Eaton Crouse-Hinds EDSC21093 G30 - Hazardous Locations
Part Number: EDSC21093 G30
Quick Summary
Eaton Crouse-Hinds EDSC21093 G30 is a manual motor starter control station for hazardous-location motors. Engineers rely on a compact, switch-enabled unit to start and protect industrial machines in demanding environments. Farmers, miners, and plant operators often grapple with reliability, safety, and code compliance when wiring motor controls in classified areas. This model delivers NEC/CEC compliance with hazardous-location ratings (Class I and II, Division 1 and 2; Class III) and NEMA protection ratings, helping teams pass audits and avoid costly rework. The through-feed enclosure and 3/4-inch hubs simplify wiring, reduce install time, and support scalable motor control architectures. In practice, it pairs well with 1 hp motors in compact control stations, enabling safer, faster maintenance and greater uptime.
Product Information
Extended Description
EDSC21093 G30 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS manual motor starter control station, Single-pole, With switch, 1 HP, With two 3/4" hubs, Feraloy iron alloy, Single-gang, With 5.90A GE heater, Through feed, 3/4"
Product Name
Eaton Crouse-Hinds series EDS manual motor starter control station
Catalog Number
EDSC21093 G30
Product Length/Depth
3.5 in
Product Height
6.72 in
Product Width
5.06 in
Product Weight
8.02 lb
UPC
782274443652
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class II, Division 1 Class III Class II, Division 2 Class I, Division 1 Class I, Division 2
NEMA Rating
7 9 3
Enclosure type
With switch
Number of gangs
Single-gang
Configuration
Single-pole
Style
Through feed
Trade size
3/4"
Horsepower
1 hp
Hub style
With two 3/4" hubs
Material
Feraloy iron alloy
Special features
With 5.90A GE heater
EDS Series Explosionproof Motor Starter Control Stations catalog page
EDS Explosionproof Motor Starter Control Stations Canadian certification
EDS Explosionproof Motor Starter Control Stations Canadian certification
IF 372 - EDS Notice
IF 372 - EDS Notice
IF 372 - EDS Notice
Eaton Specification Sheet - EDSC21093 G30
Through-feed single-pole configuration with a single-gang enclosure and two 3/4 in hubs simplifies wiring and panel space. Business impact: faster installation, reduced wiring errors, and scalable control layouts for compact cabinets in hazardous locations. Application: ideal for short-run conveyors or pump packages in chemical plants or oil & gas facilities. 1 hp horsepower rating aligns with common motor sizes, delivering reliable starting torque while maintaining a compact footprint. Business impact: lower spare parts and simplified procurement, with predictable performance. Application: supports standard motor loads in hazardous-area panels where space is constrained. Feraloy iron alloy construction provides rugged durability and improved heat resistance in harsh environments. Business impact: longer service life, reduced maintenance cycles, and lower total ownership cost. Application: suitable for continuous duty in explosion-risk areas without compromising enclosure integrity. Special features include a 5.90A GE heater to prevent condensate formation in damp or cold locations. Business impact: improved reliability during start-up and reduced nuisance trips. Application: enhances performance in cooler, humid industrial settings. NEC/CEC compliance, Hazardous/Classified Locations area classification, and NEMA ratings 7, 9, and 3. Business impact: expedites safety audits, ensures regulatory alignment, and mitigates risk of non-conformance. Application: ideal for multi-shift operations in petrochemical, mining, and refining environments. Overall installation advantages include a through-feed design and two 3/4 in hubs, enabling easy field wiring and straightforward updates to evolving control schemes. Business impact: reduced commissioning time and improved uptime, with clear pathways for future expansion.
Get a Quick Quote for a Eaton Crouse-Hinds EDSC21093 G30
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds EDSC21093 G30?
Enquire Now
FAQs
The EDSC21093 G30 is designed for hazardous-area use with Class I/II/III ratings and NEC/CEC compliance. It features a single-pole configuration in a single-gang enclosure with through-feed wiring and 3/4 in hubs, enabling straightforward retrofits or new installs in classified locations.
The starter provides 1 hp motor protection and switching, through-feed enclosure with 3/4 in hubs, a single-pole configuration, and a Feraloy iron alloy enclosure. It includes a GE heater rated at 5.90A to prevent condensation, and carries NEC/CEC compliance with Class I, II, and III ratings.
Yes. The single-gang, through-feed design with two 3/4 in hubs allows easy integration into compact control cabinets. Its through-feed wiring and switch-enabled enclosure reduce wiring modifications and fit well with 1 hp motors in classified locations.
Cite Hazardous/Classified Locations area classification, NEC/CEC standards, and NEMA ratings 7, 9, 3. The unit also reflects Class I, Division 1 and Division 2, Class II, Division 1 and 2, and Class III ratings as applicable, along with its Canadian certification/UL documentation.
Consult the IF 372 EDS notice and the Eaton specification sheet for maintenance guidance, part compatibility, and installation instructions. Support materials include the catalog page and certification reports, which help verify compliance and serviceability in demanding environments.