Eaton Crouse-Hinds EDSC215 Pushbutton Station - Hazardous
Part Number: EDSC215
Quick Summary
EDS Crouse-Hinds EDSC215 pushbutton control station enables safe motor control in hazardous locations. For engineers, unreliable stations and noncompliant enclosures drive unnecessary maintenance costs and downtime. This product carries NEC/CEC compliance and hazardous-area ratings (Class I/II/III) along with NEMA 3/7/9 enclosure protection, helping you meet safety standards. With through-feed wiring, two pushbuttons in a single-gang package, you gain streamlined panel layouts and faster installation. In practice, selecting this station reduces field-service visits and lowers lifecycle costs in oil, gas, chemical, and mining environments.
Product Information
Extended Description
EDSC215 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS pushbutton control station, With pushbuttons, Feraloy iron alloy, Two circuit, 2, Single-gang, 2, Through feed, 3/4"
Product Name
Eaton Crouse-Hinds series EDS pushbutton control station
Catalog Number
EDSC215
Product Length/Depth
6.72 in
Product Height
5.81 in
Product Width
3.5 in
Product Weight
8.95 lb
UPC
782274765273
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2 Class II, Division 1 Class II, Division 2 Class III
NEMA Rating
3 7 9
Enclosure type
With pushbuttons
Voltage rating
600 Vac
Number of gangs
Single-gang
Number of pushbuttons
2
Number of devices
2
Normal position
Two circuit
Style
Through feed
Trade size
3/4"
Material
Feraloy iron alloy
SP3D Design Package - EDS and EFS Explosionproof Control Stations
EDS/EDSX Hazardous Area Control Stations catalog page
EDS and EFS Explosionproof Pushbutton, Pilot Light, and Selector Switch Control Stations Canadian certification
EDS and EFS Explosionproof Pushbutton, Pilot Light, and Selector Switch Control Stations Canadian certification
IF 372 - EDS Notice
IF 372 - EDS Notice
IF 372 - EDS Notice
Eaton Specification Sheet - EDSC215
Feature: Feraloy iron alloy enclosure provides rugged protection against impacts and corrosion. Benefit: Extends service life and reduces replacement costs in tough industrial environments. Application: Suitable for chemical plants and mining sites where reliability directly affects production uptime. Feature: Hazardous-location construction aligned with NEC/CEC classifications. Benefit: Improves regulatory compliance and reduces risk of noncompliance penalties, enabling safer operation across facilities. Application: Oil and gas facilities, refineries, and other explosive atmosphere applications. Feature: 600 Vac rating with two pushbuttons and two devices in a single-gang, through-feed design. Benefit: Simplifies control wiring, minimizes enclosure depth, and speeds installation, leading to shorter project timelines. Application: Control stations for motors and feeders in compact panels. Feature: NEMA 3/7/9 protection. Benefit: Robust suitability for outdoor and hazardous indoor environments, lowering enclosure maintenance and weather-related failures. Application: Outdoor substations, chemical plants, and mining sites requiring rugged sealing. Feature: Through-feed wiring and 3/4" trade size for easy integration. Benefit: Reduces field wiring complexity and enables modular upgrades with existing systems. Application: Retrofit projects and new-builds where space and wiring efficiency matter. Industry context: This configuration aligns with typical EDS/EDSX control-station ecosystems, enabling seamless compatibility with Eaton’s explosion-proof control components and installation instructions, supporting faster commissioning and lifecycle reliability.
Get a Quick Quote for a Eaton Crouse-Hinds EDSC215
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds EDSC215?
Enquire Now
FAQs
The EDSC215 is designed as a single-gang through-feed pushbutton station with two devices and two pushbuttons, suitable for Class I/II/III environments. When installing, ensure enclosure mounting in a compliant area, respect the 3/4 inch trade size wiring entry, and follow through-feed wiring practices to minimize penetrations and simplify future upgrades.
EDSC215 operates at 600 Vac with two pushbuttons and two devices in a through-feed, single-gang enclosure. It utilizes a Feraloy iron alloy enclosure and offers NEC/CEC compliance with hazardous-location ratings (Class I, II, III). The unit is designed for robust operation in demanding environments while maintaining safe control of motors and feeders.
Yes. EDSC215 is intended for hazardous/classified locations and offers NEC/CEC compliance with Class I/II/III ratings plus NEMA 3/7/9 protection, making it appropriate for oil & gas, chemical plants, and mining facilities where explosion-protection and weather sealing are critical.
EDSC215 carries NEC/CEC standards for hazardous locations and NEMA ratings 3/7/9, which validate its suitability for explosive atmospheres and harsh environments. These certifications help ensure regulatory compliance, worker safety, and reduced risk during audits and inspections, supporting procurement specifications in regulated industries.
The rugged Feraloy enclosure, fusion-welded integrity, and explosion-proof design reduce field-service events and parts replacement. With a compact single-gang footprint, two pushbuttons, and through-feed wiring, commissioning is faster, downtime is minimized, and lifecycle costs are lowered in facilities with stringent safety and reliability requirements.