Eaton Crouse-Hinds EDSC21094 G25 Motor Starter Control Station - Hazardous/Classified Locations

Part Number: EDSC21094 G25
Eaton Crouse-Hinds logo
Manufacturer
Eaton Crouse-Hinds
Part number
EDSC21094 G25

Quick Summary

EDSC21094 G25 is a rugged motor starter control station for hazardous-location motor control applications. In harsh environments, enclosure integrity and heater reliability are critical to preventing nuisance trips and downtime. It carries NEC/CEC compliance with hazardous-location ratings across Class I, II, and III and ships in a robust NEMA enclosure designed for demanding industrial use. Designed for through-feed wiring and 3/4 in hubs, it offers a compact single-gang footprint with proven compatibility across Eaton Crouse-Hinds products. This combination delivers safer operation, lower maintenance costs, and faster service in process plants, chemical plants, and other facilities where reliability matters most. Engineers benefit from straightforward installation and a reliable heater-equipped design.

Product Information

Extended Description

EDSC21094 G25 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS manual motor starter control station, Two-pole, With switch, 1 HP, With two 3/4" hubs, Feraloy iron alloy, Single-gang, With 3.88A GE heater, Through feed, 3/4"
Product Name
Eaton Crouse-Hinds series EDS manual motor starter control station
Catalog Number
EDSC21094 G25
Product Length/Depth
3.5 in
Product Height
6.72 in
Product Width
5.06 in
Product Weight
8.02 lb
UPC
782274905488
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class III Class II, Division 2 Class II, Division 1 Class I, Division 1 Class I, Division 2
NEMA Rating
9 7 3
Enclosure type
With switch
Number of gangs
Single-gang
Configuration
Two-pole
Style
Through feed
Trade size
3/4"
Horsepower
1 hp
Hub style
With two 3/4" hubs
Material
Feraloy iron alloy
Special features
With 3.88A GE heater
Feraloy iron alloy enclosure delivers rugged durability in explosive atmospheres, reducing corrosion and wear on control hardware. This translates to longer service life in oil, gas, and chemical processing plants, where equipment endures heat, dust, and corrosive vapors. The through-feed design supports easy field routing of power and control conductors, minimizing wiring errors and installation time. Two-pole configuration paired with a 1 HP rating aligns with common industrial motors, reducing the risk of mismatch and oversizing. This simplifies procurement and spare-part planning for maintenance teams, while ensuring reliable starting torque for small drives in conveyors and machine tools. Two 3/4 in hubs allow through-feed wiring directly into the control station, cutting conduit runs and enabling safer, neater panel wiring. In field installations where space is tight, this compact, single-gang enclosure minimizes panel footprint without sacrificing accessibility. A built-in 3.88A GE heater helps prevent condensation inside the enclosure, reducing nuisance trips and protecting contacts in cold climates. This feature lowers maintenance costs by preventing moisture-related faults in rugged sites such as foundries, offshore platforms, or refrigerated facilities. Compliance with NEC/CEC standards and hazardous-location ratings across multiple classes provides compliance assurance for hazardous-zone installations. The enclosure is rated for Hazardous/Classified Locations with a suitable NEMA rating, supporting safe operation in demanding environments. Single-gang enclosure, with 'With switch' configuration and standard trade size of 3/4 in ensures straightforward replacement and compatibility with existing Eaton Crouse-Hinds control lines. Many plants benefit from standardized mounting and quick upgrade paths to higher protection classes.

Get a Quick Quote for a Eaton Crouse-Hinds EDSC21094 G25

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds EDSC21094 G25? Enquire Now

FAQs

Installation should follow NEC/CEC hazardous-location requirements and use the single-gang enclosure with two 3/4 in hubs for through-feed wiring. Ensure the site is classified per the appropriate Hazardous/Classified Location rating and that wiring practices minimize exposure to moisture and dust. The built-in heater helps protect against condensation in cold environments.
Yes. The unit is configured with two 3/4 in hubs and a through-feed wiring style, allowing efficient conductor routing. This design reduces conduit runs, eases installation, and simplifies future maintenance when upgrading or expanding motor control in feed-through panels.
Absolutely. It is a two-pole configuration rated for 1 HP motors, housed in a single-gang enclosure with a through-feed style. The compact 3.5 in depth, 6.72 in height, and 5.06 in width support easy mounting in standard control panels while providing accessible switch operation.
It carries NEC/CEC compliance and Hazardous/Classified Locations ratings, including Class I, Class II, and Class III across divisions. The enclosure features a NEMA rating suitable for harsh environments, with UL certification references available in the product downloads, ensuring regulatory alignment for industrial hazardous-area installations.
The built-in 3.88A GE heater reduces moisture inside the enclosure, lowering the risk of condensation-related faults and nuisance trips. This translates to lower maintenance needs, improved uptime in humid or cold facilities, and longer life for the switching components in rugged industrial environments.