Eaton EDSC3192 GB Pushbutton Control Station - Hazardous

Part Number: EDSC3192 GB
Eaton Crouse-Hinds logo
Manufacturer
Eaton Crouse-Hinds
Part number
EDSC3192 GB

Quick Summary

EDSC3192 GB pushbutton control station enables safe, reliable control in hazardous locations. Users often wrestle with downtime and compliance overhead in Class I, Division 1 environments, impacting productivity and maintenance costs. This unit supports NEC/CEC standards and robust NEMA enclosures, delivering reliable performance under demanding conditions. With two pushbuttons in a single-gang, through-feed design rated for 600 Vac and built from Feraloy iron alloy, it reduces wiring complexity while improving installer efficiency and long-term ROI. Secondary benefits include compatibility with explosion-proof control systems and streamlined integration into existing hazardous-area control schemes.

Product Information

Extended Description

EDSC3192 GB Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS pushbutton control station, With pushbuttons, Feraloy iron alloy, Two circuit universal, 2, Single-gang, 2, Suitable for Class I, Division 1, Group B, Through feed, 1", 600 Vac
Product Name
Eaton Crouse-Hinds series EDS pushbutton control station
Catalog Number
EDSC3192 GB
Product Length/Depth
3.5 in
Product Height
6.97 in
Product Width
5.81 in
Product Weight
6.94 lb
UPC
782274896496
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class III Class I, Division 1 Class I, Division 2 Class II, Division 1 Class II, Division 2
NEMA Rating
7 9 3
Enclosure type
With pushbuttons
Voltage rating
600 Vac
Number of gangs
Single-gang
Number of pushbuttons
2
Number of devices
2
Normal position
Two circuit universal
Style
Through feed
Trade size
1"
Material
Feraloy iron alloy
Special features
Suitable for Class I, Division 1, Group B
Feature: Through-feed, single-gang enclosure with two pushbuttons; Business Impact: Simplifies wiring, cuts installation time by eliminating multiple termination points; Application: Hazardous-area control stations in Class I, Division 1 environments. Feature: Two circuit universal design; Business Impact: Flexible control logic supports both maintained and momentary operations, reducing part numbers and stock. Application: Start/stop or pilot-light control in hazardous settings. Feature: Feraloy iron alloy construction; Business Impact: Enhanced mechanical strength and corrosion resistance for rugged environments; Application: Offshore, mining, and chemical processing facilities. Feature: 600 Vac rating; Business Impact: Direct compatibility with standard industrial control circuits, minimizing auxiliary equipment; Application: Industrial automation panels and safety interlocks. Feature: Class I Division 1, Group B suitability; Business Impact: Regulatory compliance and safer operation in flammable atmospheres; Application: Hazardous-location machinery control. Feature: NEMA 7/9/3 ratings; Business Impact: Superior enclosure protection against dust, water, and impact; Application: Harsh industrial environments where uptime matters. These attributes support predictable maintenance, reduced rework, and improved overall equipment effectiveness in explosion-resistant applications.

Get a Quick Quote for a Eaton Crouse-Hinds EDSC3192 GB

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds EDSC3192 GB? Enquire Now

FAQs

To install EDSC3192 GB, mount in a single-gang enclosure with a 1" trade size and through-feed wiring. Route two pushbutton circuits through a rugged Feraloy iron alloy housing rated for 600 Vac. Ensure enclosure and wiring comply with NEC/CEC Hazardous Location requirements, and verify that the installation meets Class I Division 1, Group B specifications for safe operation.
EDSC3192 GB features two pushbuttons, two devices, and two circuits in a single-gang enclosure. It has a 1" trade size, is rated for 600 Vac, and is designed for through-feed wiring. The device supports two-pole control in hazardous locations and is suitable for Class I, Division 1, Group B environments, aligning with NEC/CEC standards.
EDSC3192 GB is part of Eaton Crouse-Hinds’ explosion-proof control station family. Its through-feed, single-gang design complements EDS/EDSX ecosystems by providing a compact two-pushbutton solution that can be integrated into larger hazardous-location control schemes. For retrofits, confirm enclosure dimensions and mounting compatibility with existing panels and ensure wiring practices match through-feed installation guidelines.
The EDSC3192 GB is certified for NEC/CEC compliance and suitable for Hazardous/Classified Locations. It carries NEC hazardous ratings including Class I, Division 1, Group B, and features NEMA ratings 7, 9, and 3. These certifications support safe operation, regulatory adherence, and insurance compliance for equipment located in hazardous industrial environments.
The rugged Feraloy iron alloy construction and explosion-proof design reduce corrosion and wear, lowering replacement frequencies in harsh environments. The two-pushbutton, through-feed arrangement minimizes wiring complexity and installation time. Over time, reduced downtime and simpler conformity to safety standards contribute to a favorable total cost of ownership and measurable ROI in hazardous-area automation projects.