Eaton EDSC2190 S769 Pushbutton Station - Hazardous Locations

Part Number: EDSC2190 S769
Eaton Crouse-Hinds logo
Manufacturer
Eaton Crouse-Hinds
Part number
EDSC2190 S769

Quick Summary

EDSC2190 S769 pushbutton control station provides robust, two-button control for hazardous-location machinery. Operators in industrial plants frequently confront safety, reliability, and downtime challenges in harsh environments; this unit's maintained-contact mushroom head with lockout and guard prevents unintended starts and supports safe maintenance. Built to NEC/CEC hazardous-area standards, it also carries a NEC hazardous rating and area-classification designation along with a rugged NEMA 7/3/9 enclosure, making it suitable for Class I, II, and III locations. By combining a compact single-gang footprint with through-feed wiring, the EDSC2190 S769 delivers simplified installation and reduced panel space. This translates to lower installation costs and improved long-term maintenance for safety-critical control applications in oil, gas, mining, and chemical processing.

Product Information

Extended Description

EDSC2190 S769 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS pushbutton control station, With pushbuttons, Feraloy iron alloy, Two circuit universal, 2, Single-gang, 2, Maintained contact mushroom head with lockout and guard, Through feed, 3/4", 600 Vac
Product Name
Eaton Crouse-Hinds series EDS pushbutton control station
Catalog Number
EDSC2190 S769
Product Length/Depth
3.5 in
Product Height
6.72 in
Product Width
5.81 in
Product Weight
8.4 lb
UPC
662276112063
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 2 Class III Class II, Division 2 Class I, Division 1 Class II, Division 1
NEMA Rating
7 3 9
Enclosure type
With pushbuttons
Voltage rating
600 Vac
Number of gangs
Single-gang
Number of pushbuttons
2
Number of devices
2
Normal position
Two circuit universal
Style
Through feed
Trade size
3/4"
Material
Feraloy iron alloy
Special features
Maintained contact mushroom head with lockout and guard
Feature: Two pushbuttons in a single-gang enclosure with a maintained-contact mushroom head and lockout/guard. Benefit: Delivers reliable, lockable control to prevent accidental restarts, reducing risk during servicing in hazardous locations. Application: Start/stop sequences in control stations for hazardous-area equipment across oil, gas, and chemical processing sites. Feature: 600 VAC rating and 3/4" trade size with through-feed wiring. Benefit: Compatible with common plant power systems and streamlined wiring, shortening installation time and minimizing wiring errors. Application: Standardized integration into panelboards and control circuits in industrial facilities. Feature: Feraloy iron alloy enclosure. Benefit: Enhanced durability and corrosion resistance in tough environments, lowering maintenance costs and extending product life. Application: Chemical plants, mining operations, and other harsh-duty settings. Feature: Through-feed, single-gang design with two devices. Benefit: Space-efficient installation with flexible device configurations, reducing panel footprint and capital expense. Application: Control stations where compact form factor and dual-device capability are required. Feature: NEC/CEC compliance and NEMA ratings (7, 3, 9). Benefit: Regulatory confidence and predictable performance in hazardous and outdoor atmospheres, aiding compliance and safety audits. Application: Hazardous/classified locations, marine and outdoor control installations. Feature: Normal position is two-circuit universal. Benefit: Greater wiring flexibility and device compatibility, supporting future expansions without rework. Application: Industrial automation schemes requiring scalable pushbutton control.

Get a Quick Quote for a Eaton Crouse-Hinds EDSC2190 S769

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds EDSC2190 S769? Enquire Now

FAQs

What wiring and mounting options does the EDSC2190 S769 support? It is a single-gang enclosure with a 3/4" trade size and through-feed wiring, designed for two pushbuttons and two devices. Follow NEC/CEC guidelines for Class I, II, III installations, and ensure proper enclosure sealing and locking guard usage during maintenance to maintain safety and compliance.
Yes. The unit is designed for hazardous locations with NEC/CEC compliance, area-classification specifications, and NEMA ratings 7, 3, and 9, enabling safe operation in Class I Division 1 and related hazardous zones when installed per manufacturer instructions.
Key specs include 600 Vac voltage rating, two pushbuttons, two devices, single-gang enclosure with through-feed, 3/4" trade size, Feraloy iron alloy construction, and a maintained-contact mushroom head with lockout and guard. It is rated for hazardous locations under NEC/CEC standards and has NEMA 7, 3, 9 protection.
The EDSC2190 S769 carries NEC/CEC standards compliance, hazardous-area area classifications, Class I/II/III ratings, and NEMA ratings 7, 3, and 9. These certifications support safe operation in hazardous and classified locations and ease regulatory inspections.
It improves safety with lockout-capable maintenance, reduces downtime through reliable, maintained contacts, and lowers installation and maintenance costs via a compact, through-fed, two-device design that fits standard 600 Vac control architectures.