Eaton EDS3230 SA Snap Switch Control Station - Hazardous/Classified Locations

Part Number: EDS3230 SA
Eaton Crouse-Hinds logo
Manufacturer
Eaton Crouse-Hinds
Part number
EDS3230 SA

Quick Summary

EDS3230 SA is a snap switch control station for hazardous locations in industrial automation. In harsh environments, panel wiring must be reliable, compact, and easy to service without sacrificing safety. This unit carries NEC/CEC compliance and hazardous-location ratings, including Class I Division 1 and 2, Class II, and Class III, plus sturdy NEMA 3, 7, 9 enclosure protections. Its copper-free aluminum housing and a two-gang, three-pole design with a 1-inch hub deliver robust performance with straightforward installation. For engineers and procurement teams, this combination translates to reduced commissioning time, fewer field reworks, and dependable operation across shift cycles while meeting stringent safety standards.

Product Information

Extended Description

EDS3230 SA Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS snap switch control station, 20A, With switch, With one 1" hub, Copper-free aluminum, 2, Two-gang, Three-pole, 2, 120-277V, Dead end, 3-way, 1", 120-277 Vac
Product Name
Eaton Crouse-Hinds series EDS snap switch control station
Catalog Number
EDS3230 SA
Product Length/Depth
5.06 in
Product Height
5.875 in
Product Width
7.19 in
Product Weight
7.68 lb
UPC
782274534077
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2 Class II, Division 1 Class II, Division 2 Class III
NEMA Rating
3 7 9
Enclosure type
With switch
Trade size
1"
Number Of Poles
Three-pole
Switch function
3-way
Number of gangs
Two-gang
Style
Dead end
Voltage rating
120-277 Vac
Amperage Rating
20A
Hub style
With one 1" hub
Number of devices
2
Number of pushbuttons
2
Primary voltage range
120-277V
Material
Copper-free aluminum
Two-gang, three-pole configuration combines two pushbuttons and a 3-way switch into a single compact assembly, reducing panel depth and wiring complexity. This feature translates to faster panel assembly and lower field labor costs during maintenance. Rated 20A at 120-277V supports common control circuits and lighting in industrial facilities, reducing the need for multiple devices and simplifying spares. The copper-free aluminum enclosure offers superior corrosion resistance in chemical and damp environments while maintaining a manageable weight for field service. Installation is streamlined by the standard 1" hub, easing cable entry and routing in tight panels and conduits. Hazardous area ratings, NEC/CEC compliance, and NEMA 3, 7, 9 protections ensure regulatory alignment and safer operation in oil, gas, and chemical plants. Documentation and installation resources, including IF328 instruction sheets and Eaton catalogs, support quick commissioning and routine maintenance, minimizing downtime and non-production time. In practice, facilities gain measurable uptime, reduced risk, and a clear path to compliant upgrades for legacy control stations in hazardous locations.

Get a Quick Quote for a Eaton Crouse-Hinds EDS3230 SA

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds EDS3230 SA? Enquire Now

FAQs

The EDS3230 SA is designed for Hazardous/Classified Locations and carries NEC/CEC compliance with Class I Division 1 and 2, Class II Division 1 and 2, and Class III ratings. It features a 1-inch hub, a copper-free aluminum enclosure, and a two-gang, three-pole layout, making it suitable for 120–277V control circuits up to 20A. Ensure adherence to site wiring practices and local codes during panel assembly.
This unit is rated at 20A and 120–277V AC, supporting a two-device, two-pushbutton, three-pole (3-way) switch arrangement in a two-gang enclosure with a single 1" hub. The dead-end style enclosure and copper-free aluminum construction optimize durability and wiring accessibility for complex control loops in harsh conditions.
Yes. Its Hazardous/Classified Locations rating, NEC/CEC compliance, and NEMA ratings 3, 7, and 9 make it appropriate for chemical, oil, and gas environments. The copper-free aluminum enclosure resists corrosive atmospheres, while the two-gang, three-pole design supports essential process control functions with reliable operation.
The EDS3230 SA aligns with NEC/CEC standards and hazardous-area classifications (Class I Division 1 and 2; Class II Division 1 and 2; Class III). It also carries NEMA ratings 3, 7, and 9, confirming suitability for damp, hazardous, and potentially explosive environments and helping ensure regulatory compliance during audits.
Eaton provides installation sheets and technical catalog pages for the EDS3230 SA, including IF328 instruction sheets for EDS/EDSX device bodies and the Eaton specification sheet. These resources enable faster commissioning, easier troubleshooting, and clearer guidance for field technicians during upgrades or replacements in hazardous locations.