Eaton Crouse-Hinds EDSC21101 W34 manual motor starter control station is a compact, single-pole solution for hazardous-location equipment. Engineers often wrestle with safe installation, matching the right starter to motor loads, and maintaining regulatory compliance in harsh environments. It carries NEC/CEC compliance, UL certification for hazardous locations, and a NEMA-rated enclosure (3, 7, 9) to withstand demanding service. Pairing with a 1 hp rating, through-feed configuration, and two 3/4 in hubs, it delivers reliable, code-ready control. In addition, the integrated heater and feraloy iron alloy body simplify field wiring and reduce maintenance downtime. This combination supports faster commissioning and aligns with ongoing safety and reliability programs.

Product Information

Extended Description

EDSC21101 W34 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS manual motor starter control station, Single-pole, With switch, 1 HP, With two 3/4" hubs, Feraloy iron alloy, Single-gang, With 10.30A Cutler Hammer heater, Through feed, 3/4"
Product Name
Eaton Crouse-Hinds series EDS manual motor starter control station
Catalog Number
EDSC21101 W34
Product Length/Depth
3.5 in
Product Height
6.72 in
Product Width
5.06 in
Product Weight
8.02 lb
UPC
782274726274
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class II, Division 2 Class III Class I, Division 1 Class I, Division 2 Class II, Division 1
NEMA Rating
3 7 9
Enclosure type
With switch
Number of gangs
Single-gang
Configuration
Single-pole
Style
Through feed
Trade size
3/4"
Horsepower
1 hp
Hub style
With two 3/4" hubs
Material
Feraloy iron alloy
Special features
With 10.30A Cutler Hammer heater
Feature: Hazardous-location enclosure with NEC/CEC compliance and UL listing. Business Impact: Ensures regulatory compliance, mitigates risk, and simplifies audits. Application: Suitable for Class I/Division 1 environments in chemical plants, refineries, and mining installations that require explosion-protected control stations. Feature: Through-feed single-pole, 3/4 in hub design. Business Impact: Streamlines wiring, enables flexible layout, and reduces panel depth during installation. Application: Ideal for compact control panels and retrofit projects where space is at a premium. Feature: 1 hp rating with a 10.30A Cutler Hammer heater. Business Impact: Provides reliable motor starting and thermal protection, lowering nuisance trips and downtime. Application: Controls small to medium loads in hazardous locations, improving process uptime. Feature: Feraloy iron alloy housing. Business Impact: Delivers rugged durability, corrosion resistance, and long service life in harsh environments. Application: Suitable for oil, gas, and chemical processing plants with aggressive atmospheres. Feature: Hub style with two 3/4 in hubs and single-gang, single-pole configuration. Business Impact: Flexible wiring options and straightforward installation in tight spaces. Application: Commonly used in single-gang control stations on compact motor enclosures in industrial facilities.

Get a Quick Quote for a Eaton Crouse-Hinds EDSC21101 W34

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds EDSC21101 W34? Enquire Now

FAQs

The EDSC21101 W34 is designed for Class I, Division 1 environments and NEC/CEC compliance, with a through-feed configuration and two 3/4 in hubs. Use IF 899 documentation for installation guidance, and follow local electrical codes to ensure proper mounting, wiring, and heater integration for safe operation.
Core specs include a 1 hp rating, single-pole, single-gang configuration, through-feed style, 3/4 in trade size hubs, feraloy iron alloy housing, an integrated 10.30A heater, and a hazardous-location rated enclosure. The unit is NEC/CEC compliant and has a NEMA rating of 3, 7, 9, making it suitable for tough industrial environments.
Yes. The EDSC21101 W34 carries UL certification for hazardous locations and NEC/CEC compliance, supporting safe operation in Class I and Class II environments. This listing helps meet regulatory requirements and simplifies documentation for audits and inspections in plants handling flammable liquids, gases, or dust.
Yes. The EDSC21101 W34 features a through-feed configuration with two 3/4 inch hubs, enabling flexible wiring routes and easier field modification. This design supports compact panel layouts while maintaining reliable electrical connections for motor control in hazardous locations.
The unit minimizes downtime through reliable 1 hp motor starting, integrated heater protection, and durable feraloy housing. UL/NEC compliance reduces regulatory risk, while simplified installation lowers labor costs during commissioning. Overall, expect improved process safety, reduced maintenance frequency, and faster return on investment in tough industrial environments.