Eaton EDSC2184 S111 EM - Hazardous Location Pushbutton

Part Number: EDSC2184 S111 EM
Eaton Crouse-Hinds logo
Manufacturer
Eaton Crouse-Hinds
Part number
EDSC2184 S111 EM

Quick Summary

EDSC2184 S111 EM is a hazardous-location pushbutton control station designed for demanding industrial environments. Engineers frequently struggle with unreliable emergency-stop performance in dusty, moisture-laden or corrosive atmospheres. This unit meets NEC/CEC requirements and supports Class I, Division 1 and 2, Class II, Division 1 and 2, and Class III locations, with a NEMA rating of 9 3 7. With a through-feed, 3/4 in trade size enclosure and a front-operated emergency STOP button, it reduces wiring complexity and speeds installation. The combination delivers safer operation, faster commissioning, and lower lifecycle costs for hazardous-area automation projects.

Product Information

Extended Description

EDSC2184 S111 EM Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS pushbutton control station, With pushbuttons, Emergency, Feraloy iron alloy, Single circuit universal, 1, Single-gang, 1, Emergency "STOP" front-operated red mushrooon button, Through feed, 3/4", 600 Vac
Product Name
Eaton Crouse-Hinds series EDS pushbutton control station
Catalog Number
EDSC2184 S111 EM
Product Length/Depth
3.5 in
Product Height
6.72 in
Product Width
5.81 in
Product Weight
8.97 lb
UPC
782274122786
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2 Class II, Division 1 Class III Class II, Division 2
NEMA Rating
9 3 7
Enclosure type
With pushbuttons
Voltage rating
600 Vac
Number of gangs
Single-gang
Number of pushbuttons
1
Number of devices
1
Normal position
Single circuit universal
Indicating plate markings
Emergency
Style
Through feed
Trade size
3/4"
Material
Feraloy iron alloy
Special features
Emergency "STOP" front-operated red mushrooon button
Single-gang through-feed design concentrates control at the operator interface while reducing panel depth and wiring complexity, enabling compact, faster installations in automated lines. The unit houses a single pushbutton and a clearly marked emergency function, which minimizes misoperation and speeds up commissioning. The 3/4 in trade size enclosure and 600 Vac rating support dependable performance in demanding power circuits, while through-feed wiring streamlines acceptance testing and reduces panel modification time during upgrades. Feraloy iron alloy enclosure provides rugged durability against impact, temperature swings, and corrosive atmospheres common in oil, gas, chemical, and mining environments, translating into longer service life and lower maintenance costs. The emergency STOP button is front-operated and red mushroom styled, offering tactile feedback and reliable actuation, improving operator safety and reducing reaction time in emergencies. NEC/CEC compliance, Class I/II/III location ratings, and a NEMA 9/3/7 rating ensure regulatory alignment and easier system integration with EDS and EFS explosion-proof control stations.

Get a Quick Quote for a Eaton Crouse-Hinds EDSC2184 S111 EM

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds EDSC2184 S111 EM? Enquire Now

FAQs

Yes. The EDSC2184 S111 EM is designed for through-feed installation in single-gang enclosures, enabling straightforward wiring and streamlined panel integration. Its 3/4 inch trade size and front-operated emergency STOP facilitate fast, compliant mounting in harsh environments typical of hazardous locations, reducing field modifications and downtime during commissioning.
Key specifications include a 600 Vac voltage rating, one pushbutton, and a single-gang through-feed enclosure. The front-operated emergency STOP button provides reliable actuation, while the Feraloy iron alloy construction delivers durability in challenging environments. The unit is engineered for NEC/CEC compliance and supports hazardous area classifications including Class I, II, and III locations.
Industries such as oil and gas, chemical processing, mining, and other hazardous environments benefit from this station. Its hazardous-location ratings, rugged enclosure, and emergency-stop functionality make it ideal for machine start/stop panels, control stations in gritty or corrosive atmospheres, and critical safety applications where reliable operation is essential.
The EDSC2184 S111 EM supports NEC/CEC compliance and Hazardous/Classified Locations ratings with Class I, Division 1 and 2; Class II, Division 1 and 2; Class III. It carries a NEMA rating of 9, 3, 7 and is suitable for installations requiring certified explosionproof/hazardous-area control stations in through-feed configurations.
The single-gang, through-feed design simplifies wiring and reduces panel footprint, which lowers installation labor and spare parts needs. Front-operated emergency STOP provides immediate, intuitive de-energization, increasing operator safety and reducing downtime during fault conditions. Durable Feraloy construction minimizes replacement cycles in harsh sites, delivering favorable total cost of ownership over the equipment lifecycle.