Eaton EDSC3184 ST Pushbutton - Hazardous Locations
Part Number: EDSC3184 ST
Quick Summary
EDS pushbutton control stations like the Eaton EDSC3184 ST provide reliable local control in hazardous locations. Engineers often struggle with mounting a compact, compliant solution that fits tight panels while standing up to harsh environments. This device carries NEC/CEC compliance and multiple hazardous ratings, including Class I, Division 2; Class II, Division 1 and 2; Class III, complemented by a NEMA 3, 7, 9 enclosure. With a 1-gang footprint, 1 pushbutton, 1 device, and a 600 Vac rating, it streamlines panel design and reduces stocking complexity. For users, the result is safer operation, faster service, and lower lifecycle cost in hazardous-area control stations and other demanding industrial applications.
Product Information
Extended Description
EDSC3184 ST Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS pushbutton control station, With pushbuttons, Stop, Feraloy iron alloy, Single circuit universal, 1, Single-gang, 1, Through feed, 1", 600 Vac
Product Name
Eaton Crouse-Hinds series EDS pushbutton control station
Catalog Number
EDSC3184 ST
Product Length/Depth
3.5 in
Product Height
6.97 in
Product Width
5.81 in
Product Weight
7.75 lb
UPC
782274898070
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 2 Class II, Division 1 Class II, Division 2 Class III Class I, Division 1
NEMA Rating
3 7 9
Enclosure type
With pushbuttons
Voltage rating
600 Vac
Number of gangs
Single-gang
Number of pushbuttons
1
Number of devices
1
Normal position
Single circuit universal
Indicating plate markings
Stop
Style
Through feed
Trade size
1"
Material
Feraloy iron alloy
SP3D Design Package - EDS and EFS Explosionproof Control Stations
EDS/EDSX Hazardous Area Control Stations catalog page
EDS and EFS Explosionproof Pushbutton, Pilot Light, and Selector Switch Control Stations UL certification
EDS and EFS Explosionproof Pushbutton, Pilot Light, and Selector Switch Control Stations UL certification
IF 328 - EDS, EFS, EDSC and EFSC Single- and Two-gang Device Bodies
IF 328 - EDS, EFS, EDSC and EFSC Single- and Two-gang Device Bodies
IF 328 - EDS, EFS, EDSC and EFSC Single- and Two-gang Device Bodies
Eaton Specification Sheet - EDSC3184 ST
Through-feed, single-gang enclosure with one pushbutton reduces wiring complexity and panel depth, enabling faster installs and easier troubleshooting in hazardous-area control cabinets. The 600 Vac rating combined with a 1" trade size supports main process control circuits, reducing the need for multiple devices on the same feeder and simplifying spare-part inventory for oil & gas and chemical plants. Feraloy iron alloy enclosure delivers robust impact, heat, and corrosion resistance for extreme conditions, extending service life in mining and upstream/downstream operations. NEC/CEC compliance and hazardous-location ratings, including Class I, Division 2; Class II, Division 1 and 2; Class III, plus a NEMA 3, 7, 9 enclosure, reduce regulatory risk and maintenance costs while improving operator safety. The Stop-indicating plate and through-feed design help maintain clear operator cues and fast field replacement, and compatibility with EDS/EDSX families simplifies upgrades. Comprehensive installation resources, including IF328 instructions and SP3D models, speed commissioning and reduce field questions.
Get a Quick Quote for a Eaton Crouse-Hinds EDSC3184 ST
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds EDSC3184 ST?
Enquire Now
FAQs
The EDSC3184 ST is designed for single-gang mounting with a 1" trade size and supports through-feed wiring, simplifying panel layouts in hazardous areas. With 1 pushbutton and 1 device, it reduces hardware count and wiring complexity while preserving regulatory compliance for Class I and II hazardous locations.
This control station carries NEC/CEC standards, NEC hazardous ratings including Class I, Division 2 and Class I, Division 1, Class II Division 1 and 2, and Class III, plus a NEMA rating of 3, 7, and 9. It is intended for hazardous or classified locations, ensuring compliance with global safety requirements.
Installation sheets IF 328 and related guidance are provided, along with SP3D design packages and catalog pages. Engineers can access instruction sheets for single- and two-gang device bodies, ensuring proper mounting, wiring, and through-feed connectivity in hazardous-location environments.
Ideal for hazardous-area control stations in chemical, oil and gas, mining, and other process industries, it supports on/off interlocks, emergency-stop schemes, and process sequencing in spaces where 600 Vac control is common and where robust enclosure protection is essential.
The rugged Feraloy iron alloy enclosure and sealed, through-feed construction reduce field maintenance and downtime. Fewer components simplify spare parts inventories, while NEC/CEC compliance lowers regulatory risk, contributing to lower lifecycle costs and faster payback in hazardous-location installations.