Quick Summary

The Eaton EDSC2130 GB snap switch control station provides reliable 20A control in hazardous industrial locations. Operators often struggle with downtime and wiring complexity in Class I environments, making quick, safe installations essential. This unit aligns with NEC/CEC standards and hazardous-area classifications, including Class I, Division 1 and NEMA protection for hazardous environments. With two 3/4" hubs, a single-gang footprint, and a through-feed design, it delivers flexible wiring options and streamlined installation. The rugged Feraloy iron alloy enclosure supports durable operation in demanding conditions, while 120-277V, 3-way switching and three-pole control enable scalable, compliant control of critical equipment in process industries.

Product Information

Extended Description

EDSC2130 GB Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS snap switch control station, 20A, With switch, With two 3/4" hubs, Feraloy iron alloy, 1, Single-gang, Three-pole, 120-277V, Class I, Division 1, Group B, Through Feed, 3-way, 3/4", 120-277 Vac
Product Name
Eaton Crouse-Hinds series EDS snap switch control station
Catalog Number
EDSC2130 GB
Product Length/Depth
5.06 in
Product Height
5.875 in
Product Width
3.5 in
Product Weight
7.28 lb
UPC
782274031941
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class II, Division 2 Class III Class I, Division 2 Class II, Division 1
NEMA Rating
7 3 9
Enclosure type
With switch
Trade size
3/4"
Number Of Poles
Three-pole
Switch function
3-way
Number of gangs
Single-gang
Style
Through feed
Voltage rating
120-277 Vac
Amperage Rating
20A
Hub style
With two 3/4" hubs
Number of devices
1
Primary voltage range
120-277V
Material
Feraloy iron alloy
Special features
Class I, Division 1, Group B
Feature: Hazardous-location rating and compliance → Business Impact: Enables safe operation in Class I, Division 1 environments, reducing risk and avoiding costly non-compliant installations → Application: Oil and gas, chemical processing, mining facilities require NEC/CEC compliant equipment. Feature: Through-feed single-gang enclosure with two 3/4" hubs at 120-277V → Business Impact: Simplifies field wiring, reduces conduit runs, and cuts installation time by streamlining device layout → Application: Control stations in compact electrical rooms and hazardous zones. Feature: Three-pole, 3-way switch with 20A rating → Business Impact: Supports multiple control points and higher-load switching with reliable performance and minimal contact wear → Application: Complex motor control and process interlocks in hazardous plants. Feature: Feraloy iron alloy enclosure → Business Impact: Superior mechanical strength and durability under vibration, corrosion resistance, and long service life → Application: Harsh industrial environments such as refineries and chemical plants. Feature: NEC/CEC standards and NEMA 7/3/9 protection → Business Impact: Ensures regulatory compliance and robust environmental protection, reducing maintenance costs and downtime → Application: Projects requiring certified equipment in hazardous or classified locations. Feature: Hub style and accessories compatibility → Business Impact: Flexible installation with standard conduit connections, speeding commissioning and future upgrades → Application: Retrofit or new-build sites needing adaptable control stations. Feature: Compact dimensions (5.06 in L × 5.875 in H × 3.5 in W) and 7.28 lb weight → Business Impact: Easy integration into existing panels and minimal space impact in control rooms → Application: Retrofit projects where space is at a premium. Feature: Cataloged and documented installation resources (IF328 instruction sheets, datasheets) → Business Impact: Reduced commissioning risk and clearer maintenance guidance → Application: Field service and maintenance teams seeking reliable references.

Get a Quick Quote for a Eaton Crouse-Hinds EDSC2130 GB

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds EDSC2130 GB? Enquire Now

FAQs

EDSC2130 GB is designed for Class I, Division 1 environments with two 3/4" hubs and a through-feed single-gang enclosure. Follow NEC/CEC guidelines, use appropriate gland fittings, and reference IF328 instruction sheets for mounting and wiring to ensure compliant, safe installations.
The unit provides 20A at 120-277V, with a three-pole, 3-way switch configuration and an enclosure that supports through-feed wiring. It is built from Feraloy iron alloy and is rated for hazardous locations per NEC/CEC standards, including Class I, Division 1 and related NEMA protections.
Yes. EDSC2130 GB is a snap switch control station designed to pair with Eaton Crouse-Hinds EDS/EDSX devices, simplifying replacement, upgrades, and field-maintenance while preserving control logic and safety features.
It carries Hazardous/Classified Locations area classification with NEC/CEC standards, and a NEMA rating of 7, 3, 9. The configuration supports Class I, Division 1, Group B fault tolerance and safety in challenging environments.
The rugged enclosure, long service life of Feraloy iron alloy, and built-in wiring flexibility reduce maintenance cycles and downtime. Compatibility with standard installation sheets and availability of catalogs/datasheets support faster commissioning and lower lifecycle costs in hazardous-location projects.