Eaton Crouse-Hinds EDSC2190 GB EDS Pushbutton - Hazardous
Part Number: EDSC2190 GB
Quick Summary
EDS pushbutton control station provides rugged, local control for machines in hazardous locations. Engineers often struggle with safety, inspection cycles, and compliance when installing control stations in Class I Division 1 environments. This unit offers NEC/CEC compliance along with robust hazardous-area ratings (Class I, Division 1 and 2) and a NEMA enclosure for tough outdoor or dirty environments. The through-feed, single-gang design with a 3/4 in trade size simplifies wiring, minimizes panel footprint, and eases retrofit projects. By combining reliable operation with straightforward installation, it supports safer, faster commissioning and lower lifecycle costs in industrial automation environments.
Product Information
Extended Description
EDSC2190 GB Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS pushbutton control station, With pushbuttons, Feraloy iron alloy, Two circuit universal, 2, Single-gang, 2, Suitable for Class I, Division 1, Group B, Through feed, 3/4"
Product Name
Eaton Crouse-Hinds series EDS pushbutton control station
Catalog Number
EDSC2190 GB
Product Length/Depth
3.5 in
Product Height
6.72 in
Product Width
5.81 in
Product Weight
9.08 lb
UPC
782274896373
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 2 Class II, Division 2 Class I, Division 1 Class II, Division 1 Class III
NEMA Rating
3 9 7
Enclosure type
With pushbuttons
Number of gangs
Single-gang
Number of pushbuttons
2
Number of devices
2
Normal position
Two circuit universal
Style
Through feed
Trade size
3/4"
Material
Feraloy iron alloy
Special features
Suitable for Class I, Division 1, Group B
SP3D Design Package - EDS and EFS Explosionproof Control Stations
EDS/EDSX Hazardous Area Control Stations catalog page
EDS and EFS Explosionproof Pushbutton, Pilot Light, and Selector Switch Control Stations UL certification
EDS and EFS Explosionproof Pushbutton, Pilot Light, and Selector Switch Control Stations UL certification
IF 328 - EDS, EFS, EDSC and EFSC Single- and Two-gang Device Bodies
IF 328 - EDS, EFS, EDSC and EFSC Single- and Two-gang Device Bodies
IF 328 - EDS, EFS, EDSC and EFSC Single- and Two-gang Device Bodies
Eaton Specification Sheet - EDSC2190 GB
Feature: Feraloy iron alloy enclosure provides rugged, explosionproof protection. Benefit: Enhances operator safety and enclosure integrity in harsh environments, reducing downtime from corrosion or impact. Application: Hazardous locations where mechanical resilience and containment are critical. Feature: Two pushbuttons and two devices in a single-gang body. Benefit: Streamlines control circuits, lowers panel depth, and minimizes wiring complexity. Application: Through-feed control stations on conveyors, pumps, and presses in hazardous areas. Feature: Through-feed, 3/4" trade size design. Benefit: Eases field wiring and retrofit upgrades, enabling faster installation and scalable expansion. Application: Modular control stations in oil & gas, chemical, and mining facilities. Feature: NEC/CEC compliance with Class I, Division 1/2 and Class II/III ratings; NEMA 3, 9, 7. Benefit: Regulatory assurance, safer operation, and suitability for indoor/outdoor hazardous environments. Application: Industrial plants requiring certified equipment for hazardous locations. Feature: Compatibility with EDS/EDSX control-station ecosystem and installation resources. Benefit: Simplifies procurement, standardizes maintenance, and supports proven field practices. Application: New builds and retrofits in process industries needing reliable control interfaces.
Get a Quick Quote for a Eaton Crouse-Hinds EDSC2190 GB
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds EDSC2190 GB?
Enquire Now
FAQs
EDSC2190 GB is designed for single-gang mounting and 3/4 in trade size through-feed installations, compatible with Crouse-Hinds EDS/EDSX control-station ecosystems. Refer to IF 328 instruction sheets for single- and two-gang device bodies to ensure proper fit, wiring method, and safety clearances during retrofit or new installations.
The unit is NEC/CEC compliant and rated for Hazardous/Classified Locations, including Class I Division 1 and 2, Class II Division 1 and 2, and Class III. It also carries a NEMA rating of 3, 9, 7, supporting protection against dust, water ingress, and nonincendive environments typical in industrial plants.
Best suited for through-feed control stations in hazardous environments such as oil and gas, chemical processing, and mining. The two-pushbutton, two-device configuration within a single-gang enclosure supports compact, safe local control, reducing wiring complexity and enabling quicker commissioning on new builds or plant expansions.
Two pushbuttons allow dedicated start/stop or process-safety signaling within a compact unit, simplifying operator procedures and reducing misoperation. The rugged enclosure and hazardous-location ratings support long service life in tough environments, lowering maintenance frequency and enabling safer, compliant operation with minimal panel space.
Documentation is available through Eaton’s resources, including SP3D Design Packages for EDS/EDSX, catalog pages, UL certification reports, IF instruction sheets for device bodies, and the Eaton specification sheet for EDSC2190 GB. These assets support proper installation, commissioning, and ongoing maintenance in hazardous-location applications.