Eaton EDSC3130 Snap Switch - Hazardous/Classified Locations

Part Number: EDSC3130
Manufacturer
Eaton Crouse-Hinds
Part number
EDSC3130

Quick Summary

The Eaton EDSC3130 Snap Switch control station delivers rugged 20A switching for hazardous location motor controls in industrial facilities. Operators contend with downtime and complex wiring in corrosive or explosive environments; this enclosure consolidates control and simplifies maintenance by providing a single, certified unit that supports quick diagnostics. It carries NEC/CEC compliance with Class I Division 1 and 2, Class II Division 1 and 2, and Class III ratings, plus NEMA 3, 7, 9 enclosure protection for proven safety and durability. Designed for through-feed wiring and compact footprint, it supports 120–277V systems and two pushbuttons, delivering installation efficiency and a clear business value for reliability-driven projects.

Product Information

Extended Description

EDSC3130 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS snap switch control station, 20A, With switch, With two 1" hubs, Feraloy iron alloy, 1, Single-gang, Three-pole, 2, 120-277V, Through Feed, 3-way, 1", 120-277 Vac
Product Name
Eaton Crouse-Hinds series EDS snap switch control station
Catalog Number
EDSC3130
Product Length/Depth
5.06 in
Product Height
5.875 in
Product Width
3.5 in
Product Weight
8.6 lb
UPC
782274765891
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2 Class II, Division 1 Class II, Division 2 Class III
NEMA Rating
3 7 9
Enclosure type
With switch
Trade size
1"
Number Of Poles
Three-pole
Switch function
3-way
Number of gangs
Single-gang
Style
Through feed
Voltage rating
120-277 Vac
Amperage Rating
20A
Hub style
With two 1" hubs
Number of devices
1
Number of pushbuttons
2
Primary voltage range
120-277V
Material
Feraloy iron alloy
Feature: 20A, 120-277V, three-pole switch configuration. Business Impact: Enables reliable control of heavy loads in hazardous zones, reducing the need for multiple devices and cutting wiring complexity. Application: Motor control circuits on packaging lines or plant equipment where safety and reliability are critical. Feature: Through-feed single-gang enclosure with two 1-inch hubs. Business Impact: Speeds field wiring and simplifies future expansions, minimizing installation time and labor costs. Application: New installations and retrofit projects in hazardous locations requiring fast, compliant wiring access. Feature: Feraloy iron alloy enclosure. Business Impact: Delivers robust mechanical protection and corrosion resistance in harsh environments, lowering maintenance frequency. Application: Chemical processing and mining environments where enclosure integrity matters. Feature: NEC/CEC compliance and NEMA ratings (Class I, Division 1/2; Class II, Division 1/2; Class III; NEMA 3, 7, 9). Business Impact: Ensures regulatory alignment and permit readiness, reducing compliance risks and audit findings. Application: Industrial facilities with strict safety standards and certification requirements. Feature: Through-feed, 1-inch trade size and 2 pushbuttons. Business Impact: Streamlines control logic and operator interaction in a compact footprint, improving operator response times. Application: Standalone control stations on small to mid-size machines in hazardous areas.

Get a Quick Quote for a Eaton Crouse-Hinds EDSC3130

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds EDSC3130? Enquire Now

FAQs

Yes. The EDSC3130 is designed for Hazardous/Classified Locations and carries NEC/CEC compliance with ratings that cover Class I, Division 1 and 2, Class II Division 1 and 2, and Class III. This ensures regulatory alignment for installations in hazardous environments and simplifies permit and inspection processes.
The device is a 20A, 120–277V snap switch control station with a three-pole, single-gang enclosure. It includes two pushbuttons and supports through-feed wiring with two 1-inch hubs, making it suitable for robust control circuits in industrial applications.
With through-feed capability, two 1-inch hubs, and a single-gang footprint, installation is faster and less error-prone. The durable Feraloy iron alloy enclosure provides protection in harsh environments, reducing maintenance calls and extending service intervals in demanding facilities.
Yes. The EDSC3130 carries NEC/CEC standards with hazardous area ratings, along with NEMA ratings of 3, 7, and 9. This combination supports compliance in varied industrial settings such as chemical processing, mining, and energy sectors, while enabling safer operation.
By consolidating control within a certified snap switch station, facilities can reduce field wiring complexity, installation time, and maintenance visits. The robust enclosure and hazardous-location ratings help minimize downtime and non-compliance costs, delivering measurable lifecycle savings and improved process uptime.