Eaton Crouse-Hinds EDSC315 Pushbutton Station - 600V
Part Number: EDSC315
Quick Summary
EDSC315 pushbutton control station from Eaton Crouse-Hinds delivers rugged control for hazardous locations in industrial automation. In tough environments, downtime, miswiring, and noncompliant equipment can cripple production and safety. This device meets NEC/CEC requirements and hazardous-area ratings, including Class I, Division 1 and Division 2, Class II, Division 1 and 2, and Class III, together with NEMA ratings 3, 7, and 9. With two pushbuttons, two devices, a through-feed enclosure, and a 1" trade size, it combines compact footprint with clear Start/Stop signaling. The result is faster commissioning, safer operation, and easier maintenance, while supporting seamless integration with existing control systems and a wide range of industrial applications.
Product Information
Extended Description
EDSC315 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS pushbutton control station, With pushbuttons, Start, Stop, Feraloy iron alloy, Two circuit, 2, Single-gang, 2, Through feed, 1", 600 Vac
Product Name
Eaton Crouse-Hinds series EDS pushbutton control station
Catalog Number
EDSC315
Product Length/Depth
3.5 in
Product Height
5.91 in
Product Width
5.81 in
Product Weight
8.65 lb
UPC
782274765327
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2 Class II, Division 1 Class II, Division 2 Class III
NEMA Rating
3 7 9
Enclosure type
With pushbuttons
Voltage rating
600 Vac
Number of gangs
Single-gang
Number of pushbuttons
2
Number of devices
2
Normal position
Two circuit
Indicating plate markings
Start, Stop
Style
Through feed
Trade size
1"
Material
Feraloy iron alloy
SP3D Design Package - EDS and EFS Explosionproof Control Stations
EDS/EDSX Hazardous Area Control Stations catalog page
EDS and EFS Explosionproof Pushbutton, Pilot Light, and Selector Switch Control Stations UL certification
EDS and EFS Explosionproof Pushbutton, Pilot Light, and Selector Switch Control Stations UL certification
IF 372 - EDS Notice
IF 372 - EDS Notice
IF 372 - EDS Notice
Eaton Specification Sheet - EDSC315
Feraloy iron alloy construction provides exceptional heat resistance and impact strength, helping the EDSC315 endure harsh environments. This material choice translates to longer service life and lower maintenance costs in plants with high oil exposure, dust, and vibration. Operators in mining, chemical processing, and refineries benefit from dependable starts and stops even under demanding conditions. 600 Vac capacity paired with two internal circuits supports direct motor control and routine start/stop tasks without additional contactors or accessories. The through-feed design minimizes panel wiring and reduces installation time, which lowers commissioning costs. In practice, engineers see quicker field retrofits when upgrading legacy equipment in hazardous areas. Single-gang, through-feed enclosure with a 1 inch trade size delivers a compact footprint that fits standard electrical boxes and control panels. This simplifies alignment with existing devices and reduces panel rework during upgrades. Two pushbuttons provide distinct Start and Stop functions with clear visual indication for operators. Indicating plate markings read Start and Stop, ensuring intuitive operation and safer device sequencing in critical operations. The unit supports two devices in a compact 2-position configuration, enabling reliable control of dual-circuit systems. This combination helps prevent operator error and aligns with disciplined lockout/tagout practices. Certified for hazardous locations under NEC/CEC, with Class I, Division 1 and 2, Class II, Division 1 and 2, and Class III ratings, plus NEMA 3, 7, 9 protection. These approvals give procurement confidence for oil, gas, chemical, and mining environments, including outdoor installations. The rating suite also reduces the need for separate explosionproof enclosures and simplifies documentation. Designed to integrate with Eaton Crouse-Hinds EDS and EFS explosionproof control stations, the EDSC315 offers consistent termination, wiring schemes, and mounting patterns. Through-feed construction supports easy wiring and faster fault isolation. Compatibility with standard 1" knockout widths accelerates panel upgrades across existing installations. Long-term reliability is reinforced by straightforward maintenance routines and readily available spare parts, minimizing downtime during scheduled maintenance windows. The 600 Vac rating and robust enclosure mitigate nuisance trips and corrosion-related failures. Across industries, this translates into lower total cost of ownership and improved system uptime.
Get a Quick Quote for a Eaton Crouse-Hinds EDSC315
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds EDSC315?
Enquire Now
FAQs
Yes. The EDSC315 is designed to integrate with Eaton Crouse-Hinds EDS/EDSX explosionproof control stations and shares common mounting and wiring patterns. Its through-feed enclosure and 1" trade size simplify retrofits, reduce panel rework, and minimize field wiring errors during upgrades or expansions in hazardous locations.
Key specs include a 600 Vac voltage rating, two pushbuttons, two devices, and a single-gang enclosure with through-feed wiring. It supports Start/Stop control for dual-circuit configurations and is suitable for Class I, Division 1 and 2, Class II, Division 1 and 2, and Class III environments, with NEC/CEC compliance and NEMA protection.
Yes. The EDSC315 carries NEC hazardous-location ratings that include Class I, Division 1 and 2, along with Class II and Class III classifications. This makes it appropriate for high-risk areas such as oil and gas processing, chemical plants, and other hazardous locations requiring explosionproof operation and certified enclosures.
The EDSC315 aligns with NEC/CEC standards for hazardous locations and carries UL-related explosionproof considerations. Certifications cover area classifications and NEMA ratings (3, 7, 9), which streamline procurement, ensure regulatory compliance, and simplify documentation for safety audits and plant certifications.
Expect improved uptime due to rugged Feraloy iron alloy construction and a durable through-feed enclosure that withstands heat, impact, and exposure. The two-pushbutton, two-device design reduces wiring complexity and field fault sources, delivering lower maintenance costs, faster commissioning, and a lower total cost of ownership in harsh industrial environments.