EDS motor starter is a compact control station for starting and protecting motors in hazardous locations. For engineers and procurement teams, reliable, code-compliant starters reduce downtime and redesign risk. This unit carries NEC/CEC certifications with Class I, Division 1 and Class II, Division 1 ratings, plus a NEMA 9 enclosure, enabling safe operation in explosive atmospheres. Designed for through-feed service in a single-gang housing with 3/4 inch hubs and a 1 HP motor, it streamlines wiring and future upgrades. By choosing an Eaton Crouse-Hinds solution, you gain proven compatibility with standard GE heater and replacement parts, supporting maintenance planning and long-term total cost of ownership.

Product Information

Extended Description

EDSC21093 G37 GB Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS manual motor starter control station, Single-pole, With switch, 1 HP, With two 3/4" hubs, Feraloy iron alloy, Single-gang, With 10.60A GE heater; Class I, Division 1, Group B, Through feed, 3/4"
Product Name
Eaton Crouse-Hinds series EDS manual motor starter control station
Catalog Number
EDSC21093 G37 GB
Product Length/Depth
3.5 in
Product Height
6.72 in
Product Width
5.06 in
Product Weight
7.4 lb
UPC
662276708136
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2 Class III Class II, Division 2 Class II, Division 1
NEMA Rating
9 7 3
Enclosure type
With switch
Number of gangs
Single-gang
Configuration
Single-pole
Style
Through feed
Trade size
3/4"
Horsepower
1 hp
Hub style
With two 3/4" hubs
Material
Feraloy iron alloy
Special features
With 10.60A GE heater; Class I, Division 1, Group B
Feature: Hazardous location certifications (Class I, Division 1; Class II, Division 1; NEC/CEC) → Business impact: Enables safe operation in explosive atmospheres, reduces compliance risk, and simplifies site approvals → Application: Oil & gas, chemical processing, mining, and other classified locations. Feature: Compact single-gang, through-feed enclosure with switch → Business impact: Saves panel space, accelerates panel build, and simplifies wiring diagrams → Application: Control stations in limited footprint installations and retrofit projects. Feature: Feraloy iron alloy housing with 10.60A GE heater → Business impact: Durable construction and reliable heater-assisted performance minimize nuisance trips and cold-start faults → Application: Harsh environments with wide temperature ranges and high ambient demands. Feature: Electrical spec set: 1 HP, 3/4" trade size, two 3/4" hubs, single-pole, through-feed → Business impact: Standard motor compatibility and straightforward wiring reduce design changes and installation time → Application: conveyors, pumps, and small drives in hazardous areas. Feature: Certifications and standards alignment (NEC/CEC; NEMA 9, 7, 3) → Business impact: Regulatory compliance and proven enclosure protection support audits and maintenance planning → Application: Industrial facilities requiring rigorous electrical protection and documented conformity.

Get a Quick Quote for a Eaton Crouse-Hinds EDSC21093 G37 GB

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds EDSC21093 G37 GB? Enquire Now

FAQs

The EDSC21093 G37 GB is designed as a single-pole, through-feed control station in a single-gang enclosure with two 3/4" hubs. It wires cleanly into standard low-voltage circuits and accepts common GE heaters, helping integrators avoid custom interconnects. This compatibility speeds up commissioning and minimizes the risk of mis-matched components during retrofit projects in hazardous locations.
This unit carries NEC/CEC compliance with hazardous-location ratings including Class I, Division 1 and Class II, Division 1, plus a NEMA rating of 9, 7, and 3. The area classification is suitable for Hazardous/Classified Locations, making it suitable for oil and gas, chemical processing, and mining environments while meeting regulatory and safety requirements.
Yes. The EDSC21093 G37 GB is explicitly designed for through-feed operation and includes two 3/4" hubs. This configuration supports straightforward wiring and easy integration with conveyors, pumps, or small motors up to 1 HP, reducing enclosure footprint and simplifying field installations in hazardous areas.
The integrated 10.60A GE heater helps maintain consistent internal temperatures, reducing the risk of nuisance tripping due to cold starts and condensation in demanding environments. This improves uptime, extends service intervals, and lowers maintenance costs by stabilizing starting performance in varying ambient conditions.
Expect reduced downtime from reliable explosion-protected operation, easier sourcing of replacement parts due to standard GE heater compatibility, and streamlined maintenance records thanks to documented NEC/CEC and NEMA ratings. These factors collectively contribute to lower lifecycle costs and improved asset availability in hazardous facilities.