Eaton EDSC2184 S153 Pushbutton Control Station - Explosionproof

Part Number: EDSC2184 S153
Eaton Crouse-Hinds logo
Manufacturer
Eaton Crouse-Hinds
Part number
EDSC2184 S153

Quick Summary

The Eaton Crouse-Hinds EDSC2184 S153 pushbutton control station is a rugged interface for hazardous-location motor control and process automation. Facilities often struggle with achieving safety and uptime in Division 1/2 environments where ordinary control stations fail to meet harsh exposure or lockout requirements. This unit delivers NEC/CEC compliance, hazard classifications for Class I Division 1 and Class II Division 2, plus NEMA 3, 7, and 9 protection, ensuring reliable operation in challenging settings. By combining through-feed wiring, a compact single-gang footprint, and a 600 Vac rating, it provides a safer, more efficient path to compliant, maintainable control systems while reducing lifecycle costs and installation time.

Product Information

Extended Description

EDSC2184 S153 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS pushbutton control station, With pushbuttons, Feraloy iron alloy, Single circuit universal, 1, Single-gang, 1, Lockout provision, Through feed, 3/4", 600 Vac
Product Name
Eaton Crouse-Hinds series EDS pushbutton control station
Catalog Number
EDSC2184 S153
Product Length/Depth
3.5 in
Product Height
6.72 in
Product Width
5.81 in
Product Weight
8.89 lb
UPC
782274522975
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class II, Division 2 Class I, Division 2 Class II, Division 1 Class III
NEMA Rating
3 9 7
Enclosure type
With pushbuttons
Voltage rating
600 Vac
Number of gangs
Single-gang
Number of pushbuttons
1
Number of devices
1
Normal position
Single circuit universal
Style
Through feed
Trade size
3/4"
Material
Feraloy iron alloy
Special features
Lockout provision
Feature: One pushbutton, single-gang enclosure, 3/4" trade size and through-feed design → Business Impact: Simplifies installation and wiring topology, enabling faster panel assembly and reduced labor costs on new builds and upgrades → Application: Hazardous-location control stations in chemical plants or refineries where quick, safe manual control is required. Feature: Feraloy iron alloy enclosure → Business Impact: Superior mechanical strength and corrosion resistance extend service life in demanding environments → Application: Outdoor or harsh indoor areas with exposure to moisture, dust, and chemicals. Feature: Lockout provision → Business Impact: Supports compliant lockout-tagout procedures, lowering safety risk and downtime during maintenance → Application: Routine maintenance in maintenance-critical processes or safety-critical circuits. Feature: NEC/CEC compliance with hazardous-area ratings (Class I, Division 1; Class II, Division 2; Class I, Division 2; Class II, Division 1; Class III) and NEMA 3, 7, 9 → Business Impact: Reduces regulatory risk and qualification time for industrial projects → Application: Electrical installations in hazardous locations requiring robust regulatory alignment. Feature: Through-feed, single-circuit universal operation → Business Impact: Minimizes wiring complexity and improves downstream integration with existing control schemes → Application: Retrofit projects where space is constrained but reliability is non-negotiable. Feature: 600 Vac voltage rating → Business Impact: Broad compatibility with common industrial power standards, enabling seamless integration with motor starters and drives → Application: High-power control stations in industrial automation lines.

Get a Quick Quote for a Eaton Crouse-Hinds EDSC2184 S153

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds EDSC2184 S153? Enquire Now

FAQs

Mount the single-gang EDSC2184 S153 in a through-feed enclosure designed for hazardous locations. Use 3/4" conduit entries and follow the lockout provision for maintenance. The unit’s 600 Vac rating and fault-resilient wiring help ensure safety, while its compact footprint reduces panel space needs during retrofits or new installations.
Key ratings include 600 Vac operation, single pushbutton, one device, and single-gang enclosure. Certifications encompass NEC/CEC compliance with Class I, Division 1; Class II, Division 2; Class I, Division 2; Class II, Division 1; Class III, plus NEMA 3, 7, 9 protection, making it suitable for hazardous and industrial environments.
Yes. The EDSC2184 S153 features through-feed wiring, a compact single-gang form factor, and a universal normal position, which simplifies replacement in existing circuits while maintaining compliance with hazardous-location classifications and safety standards.
Verify NEC/CEC compliance, hazardous-location certifications for Class I and Class II divisions, UL certification for explosionproof applications, and the NEMA ratings 3, 7, 9 to ensure suitability for outdoor or intensive indoor use in your facility.
The rugged Feraloy iron alloy enclosure reduces corrosion wear, and the lockout feature minimizes maintenance-related incidents. Combined with reduced wiring complexity and faster installation, maintenance costs decline, downtime is minimized, and overall return on investment improves in high-risk industrial settings.