Eaton EDS pushbutton control station EDSC3190 SA S153 - Hazardous Locations

Part Number: EDSC3190 SA S153 ST SP
Eaton Crouse-Hinds logo
Manufacturer
Eaton Crouse-Hinds
Part number
EDSC3190 SA S153 ST SP

Quick Summary

EDS pushbutton control station is a rugged solution for reliable start/stop control in hazardous environments. Users frequently wrestle with wiring integrity, downtime, and maintenance costs when selecting equipment for Class I/II/III locations. This unit carries NEC/CEC compliance and multiple hazardous-area ratings, including Class I/Division 1 and Class II/Division 2, with a robust NEMA 7/3/9 enclosure. Through-feed mounting, copper-free aluminum construction, and a 600 VAC rating simplify installation, reduce lifecycle costs, and support scalable control architectures in process, mining, and manufacturing settings.

Product Information

Extended Description

EDSC3190 SA S153 ST SP Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS pushbutton control station, With pushbuttons, Start, Stop, Copper-free aluminum, Two circuit universal, 2, Single-gang, 2, Through feed, 1", 600 Vac
Product Name
Eaton Crouse-Hinds series EDS pushbutton control station
Catalog Number
EDSC3190 SA S153 ST SP
Product Length/Depth
3.5 in
Product Height
6.97 in
Product Width
5.81 in
Product Weight
8.72 lb
UPC
662276464292
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class II, Division 1 Class I, Division 1 Class I, Division 2 Class II, Division 2 Class III
NEMA Rating
7 3 9
Enclosure type
With pushbuttons
Voltage rating
600 Vac
Number of gangs
Single-gang
Number of pushbuttons
2
Number of devices
2
Normal position
Two circuit universal
Indicating plate markings
Start, Stop
Style
Through feed
Trade size
1"
Material
Copper-free aluminum
Feature → Business Impact → Application. Copper-free aluminum enclosure delivers corrosion resistance and weight savings, reducing maintenance and total cost of ownership in harsh environments such as chemical plants and mining sites, while maintaining mechanical integrity in through-feed panels. Through-feed design simplifies wiring runs and panel assembly, enabling faster commissioning and easier field troubleshooting for high-capacity production lines. A 600 VAC rating supports mainstream industrial controls, improving compatibility with motor starters and control relays across plant networks. Two pushbuttons in a single-gang, 1 inch trade-size enclosure conserve panel space and minimize installation complexity, enabling scalable control architectures for start/stop sequences. NEC/CEC compliance and hazardous-location ratings (Class I/II/III) provide regulatory confidence and safer operation in oil, gas, and chemical processing facilities. Indicating plates (Start, Stop) reduce operator errors and accelerate maintenance cycles.

Get a Quick Quote for a Eaton Crouse-Hinds EDSC3190 SA S153 ST SP

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds EDSC3190 SA S153 ST SP? Enquire Now

FAQs

The unit is designed for single-gang installation with a 1 inch trade size and through-feed wiring, enabling streamlined panel integration with other field devices. Its footprint (3.5 in depth, 5.81 in width, 6.97 in height) fits standard enclosures, while Start/Stop indication ensures clear operator sequencing and reduces wiring errors during commissioning and maintenance.
Voltage rating is 600 VAC with two pushbuttons and two devices, supporting common motor-control and start/stop circuits. Normal position is two-circuit universal, allowing flexibility in wiring schemes. The through-feed style facilitates simple backplane and conduit connections, which reduces installation time and minimizes potential miswiring compared with multi-gang assemblies.
Yes. This control station is rated for Hazardous/Classified Locations with NEC/CEC compliance, covering Class I Division 1 and Class II Division 1/2 and Class III environments. The enclosure protection aligns with NEMA ratings 7, 3, and 9, making it appropriate for oil, gas, chemical, and mining applications where reliable, compliant control is critical.
The unit carries NEC/CEC compliance and Hazardous/Classified Locations area ratings, plus NEMA 7, 3, 9 protection. Canadian certification is supported via UL-listed documentation. These certifications ensure safe operation, regulatory alignment, and ease of field approval for worldwide installations in hazardous environments.
Copper-free aluminum enclosure offers corrosion resistance, reducing rework and replacement costs in harsh environments. The compact single-gang through-feed design lowers wiring errors and panel space, speeding commissioning. Durable construction and standardized Start/Stop indicators improve uptime, while compatibility with 600 VAC circuits supports scalable, long-term investment in control architectures across process plants.