Eaton EDSC21101 W26 Motor Starter - Hazardous Locations

Part Number: EDSC21101 W26
Eaton Crouse-Hinds logo
Manufacturer
Eaton Crouse-Hinds
Part number
EDSC21101 W26

Quick Summary

EDS manual motor starter control station enables safe single-pole motor control in hazardous locations. Many engineers struggle with hazardous-location compliance, space constraints, and integration with existing control panels. The device carries NEC/CEC compliance and UL listings for hazardous locations, including Class I, II, and III ratings across Division 1 and Division 2. Designed for through-feed, single-gang installation with two 3/4-inch hubs and a 1 HP rating, it reduces wiring time, simplifies maintenance, and supports rugged industrial environments. This combination delivers a compact, compliant solution that fits tightly engineered panels while delivering reliable motor control where it matters most.

Product Information

Extended Description

EDSC21101 W26 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS manual motor starter control station, Single-pole, With switch, 1 HP, With two 3/4" hubs, Feraloy iron alloy, Single-gang, With 4.79A Cutler Hammer heater, Through feed, 3/4"
Product Name
Eaton Crouse-Hinds series EDS manual motor starter control station
Catalog Number
EDSC21101 W26
Product Length/Depth
3.5 in
Product Height
6.72 in
Product Width
5.06 in
Product Weight
8.02 lb
UPC
782274726731
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class II, Division 1 Class III Class II, Division 2 Class I, Division 2 Class I, Division 1
NEMA Rating
9 3 7
Enclosure type
With switch
Number of gangs
Single-gang
Configuration
Single-pole
Style
Through feed
Trade size
3/4"
Horsepower
1 hp
Hub style
With two 3/4" hubs
Material
Feraloy iron alloy
Special features
With 4.79A Cutler Hammer heater
Feature: Explosion-protected enclosure made from a feraloy iron alloy ensures durable construction. Benefit: Increases equipment protection and reduces long-term maintenance costs in harsh environments. Application: Chemical processing and oil & gas facilities where explosion protection is mandatory and downtime is costly. Feature: Through-feed, single-pole configuration with 1 HP capability. Benefit: Streamlines installation, lowers wiring complexity, and improves system uptime through simpler startup sequences. Application: Conveyor belts, pumps, and small-motor drives in manufacturing lines requiring quick, reliable control. Feature: Two 3/4-inch hubs and single-gang footprint. Benefit: Eases panel integration, minimizes space claims, and accelerates retrofits in existing assemblies. Application: Control stations in compact electrical cabinets or safety enclosures. Feature: 4.79A Cutler Hammer heater for thermal protection. Benefit: Reduces nuisance trips and extends motor life by maintaining stable operating temperatures. Application: Motors operating near thermal limits or in variable-load processes. Feature: NEC/CEC compliance with NEC hazardous ratings (Class I/II, Division 1 & 2; Class III). Benefit: Ensures regulatory adherence and safer installations across global facilities. Application: Plants and stations requiring formal electrical-code conformity and premium safety standards.

Get a Quick Quote for a Eaton Crouse-Hinds EDSC21101 W26

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds EDSC21101 W26? Enquire Now

FAQs

The EDSC21101 W26 is designed for hazardous/classified locations with NEC/CEC compliance and UL listings. It features a through-feed, single-pole configuration in a single-gang enclosure with two 3/4-inch hubs, making panel mounting straightforward and compliant with typical installation standards in oil, gas, and chemical processing environments.
Key specs include 1 HP horsepower, through-feed design, single-pole configuration, two 3/4-inch hubs, feraloy iron alloy enclosure, and a 4.79A Cutler Hammer heater. It is built for hazardous locations and conforms to NEC/CEC standards, supporting reliable operation in harsh industrial settings.
Yes. The EDSC21101 W26 carries UL certifications for use in hazardous locations, and its NEC hazardous rating covers Class I, Division 1 and related classifications. This ensures safe operation, regulatory compliance, and suitability for demanding environments such as oil, gas, and chemical processing facilities.
Its single-gang, through-feed design with two 3/4-inch hubs simplifies wiring and reduces panel space. The 1 HP rating matches common motor loads, while the feraloy body provides rugged protection, enabling faster retrofits and more reliable startup sequences in dense control panels.
The built-in heater helps prevent nuisance trips by stabilizing operating temperatures, extending motor life and reducing unplanned downtime. The combination of rugged enclosure material and certified hazardous-location ratings offers ongoing safety compliance, lowering long-term maintenance costs in hazardous environments.