Eaton EDSC2190 S153 Pushbutton Control Station provides safe control interlock for hazardous-area applications in oil, gas, and chemical facilities. Operators often struggle with complex lockout procedures and strict compliance in explosive environments. This unit meets NEC/CEC standards and hazardous area classifications, with NEMA ratings 7, 3, and 9 to endure harsh conditions. Coupled with through-feed wiring and a two-pushbutton, two-device configuration, it delivers a reliable, install-ready solution that reduces downtime and supports scalable control schemes across evolving safety requirements. Its feraloy iron alloy enclosure and 3/4" trade size simplify installation in compact control panels while offering long service life and easier maintenance.
Product Information
Extended Description
EDSC2190 S153 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS pushbutton control station, With pushbuttons, Feraloy iron alloy, Two circuit universal, 2, Single-gang, 2, Lockout provision, Through feed, 3/4", 600 Vac
Product Name
Eaton Crouse-Hinds series EDS pushbutton control station
Catalog Number
EDSC2190 S153
Product Length/Depth
3.5 in
Product Height
6.72 in
Product Width
5.81 in
Product Weight
9.02 lb
UPC
782274523170
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2 Class II, Division 1 Class II, Division 2 Class III
NEMA Rating
7 3 9
Enclosure type
With pushbuttons
Voltage rating
600 Vac
Number of gangs
Single-gang
Number of pushbuttons
2
Number of devices
2
Normal position
Two circuit universal
Style
Through feed
Trade size
3/4"
Material
Feraloy iron alloy
Special features
Lockout provision
SP3D Design Package - EDS and EFS Explosionproof Control Stations
EDS/EDSX Hazardous Area Control Stations catalog page
EDS and EFS Explosionproof Pushbutton, Pilot Light, and Selector Switch Control Stations UL certification
EDS and EFS Explosionproof Pushbutton, Pilot Light, and Selector Switch Control Stations UL certification
IF 372 - EDS Notice
IF 372 - EDS Notice
IF 372 - EDS Notice
Eaton Specification Sheet - EDSC2190 S153
Two pushbuttons with two devices fit a single-gang enclosure, delivering a compact control point for hazardous-area applications. This footprint reduces panel space and simplifies routing, speeding installation while preserving separate start/stop or signaling functions. Suitable for petrochemical, mining, and other facilities where space is at a premium and reliability matters. Through-feed wiring combined with a lockout provision enhances maintenance safety. The feature minimizes accidental resets during service and supports compliant lockout/tagout practices, reducing risk and downtime. It’s a practical choice for offshore rigs, refineries, and chemical plants where access is limited and safety procedures must be airtight. Rated at 600 Vac, this station handles motor and automation circuits commonly found in industrial environments. The two-button, two-device arrangement supports versatile control schemes, improving operator efficiency and enabling straightforward hand-off between devices. It’s well suited for conveyors, pumps, and fans in harsh locations. Constructed from Feraloy iron alloy, the enclosure delivers rugged impact and corrosion resistance. The robust material, combined with hazardous-location ratings, reduces maintenance costs and extends service life in challenging atmospheres. This makes it an economical choice for long-term ROI in chemical plants and oil/gas facilities. Compliance is built in: NEC/CEC standards and hazardous-location certifications, plus NEMA ratings 7, 3, and 9, provide regulatory assurance and inspector-friendly documentation. With this foundation, projects meet design requirements and pass audits more smoothly, while installation remains straightforward for qualified technicians. Designed for compatibility with the Eaton Crouse-Hinds EDS family, the EDSC2190 S153 supports through-feed wiring, lockout, and 3/4 in trade size. Installation is simplified by a known form factor and standardized mounting, making retrofits and upgrades faster and less risky.
Get a Quick Quote for a Eaton Crouse-Hinds EDSC2190 S153
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds EDSC2190 S153?
Enquire Now
FAQs
Yes. The EDSC2190 S153 supports through-feed wiring and includes a lockout provision, enabling safe maintenance and compliant lockout/tagout procedures in Class I, II, and III hazardous locations. Its 600 Vac rating and single-gang, two-device configuration make it straightforward to retrofit into existing panels without sacrificing safety or reliability.
This model features a 600 Vac voltage rating with two pushbuttons and two devices installed. It follows a two-circuit universal normal position and a through-feed enclosure design, allowing flexible control schemes while maintaining compact panel footprint suitable for hazardous-area installations.
The EDSC2190 S153 is listed for Hazardous/Classified Locations under NEC/CEC standards, with Class I Division 1 and 2, Class II Division 1 and 2, and Class III ratings. It also carries NEMA ratings 7, 3, and 9, making it appropriate for oil and gas, chemical processing, mining, and other harsh industrial settings.
The built-in lockout provision prevents unexpected re-energization during servicing, supporting documented lockout/tagout practices. This reduces the risk of injury, minimizes downtime, and speeds regulatory inspections, which is especially valuable in hazardous environments where simultaneous mechanical and electrical work occurs.
Plan for a single-gang enclosure with 3/4" trade size and a two-device, two-pushbutton configuration. Ensure compatibility with through-feed wiring, proper enclosure sealing for hazardous locations, and compliance with NEC/CEC requirements. Refer to installation sheets IF 372 and the catalog for mounting dimensions and mounting hardware recommendations.