Quick Summary

The Eaton Crouse-Hinds EDSC21093 G38 SA is a manual motor starter control station for hazardous-location motor control in industrial environments. In harsh facilities, startup downtime and safety risk drive costs; this unit integrates switching, protection, and a heater in a rugged enclosure to reduce those barriers. Certified for NEC/CEC with Hazardous/Classified Location ratings and a NEMA 7/3/9 enclosure, it meets stringent industry codes while enduring tough operating conditions. This control-station supports through-feed wiring, two 3/4-inch hubs, a 1 hp motor rating, and copper-free aluminum construction for long-term reliability and cost efficiency. Designed for industrial buyers, it also reduces spare-part variety by delivering a single, compatible solution for motor control stations.

Product Information

Extended Description

EDSC21093 G38 SA Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS manual motor starter control station, Single-pole, With switch, 1 HP, With two 3/4" hubs, Copper-free aluminum, Single-gang, With 11.40A GE heater, Through feed, 3/4"
Product Name
Eaton Crouse-Hinds series EDS manual motor starter control station
Catalog Number
EDSC21093 G38 SA
Product Length/Depth
3.5 in
Product Height
6.72 in
Product Width
5.06 in
Product Weight
8.02 lb
UPC
662276065475
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 2 Class I, Division 1 Class II, Division 1 Class II, Division 2 Class III
NEMA Rating
7 3 9
Enclosure type
With switch
Number of gangs
Single-gang
Configuration
Single-pole
Style
Through feed
Trade size
3/4"
Horsepower
1 hp
Hub style
With two 3/4" hubs
Material
Copper-free aluminum
Special features
With 11.40A GE heater
Feature: Single-pole, single-gang enclosure with a built-in switch simplifies installation in tight spaces. Business Impact: Reduces panel footprint, speeds wiring, and minimizes risk of miswiring during upgrades. Application: Ideal for hazardous-location motor control stations in confined panels where reliability and quick commissioning matter. Feature: Through-feed design with two 3/4-inch hubs enables scalable wiring. Business Impact: Supports clean, fault-tolerant circuits and faster expansion without replacing the starter. Application: Use in line and load wiring for compact control stations in hazardous environments. Feature: Copper-free aluminum enclosure provides corrosion resistance and lighter weight. Business Impact: Lowers lifecycle costs through reduced maintenance and safer handling during installations. Application: Suitable for chemical plants, offshore facilities, and other harsh installations. Feature: Built-in 11.40A GE heater protects against condensation. Business Impact: Maintains reliability and reduces nuisance trips in temperature swings. Application: Critical in outdoor or unconditioned spaces where humidity affects starter operation. Feature: 1 hp rating with NEMA 7/3/9 and NEC/CEC compliance. Business Impact: Ensures regulatory safety and compatibility with small motors while minimizing risk and downtime. Application: For hazardous-area motor control stations in mining, oil and gas, and chemical processing.

Get a Quick Quote for a Eaton Crouse-Hinds EDSC21093 G38 SA

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds EDSC21093 G38 SA? Enquire Now

FAQs

Plan for a compliant mounting surface in Class I/II areas and ensure the enclosure is securely sealed. Verify the single-pole configuration, the two 3/4-inch hubs, through-feed wiring, and proper grounding practices. Document cable routing, strain relief, and ingress protection so field technicians can install quickly while maintaining NEC/CEC compliance.
Through-feed wiring and the two 3/4-inch hubs simplify circuit routing and reduce terminal density, lowering heat buildup and potential wiring errors. The design enables clean trunk lines and scalable expansion for additional devices without replacing the starter. In hazardous environments, this translates to faster commissioning, easier maintenance, and better fault isolation during motor startups.
Yes, it is rated for a 1 hp motor and designed to operate reliably in harsh locations. The enclosure uses copper-free aluminum for corrosion resistance, and a built-in 11.40A GE heater minimizes condensation. The unit's hazardous-location certifications and NEC/CEC compliance provide integrated protection for switches, wiring, and heater during motor operation.
It carries NEC/CEC standards and hazardous location ratings that cover Class I Division 1 and 2, Class II Division 1 and 2, and Class III. The enclosure is rated NEMA 7, 3, 9, providing protection against dust, moisture, and corrosive environments. These certifications help ensure compliance with industrial safety codes and reduce regulatory risk.
Maintenance is minimized by a copper-free enclosure that resists corrosion and a heater that reduces condensation-related downtime. With NEC/CEC compliance and compact through-feed design, installation time is shorter and wiring errors are less likely, contributing to lower labor costs and reduced spare parts. Over time, users typically see improved uptime and predictable maintenance cycles.