Eaton Crouse-Hinds EDSC2184 GB S153 Pushbutton - Hazardous Locations
Part Number: EDSC2184 GB S153
Quick Summary
EDS pushbutton control stations deliver explosion-proof control for hazardous locations in industrial environments. This model helps prevent downtime by offering a rugged, through-feed single-gang solution with a built-in lockout provision. It carries NEC/CEC compliance and supports Class I Division 1, Group B installations along with strong NEMA ratings for reliable operation in tough environments. Operators gain safer start-up, easier maintenance, and longer service life when integrating this station into your control panels. The design pairs with standard EDS/EFS device bodies, delivers 600 Vac capability, and uses a durable Feraloy iron alloy enclosure, making it a solid fit for oil and gas, chemical processing, and other hazardous locations. By selecting this station, you optimize uptime while controlling installation costs and safety risks.
Product Information
Extended Description
EDSC2184 GB S153 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS pushbutton control station, With pushbuttons, Feraloy iron alloy, Single circuit universal, 1, Single-gang, 1, Suitable for Class I, Division 1, Group B, Lockout provision, Through feed, 3/4", 600 Vac
Product Name
Eaton Crouse-Hinds series EDS pushbutton control station
Catalog Number
EDSC2184 GB S153
Product Length/Depth
3.5 in
Product Height
6.72 in
Product Width
5.81 in
Product Weight
8.21 lb
UPC
782274903316
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2 Class II, Division 1 Class II, Division 2 Class III
NEMA Rating
7 9 3
Enclosure type
With pushbuttons
Voltage rating
600 Vac
Number of gangs
Single-gang
Number of pushbuttons
1
Number of devices
1
Normal position
Single circuit universal
Style
Through feed
Trade size
3/4"
Material
Feraloy iron alloy
Special features
Suitable for Class I, Division 1, Group B, Lockout provision
SP3D Design Package - EDS and EFS Explosionproof Control Stations
EDS/EDSX Hazardous Area Control Stations catalog page
EDS and EFS Explosionproof Pushbutton, Pilot Light, and Selector Switch Control Stations Canadian certification
EDS and EFS Explosionproof Pushbutton, Pilot Light, and Selector Switch Control Stations Canadian certification
IF 328 - EDS, EFS, EDSC and EFSC Single- and Two-gang Device Bodies
IF 328 - EDS, EFS, EDSC and EFSC Single- and Two-gang Device Bodies
IF 328 - EDS, EFS, EDSC and EFSC Single- and Two-gang Device Bodies
Eaton Specification Sheet - EDSC2184 GB S153
Feature: Explosion-proof enclosure and 600 Vac rating enable safe control in Hazardous/Classified Locations. Business Impact: Reduces risk of arcing and ignition, ensuring compliant operation in Class I Division 1 environments. Application: Chemical plants and offshore platforms where ignition sources must be controlled. Feature: 1 pushbutton, 3/4 inch trade size, single-gang, through-feed configuration. Business Impact: Streamlines panel design, saves panel space, and simplifies wiring with a compact footprint. Application: Standardized control stations in compact enclosures across FMC/assembly lines. Feature: Feraloy iron alloy construction. Business Impact: Enhances durability and corrosion resistance in harsh environments, lowering maintenance costs. Application: Outdoor or chemically harsh facilities with frequent washdowns. Feature: Lockout provision and safety features. Business Impact: Improves compliance with lockout/tagout protocols, reducing startup risks and improving worker safety. Application: Maintenance shutdowns and safe isolation procedures across process lines. Feature: 600 Vac electrical rating with single device capability. Business Impact: Supports centralized control with reliable electrical performance, reducing the need for multiple feeders. Application: General purpose control stations in hazardous areas using a single pushbutton control element. Feature: Compatibility with single-gang EDS/EFS device bodies and IF328 instruction guidance. Business Impact: Streamlines procurement and installation, ensuring standardization across facilities. Application: New builds or upgrades requiring common device bodies and documented installation practices. Feature: Certifications and compliance (NEC/CEC, NEMA 7, 9, 3). Business Impact: Ensures regulatory adherence and safe operation under diverse environmental conditions. Application: Cross-industry deployments where standardization and certification credibility are critical. Feature: 3/4" trade size and through-feed style. Business Impact: Reduces panel real estate while preserving ease of wiring and maintenance. Application: Compact control stations in limited-space panels or where retrofits are required.
Get a Quick Quote for a Eaton Crouse-Hinds EDSC2184 GB S153
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds EDSC2184 GB S153?
Enquire Now
FAQs
Install as a single-gang, through-feed pushbutton station with a 3/4" trade size. Ensure Class I Division 1 compliance and connect to a 600 Vac supply. Follow IF328 installation guidelines and use compatible device bodies to simplify wiring, reduce panel space, and maintain lockout readiness during maintenance.
It is designed for Hazardous/Classified Locations with NEC/CEC adherence and supports NEC hazardous ratings for Class I, Division 1 and 2, as well as Class II and III where applicable. The enclosure uses a durable Feraloy iron alloy and carries appropriate NEMA ratings to withstand demanding industrial settings.
The station operates at 600 Vac and includes 1 pushbutton with 1 device in a single-gang, 3/4" trade size through-feed design. It is compatible with standard EDS/EFS hazardous-area device bodies and can be integrated into common control panels with minimal wiring changes.
Yes. The unit includes a lockout provision, enabling safe isolation during maintenance or servicing, helping you meet established lockout/tagout procedures and reduce accidental energization.
Resources include IF 328 instruction sheets, SP3D design packages, and the EDS/EDSX hazardous-area control stations catalog page, along with the Eaton specification sheet. These guides support correct mounting, wiring, and compliance documentation for hazardous-location installations.