Eaton Crouse-Hinds EDSC3190 S153 Pushbutton Control Station - Hazardous/Classified Locations
Part Number: EDSC3190 S153
Quick Summary
EDSC3190 S153 is a pushbutton control station designed for hazardous locations in industrial automation applications. Operators often struggle with safe, reliable control in volatile environments where downtime is costly and maintenance is risky. This model delivers explosion-proof performance, NEC/CEC compliance, and UL-certified protection rated for Class I, Division 1 and Division 2, along with rugged NEMA ratings for 3, 7, and 9 enclosures. By combining through-feed mounting with a 1 inch trade size and a lockout provision, it supports safe maintenance and straightforward installation. With two pushbuttons across a single-gang enclosure, it offers compact control for two devices while maintaining diagnostic clarity and operator visibility.
Product Information
Extended Description
EDSC3190 S153 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS pushbutton control station, With pushbuttons, Feraloy iron alloy, Two circuit universal, 2, Single-gang, 2, Lockout provision, Through feed, 1", 600 Vac
Product Name
Eaton Crouse-Hinds series EDS pushbutton control station
Catalog Number
EDSC3190 S153
Product Length/Depth
3.5 in
Product Height
6.97 in
Product Width
5.81 in
Product Weight
8.26 lb
UPC
782274523248
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class II, Division 1 Class III Class I, Division 2 Class I, Division 1 Class II, Division 2
NEMA Rating
3 7 9
Enclosure type
With pushbuttons
Voltage rating
600 Vac
Number of gangs
Single-gang
Number of pushbuttons
2
Number of devices
2
Normal position
Two circuit universal
Style
Through feed
Trade size
1"
Material
Feraloy iron alloy
Special features
Lockout provision
SP3D Design Package - EDS and EFS Explosionproof Control Stations
EDS/EDSX Hazardous Area Control Stations catalog page
EDS and EFS Explosionproof Pushbutton, Pilot Light, and Selector Switch Control Stations UL certification
EDS and EFS Explosionproof Pushbutton, Pilot Light, and Selector Switch Control Stations UL certification
IF 899 - EDSX, EDS, EFS, DSDX and DSD Control Stations
IF 899 - EDSX, EDS, EFS, DSDX and DSD Control Stations
IF 899 - EDSX, EDS, EFS, DSDX and DSD Control Stations
Eaton Specification Sheet - EDSC3190 S153
Feature: Two pushbuttons on a single-gang enclosure, supporting two devices. Business Impact: Enables compact, two-circuit universal control in tight panels, reducing panel footprint and wiring complexity. Application: Ideal for small automation loops in hazardous areas where space is at a premium and dual control points are required. Feature: 600 Vac voltage rating and through-feed wiring. Business Impact: Handles standard industrial power safely, simplifies wiring during installation, and supports reliable operation in demanding environments. Application: Chemical plants and oil/gas facilities with high-voltage control needs. Feature: Feraloy iron alloy enclosure with lockout provision. Business Impact: Delivers rugged, explosion-protected housing that enhances maintenance safety and compliance. Application: Hazardous locations requiring robust mechanical integrity and safe servicing. Feature: Through-feed, 1" trade size, normal position two-circuit universal. Business Impact: Eases field installation and future expansions while preserving operational flexibility. Application: Through-feed installations in compact control panels. Feature: Certifications and compliance (NEC/CEC, Hazardous/Classified Locations, NEMA 3 7 9). Business Impact: Ensures regulatory conformity, safer commissioning, and reduced risk of noncompliance during audits. Application: Industrial settings with strict electrical standards and hazardous-location requirements.
Get a Quick Quote for a Eaton Crouse-Hinds EDSC3190 S153
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds EDSC3190 S153?
Enquire Now
FAQs
The EDSC3190 S153 is designed for Class I, Division 1 and Division 2 hazardous locations with a single-gang enclosure and through-feed mounting. It supports two pushbuttons and two devices at 600 Vac, using a 1 inch trade size. This makes it straightforward to install in restricted panels while meeting NEC/CEC requirements and ensuring safe maintenance access.
This control station carries NEC/CEC standards compliance and area classification for Hazardous/Classified Locations. It is UL-certified for explosion-proof service, suitable for Class I, II, and III environments, and features NEMA ratings of 3, 7, and 9 to withstand challenging industrial conditions. These certifications support safer commissioning and ongoing regulatory adherence.
The unit is rated for 600 Vac operation and uses a through-feed wiring approach with a 1 inch trade size. It supports two pushbuttons across a single-gang enclosure and two devices, offering two-circuit universal functionality. This simplifies wiring in complex panels while maintaining reliable performance in hazardous locations.
Yes. The EDSC3190 S153 features a through-feed design and a lockout provision, enabling safe maintenance and compliance with lockout-tagout practices. This combination minimizes risk during servicing, supports safer startup/shutdown sequences, and improves uptime by preventing inadvertent energization in hazardous environments.
By delivering explosion-proof protection, NEC/CEC compliance, UL certification, and rugged NEMA-rated construction, the EDSC3190 S153 reduces unplanned downtime and maintenance risk in hazardous locations. Its compact, through-feed design and two-circuit capability streamline wiring and future expansion, translating to lower lifecycle costs and faster return on investment for facilities with stringent safety and reliability requirements.