dimensions, and mounting recommendations to support engineering and procurement teams.