Eaton Crouse-Hinds EDSC2184 OP Pushbutton Control Station - Hazardous Locations
Part Number: EDSC2184 OP
Quick Summary
Eaton Crouse-Hinds EDSC2184 OP pushbutton control station is a rugged device for hazardous-location machinery control. Operators in explosive or containment-critical environments face downtime and wiring mistakes that slow starts and increase risk. This unit carries NEC/CEC compliance with hazardous area ratings and NEMA protection for reliable service in Class I/II environments and Division 1 and 2 locations. In practice, it simplifies panel wiring with a single-gang, through-feed design and a 600 Vac rating, reducing install time and commissioning risk. For engineers and maintenance teams, this configuration delivers predictable performance, easy field maintenance, and long-term cost savings through fewer spare parts and faster replacement cycles.
Product Information
Extended Description
EDSC2184 OP Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS pushbutton control station, With pushbuttons, Open, Feraloy iron alloy, Single circuit universal, 1, Single-gang, 1, Through feed, 3/4", 600 Vac
Product Name
Eaton Crouse-Hinds series EDS pushbutton control station
Catalog Number
EDSC2184 OP
Product Length/Depth
3.5 in
Product Height
6.72 in
Product Width
5.81 in
Product Weight
8.8 lb
UPC
782274048772
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class II, Division 1 Class III Class I, Division 1 Class I, Division 2 Class II, Division 2
NEMA Rating
7 3 9
Enclosure type
With pushbuttons
Voltage rating
600 Vac
Number of gangs
Single-gang
Number of pushbuttons
1
Number of devices
1
Normal position
Single circuit universal
Indicating plate markings
Open
Style
Through feed
Trade size
3/4"
Material
Feraloy iron alloy
SP3D Design Package - EDS and EFS Explosionproof Control Stations
EDS/EDSX Hazardous Area Control Stations catalog page
EDS and EFS Explosionproof Pushbutton, Pilot Light, and Selector Switch Control Stations UL certification
EDS and EFS Explosionproof Pushbutton, Pilot Light, and Selector Switch Control Stations UL certification
IF 328 - EDS, EFS, EDSC and EFSC Single- and Two-gang Device Bodies
IF 328 - EDS, EFS, EDSC and EFSC Single- and Two-gang Device Bodies
IF 328 - EDS, EFS, EDSC and EFSC Single- and Two-gang Device Bodies
Eaton Specification Sheet - EDSC2184 OP
Feature: Feraloy iron alloy enclosure provides robust arc and impact resistance in harsh environments. Business Impact: This increases equipment uptime and reduces replacement costs in oil, gas, and chemical processing. Application: Ideal for hazardous-location control stations in refinery pump skids and mining sites. Feature: 600 Vac rating and through-feed, single-gang design. Business Impact: Simplifies wiring, reduces panel space, and improves commissioning speed. Application: Suitable for compact machine control panels in industrial facilities. Feature: One pushbutton, one device, and open-indicating plate. Business Impact: Clear operator status and safer startup/shutdown sequences, minimizing misoperation. Application: Start/stop control in hazardous locations across manufacturing lines. Feature: Material: Feraloy iron alloy. Business Impact: Delivers superior corrosion and heat resistance for long service life in harsh environments. Application: Outdoor and chemical processing plants with exposure to contaminants. Feature: Compliance: NEC/CEC, with NEMA ratings 7, 3, 9. Business Impact: Regulatory peace of mind and UL certification simplify audits and installation. Application: Certified for Hazardous/Classified Locations, enabling reliable deployment in Division 1/2 and other high-risk zones. Feature: Through-feed, single-gang, 3/4 inch trade size. Business Impact: Flexible mounting and streamlined wiring in existing panels. Application: Retrofit or new installs in control cabinets for scalable automation.
Get a Quick Quote for a Eaton Crouse-Hinds EDSC2184 OP
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds EDSC2184 OP?
Enquire Now
FAQs
The EDSC2184 OP is designed for single-gang mounting with through-feed wiring and a 3/4" trade size. Install in accordance with IF328/IF899/IF372 instructions, ensuring the area classification (Hazardous/Classified Locations) and NEC/CEC compliance are observed. The enclosure’s feraloy alloy and 600 Vac rating support reliable operation in Division 1/2 and I/II environments, reducing wiring errors and downtime.
Catalog number EDSC2184 OP; one pushbutton; one device; single-gang; 600 Vac; through-feed; 3/4" trade size; feraloy iron alloy; dimensions roughly 3.5 in (L) × 5.81 in (W) × 6.72 in (H); weight 8.8 lb; indicating plate marking Open; NEMA ratings 7, 3, 9; NEC/CEC standards; UPC 782274048772.
Yes. It supports Hazardous/Classified Locations with NEC hazardous ratings covering Class I, II, III and Division 1/2, along with NEMA 7/3/9 protection. The unit complies with NEC/CEC standards and UL listings, ensuring regulatory conformity and safe operation in explosive atmospheres.
Ideal for oil & gas, chemical processing, mining, and other heavy-industrial settings requiring explosion-proof control. Its single-gang, through-feed design and 600 Vac rating suit motor-start circuits and line-side controls, while the open-indicating plate provides clear operator feedback in demanding environments.
Supporting materials include SP3D design packages, EDS/EDSX catalog pages, UL certification reports, and installation sheets (IF 328 style). These resources help with accurate panel design, compliance verification, and streamlined field installation across hazardous-location projects.