Eaton EDSC21101 W14 Manual Motor Starter Control Station - Hazardous Locations
Part Number: EDSC21101 W14
Quick Summary
The Eaton EDSC21101 W14 manual motor starter control station starts and protects small motors in hazardous locations. Its rugged enclosure and through-feed design minimize miswiring and reduce maintenance downtime. Designed to meet NEC/CEC standards, it carries Hazardous/Classified Locations ratings and UL certifications for reliable field service. With a compact single-gang footprint, two 3/4 in hubs, a 1 hp motor rating, and a built-in 1.51 A heater, installation is straightforward and scalable. This combination supports safer startup sequences and aligns with industrial automation best practices for explosion-protected control stations. Its compatibility with existing Eaton and third-party motor controls adds long-term value for automation teams.
Product Information
Extended Description
EDSC21101 W14 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS manual motor starter control station, Single-pole, With switch, 1 HP, With two 3/4" hubs, Feraloy iron alloy, Single-gang, With 1.51A Cutler Hammer heater, Through feed, 3/4"
Product Name
Eaton Crouse-Hinds series EDS manual motor starter control station
Catalog Number
EDSC21101 W14
Product Length/Depth
3.5 in
Product Height
6.72 in
Product Width
5.06 in
Product Weight
8.02 lb
UPC
662276638563
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class II, Division 2 Class I, Division 2 Class III Class II, Division 1
NEMA Rating
7 9 3
Enclosure type
With switch
Number of gangs
Single-gang
Configuration
Single-pole
Style
Through feed
Trade size
3/4"
Horsepower
1 hp
Hub style
With two 3/4" hubs
Material
Feraloy iron alloy
Special features
With 1.51A Cutler Hammer heater
EDS Series Explosionproof Motor Starter Control Stations catalog page
EDS Explosionproof Motor Starter Control Stations UL certification
EDS Explosionproof Motor Starter Control Stations UL certification
IF 372 - EDS Notice
IF 372 - EDS Notice
IF 372 - EDS Notice
Eaton Specification Sheet - EDSC21101 W14
Single-pole through-feed configuration with two 3/4 in hubs reduces wiring complexity and speeds panel assembly, cutting installation time on projects with limited access. Fewer wiring mistakes mean faster commissioning and fewer rework cycles, delivering measurable labor savings. This setup is well suited for 1 hp motor starts in hazardous locations where space is at a premium and reliability matters. Rugged Feraloy iron alloy enclosure provides resistance to mechanical impact and chemical exposure, extending service life in harsh plants. The heavy-duty material supports reliable operation in environments with dust, steam, and corrosive vapors, reducing maintenance intervals. This is particularly beneficial for mining, chemical processing, and oil and gas facilities. Built-in 1.51 A Cutler Hammer heater maintains safe operating temperature, preventing nuisance trips and lockups in cold conditions. The heater integration simplifies installation by eliminating separate thermostats and wiring. For operators, that means fewer unplanned shutdowns and improved uptime in outdoor or unheated cabinets. Compact single-gang footprint with 3/4 in trade size simplifies retrofits and reduces enclosure footprint. Its through-feed design supports straightforward wiring from feeders and loads, which helps preserve existing conduit layouts. Engineers can meet space constraints while preserving compatibility with a wide range of motor control schemes. Compliance and certification are built in with NEC/CEC standards, UL listings, and hazardous location ratings such as Class I Division 1. This supports easier audits, safer installations, and faster approvals for regulated facilities. The unit also ships with Eaton and third-party compatibility, enabling seamless integration into legacy control schemes and future upgrades.
Get a Quick Quote for a Eaton Crouse-Hinds EDSC21101 W14
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds EDSC21101 W14?
Enquire Now
FAQs
Is this unit compatible with common electrical enclosures and wiring schemes? The EDSC21101 W14 is a single-gang, through-feed control station designed for 3/4" hubs and 1 hp motors. It fits standard hazardous-location panel layouts and supports both Eaton and third-party motor controls, minimizing rework during retrofits and enabling straightforward integration into existing control architectures.
The device is rated for 1 hp motors and features a built-in 1.51 A heater to maintain safe temperatures in cool environments. It complies with NEC/CEC requirements and carries hazardous location approvals (Class I, Division 1 and similar ratings). For operations in harsh environments, this translates to reliable startup sequences and reduced nuisance trips.
Best-suited for hazardous locations in oil & gas, chemical processing, mining, and heavy industry, the EDSC21101 W14 supports explosion-proof motor control for 1 hp motors. Its rugged enclosure and through-feed wiring are ideal for retrofit projects and new installs where space and compliance are critical.
This control station is certified under NEC/CEC standards with Hazardous/Classified Locations ratings and UL listings. It also carries NEMA ratings for rugged enclosures. These certifications help streamline audits, ensure compliance with regulatory requirements, and support safe operation in demanding industrial environments.
Expect reduced downtime due to a robust Feraloy enclosure, integrated heater, and through-feed wiring that minimizes field wiring errors. Long-term ROI comes from lower maintenance costs, fewer outages, and extended service life in harsh locations, along with compatibility that simplifies future upgrades and spare parts availability.