Quick Summary

EDS pushbutton control station from Eaton Crouse-Hinds provides a rugged operator interface for hazardous-area machinery in industrial facilities. Many teams struggle with retrofits, costly re-wiring, and downtime when upgrading control stations for code-compliant explosion protection. This model carries NEC/CEC compliance and hazardous-location ratings, including Class I, Division 1/2 and Class II/III environments, plus robust enclosure protection. The through-feed, single-gang design with a 1/2" trade size simplifies field wiring, reduces panel space needs, and speeds installation. With a Feraloy iron alloy enclosure and 600 Vac rating, it supports reliable operation, minimizes maintenance costs, and helps you meet stringent safety and regulatory requirements while protecting personnel and assets.

Product Information

Extended Description

EDSC1184 GB Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS pushbutton control station, With pushbuttons, Feraloy iron alloy, Single circuit universal, 1, Single-gang, 1, Suitable for Class I, Division 1, Group B, Through feed, 1/2", 600 Vac
Product Name
Eaton Crouse-Hinds series EDS pushbutton control station
Catalog Number
EDSC1184 GB
Product Length/Depth
3.5 in
Product Height
6.72 in
Product Width
5.81 in
Product Weight
8.18 lb
UPC
782274896335
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 2 Class III Class II, Division 1 Class I, Division 1 Class II, Division 2
NEMA Rating
9 7 3
Enclosure type
With pushbuttons
Voltage rating
600 Vac
Number of gangs
Single-gang
Number of pushbuttons
1
Number of devices
1
Normal position
Single circuit universal
Style
Through feed
Trade size
1/2"
Material
Feraloy iron alloy
Special features
Suitable for Class I, Division 1, Group B
Feature → Business Impact → Application: Exposed in hazardous environments, the Feraloy iron alloy enclosure provides superior abrasion and heat resistance, reducing replacement costs and downtime; ideal for chemical processing and oil & gas facilities that demand durable, explosion-protected equipment. Feature → Through-feed mounting and 1/2" trade size enable flexible wiring configurations, shortening install times and enabling easier upgrades in existing panels; applicable to retrofits and new installations where space is constrained. Feature → 600 Vac voltage rating with single-circuit universal operation supports standard automation logic and minimizes compatibility issues across machines; streamlines procurement and reduces spare parts inventory for plant-wide control stations. Feature → One pushbutton, single-gang enclosure delivers concise operator control and reduced ergonomic footprint; supports fast commissioning and straightforward maintenance in harsh plants. Feature → NEC/CEC compliance and hazard-area certifications, including Class I Division 1/2 and Class II/III, plus NEMA 9, 7, 3 ratings, provide regulatory confidence and safer audits; crucial for facilities undergoing rigorous inspections or multi-site deployments. Feature → Through-feed design and readily available installation resources, such as SP3D packages and installation sheets, simplify project planning, integration, and training; enhances field productivity and reduces risk during expansion projects.

Get a Quick Quote for a Eaton Crouse-Hinds EDSC1184 GB

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds EDSC1184 GB? Enquire Now

FAQs

Yes. The EDSC1184 GB is designed with a 1/2" trade size and through-feed capability, enabling flexible wiring in hazardous locations. The unit is rated for 600 Vac and comes in a single-gang enclosure with one pushbutton, matching typical control station configurations used in Class I Division 1 installations while maintaining compliance and ease of wiring during retrofit or new builds.
The EDSC1184 GB confirms NEC/CEC compliance and hazardous-location ratings appropriate for Hazardous/Classified Locations. It supports Class I Division 1 and Division 2, Class II Division 1 and 2, and Class III, along with NEMA ratings 9, 7, and 3. UL certification is documented for explosion-proof operation, ensuring regulatory readiness and smoother audits for global facilities.
Its Feraloy iron alloy enclosure delivers ruggedness and resistance to harsh conditions, reducing wear and corrosion. The through-feed design simplifies field wiring, enabling quicker replacements and reconfigurations. With a 600 Vac rating and a compact single-gang form factor, it minimizes space, assembly time, and downtime during line upgrades or emergency maintenance in hazardous plants.
A comprehensive set of resources supports deployment, including SP3D Design Package for EDS/EFS control stations, a dedicated catalog page, UL certification reports, IF 372 installation sheets, and a detailed Eaton specification sheet. These materials help engineers plan, model, and execute installations efficiently while ensuring compliance with safety standards.
The ROI arises from reduced retrofit time, fewer non-compliant reworks, and lower maintenance costs due to the rugged, explosion-proof design. By standardizing on NEC/CEC-compliant, hazardous-location-rated stations with simple through-feed wiring and a compact footprint, projects benefit from faster commissioning, fewer unplanned outages, and safer operator interfaces in demanding plants.