Eaton EDSC2184 S153 Pushbutton Control Station - Explosionproof
Part Number: EDSC2184 S153
Quick Summary
The Eaton Crouse-Hinds EDSC2184 S153 pushbutton control station is a rugged interface for hazardous-location motor control and process automation. Facilities often struggle with achieving safety and uptime in Division 1/2 environments where ordinary control stations fail to meet harsh exposure or lockout requirements. This unit delivers NEC/CEC compliance, hazard classifications for Class I Division 1 and Class II Division 2, plus NEMA 3, 7, and 9 protection, ensuring reliable operation in challenging settings. By combining through-feed wiring, a compact single-gang footprint, and a 600 Vac rating, it provides a safer, more efficient path to compliant, maintainable control systems while reducing lifecycle costs and installation time.
Product Information
Extended Description
EDSC2184 S153 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS pushbutton control station, With pushbuttons, Feraloy iron alloy, Single circuit universal, 1, Single-gang, 1, Lockout provision, Through feed, 3/4", 600 Vac
Product Name
Eaton Crouse-Hinds series EDS pushbutton control station
Catalog Number
EDSC2184 S153
Product Length/Depth
3.5 in
Product Height
6.72 in
Product Width
5.81 in
Product Weight
8.89 lb
UPC
782274522975
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class II, Division 2 Class I, Division 2 Class II, Division 1 Class III
NEMA Rating
3 9 7
Enclosure type
With pushbuttons
Voltage rating
600 Vac
Number of gangs
Single-gang
Number of pushbuttons
1
Number of devices
1
Normal position
Single circuit universal
Style
Through feed
Trade size
3/4"
Material
Feraloy iron alloy
Special features
Lockout provision
SP3D Design Package - EDS and EFS Explosionproof Control Stations
EDS/EDSX Hazardous Area Control Stations catalog page
EDS and EFS Explosionproof Pushbutton, Pilot Light, and Selector Switch Control Stations UL certification
EDS and EFS Explosionproof Pushbutton, Pilot Light, and Selector Switch Control Stations UL certification
IF 372 - EDS Notice
IF 372 - EDS Notice
IF 372 - EDS Notice
Eaton Specification Sheet - EDSC2184 S153
Feature: One pushbutton, single-gang enclosure, 3/4" trade size and through-feed design → Business Impact: Simplifies installation and wiring topology, enabling faster panel assembly and reduced labor costs on new builds and upgrades → Application: Hazardous-location control stations in chemical plants or refineries where quick, safe manual control is required. Feature: Feraloy iron alloy enclosure → Business Impact: Superior mechanical strength and corrosion resistance extend service life in demanding environments → Application: Outdoor or harsh indoor areas with exposure to moisture, dust, and chemicals. Feature: Lockout provision → Business Impact: Supports compliant lockout-tagout procedures, lowering safety risk and downtime during maintenance → Application: Routine maintenance in maintenance-critical processes or safety-critical circuits. Feature: NEC/CEC compliance with hazardous-area ratings (Class I, Division 1; Class II, Division 2; Class I, Division 2; Class II, Division 1; Class III) and NEMA 3, 7, 9 → Business Impact: Reduces regulatory risk and qualification time for industrial projects → Application: Electrical installations in hazardous locations requiring robust regulatory alignment. Feature: Through-feed, single-circuit universal operation → Business Impact: Minimizes wiring complexity and improves downstream integration with existing control schemes → Application: Retrofit projects where space is constrained but reliability is non-negotiable. Feature: 600 Vac voltage rating → Business Impact: Broad compatibility with common industrial power standards, enabling seamless integration with motor starters and drives → Application: High-power control stations in industrial automation lines.
Get a Quick Quote for a Eaton Crouse-Hinds EDSC2184 S153
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds EDSC2184 S153?
Enquire Now
FAQs
Mount the single-gang EDSC2184 S153 in a through-feed enclosure designed for hazardous locations. Use 3/4" conduit entries and follow the lockout provision for maintenance. The unit’s 600 Vac rating and fault-resilient wiring help ensure safety, while its compact footprint reduces panel space needs during retrofits or new installations.
Key ratings include 600 Vac operation, single pushbutton, one device, and single-gang enclosure. Certifications encompass NEC/CEC compliance with Class I, Division 1; Class II, Division 2; Class I, Division 2; Class II, Division 1; Class III, plus NEMA 3, 7, 9 protection, making it suitable for hazardous and industrial environments.
Yes. The EDSC2184 S153 features through-feed wiring, a compact single-gang form factor, and a universal normal position, which simplifies replacement in existing circuits while maintaining compliance with hazardous-location classifications and safety standards.
Verify NEC/CEC compliance, hazardous-location certifications for Class I and Class II divisions, UL certification for explosionproof applications, and the NEMA ratings 3, 7, 9 to ensure suitability for outdoor or intensive indoor use in your facility.
The rugged Feraloy iron alloy enclosure reduces corrosion wear, and the lockout feature minimizes maintenance-related incidents. Combined with reduced wiring complexity and faster installation, maintenance costs decline, downtime is minimized, and overall return on investment improves in high-risk industrial settings.