Eaton Crouse-Hinds EDSC2184 SP Pushbutton Control Station - Hazardous/Classified Locations
Part Number: EDSC2184 SP
Quick Summary
The Eaton Crouse-Hinds EDSC2184 SP pushbutton control station provides reliable start/stop control for hazardous-location equipment. This solution addresses the common challenge of safely operating in explosive environments where miswiring or under-protected enclosures can cause costly downtime. Designed for through-feed, single-gang installations, it uses a feraloy iron alloy enclosure and a 600 Vac rating to handle demanding power profiles. It carries NEC/CEC compliance and UL hazardous-location certifications, with NEMA ratings 7, 9, and 3 to withstand dust, water exposure, and impact. By delivering rugged protection with straightforward integration, it supports safer operations and lowers lifecycle costs across plant control schemes, while aligning with industry-standard installation practices.
Product Information
Extended Description
EDSC2184 SP Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS pushbutton control station, With pushbuttons, Stop, Feraloy iron alloy, Single circuit universal, 1, Single-gang, 1, Through feed, 3/4", 600 Vac
Product Name
Eaton Crouse-Hinds series EDS pushbutton control station
Catalog Number
EDSC2184 SP
Product Length/Depth
3.5 in
Product Height
6.72 in
Product Width
5.81 in
Product Weight
8.22 lb
UPC
782274681627
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class II, Division 1 Class I, Division 1 Class III Class II, Division 2 Class I, Division 2
NEMA Rating
7 9 3
Enclosure type
With pushbuttons
Voltage rating
600 Vac
Number of gangs
Single-gang
Number of pushbuttons
1
Number of devices
1
Normal position
Single circuit universal
Indicating plate markings
Stop
Style
Through feed
Trade size
3/4"
Material
Feraloy iron alloy
SP3D Design Package - EDS and EFS Explosionproof Control Stations
EDS/EDSX Hazardous Area Control Stations catalog page
EDS and EFS Explosionproof Pushbutton, Pilot Light, and Selector Switch Control Stations UL certification
EDS and EFS Explosionproof Pushbutton, Pilot Light, and Selector Switch Control Stations UL certification
IF 328 - EDS, EFS, EDSC and EFSC Single- and Two-gang Device Bodies
IF 328 - EDS, EFS, EDSC and EFSC Single- and Two-gang Device Bodies
IF 328 - EDS, EFS, EDSC and EFSC Single- and Two-gang Device Bodies
Eaton Specification Sheet - EDSC2184 SP
Hazardous-location certified enclosure for compliance and safety → Reduces regulatory risk and downtime in chemical, oil & gas, and mining environments; ideal for control stations in hazardous locations. Through-feed, single-gang design with 3/4" trade size → Simplifies wiring and panel layout, accelerating commissioning and reducing field errors in harsh installations. 600 Vac rating with feraloy iron alloy construction → Supports high-power applications while maintaining enclosure integrity, lowering replacement costs and improving reliability. NEC/CEC standards and UL hazardous-location certifications with NEMA 7/9/3 → Ensures regulatory alignment and safer operation under dust, water, and impact conditions; minimizes cross-compatibility issues across facilities. Indicating plate marked Stop and one pushbutton/one device configuration → Streamlines operator interactions and standardizes control behavior, boosting process safety and training efficiency. Comprehensive documentation and installation compatibility → Reduces risk during upgrades or retrofits, with reference materials like IF 328 and catalog pages supporting fast, error-free deployments.
Get a Quick Quote for a Eaton Crouse-Hinds EDSC2184 SP
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds EDSC2184 SP?
Enquire Now
FAQs
For safe, compliant installation, plan a through-feed, single-gang footprint using a 3/4" trade size. Ensure mounting aligns with device bodies designed for hazardous areas, and reference IF 328 installation sheets and catalog pages to verify wiring methods, terminal locations, and gasket integrity for Class I/II/III environments.
Yes. It is rated for 600 Vac with a single pushbutton controlling one device. The unit is designed for through-feed operation in a single-gang enclosure, featuring a Stop-indicating plate. This configuration supports standard stop/start control in hazardous locations while minimizing panel footprint.
The device complies with NEC/CEC standards and carries UL explosion-proof certifications for hazardous locations, including Class I/II/III and Division 1 and 2. It also aligns with NEMA ratings 7, 9, and 3, ensuring performance in demanding industrial environments.
The unit fits a single-gang opening with dimensions approximately 6.72 in high, 5.81 in wide, and 3.5 in deep, with a weight of about 8.22 lb. These metrics help ensure proper clearance, mounting, and access within control panels and enclosures.
It enhances safety and compliance in hazardous environments by meeting NEC/CEC and UL requirements, reducing risk of outages and penalties. The through-feed, compact single-gang design enables faster install, easier maintenance, and lower lifecycle costs, while providing reliable operation for critical start/stop control.