Eaton Crouse-Hinds EDSC3199 P37 Motor Starter - Hazardous
Part Number: EDSC3199 P37
Quick Summary
The EDSC3199 P37 motor starter control station is a compact motor control solution designed for hazardous locations. Engineers often struggle to align compliant enclosures, heaters, and wiring schemes when upgrading to explosion-protected starters. This unit delivers NEC/CEC compliance with Class I Division 1 ratings, plus Class II/III allowances and a NEMA 9/7/3 enclosure, enabling safer installations in demanding environments. With features such as single-pole operation, 1 hp rating, two 1" hubs, and a rugged Feraloy iron alloy body, it streamlines installation and reduces downtime while delivering reliable performance for mission-critical equipment.
Product Information
Extended Description
EDSC3199 P37 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EDS manual motor starter control station, Single-pole, With switch, 1 HP, With two 1" hubs, Feraloy iron alloy, Single-gang, With 12.00A Allen Bradley heater, Through feed, 1"
Product Name
Eaton Crouse-Hinds series EDS manual motor starter control station
Catalog Number
EDSC3199 P37
Product Length/Depth
3.5 in
Product Height
6.97 in
Product Width
5.06 in
Product Weight
8.02 lb
UPC
662276094338
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class II, Division 2 Class II, Division 1 Class III Class I, Division 2
NEMA Rating
9 7 3
Enclosure type
With switch
Number of gangs
Single-gang
Configuration
Single-pole
Style
Through feed
Trade size
1"
Horsepower
1 hp
Hub style
With two 1" hubs
Material
Feraloy iron alloy
Special features
With 12.00A Allen Bradley heater
EDS Series Explosionproof Motor Starter Control Stations catalog page
EDS Explosionproof Motor Starter Control Stations UL certification
EDS Explosionproof Motor Starter Control Stations UL certification
IF 372 - EDS Notice
IF 372 - EDS Notice
IF 372 - EDS Notice
Eaton Specification Sheet - EDSC3199 P37
Feature: Single-pole configuration paired with a 1 hp rating. Benefit: Simplifies control logic and reduces panel footprint, improving installation efficiency and cutting wiring errors during commissioning. Application: Small- to mid-size motor loads in hazardous areas. Feature: Through-feed design and single-gang enclosure. Benefit: Enables fast field wiring and compact operator access, minimizing panel space and enabling faster maintenance cycles. Application: Control stations for motors on conveyors and pumps in hazardous environments. Feature: Two 1" hubs for hubs and through-feed routing. Benefit: Eases cable management and allows clean, scalable wiring runs, reducing installation time and potential fault points. Application: Through-feed starters in process lines and mining equipment. Feature: Feraloy iron alloy enclosure. Benefit: Superior hardness and resistance to mechanical abuse and corrosion in demanding environments. Application: Industrial plants with rigorous service demands. Feature: 12.00A Allen Bradley heater. Benefit: Improves thermal stability and reduces nuisance tripping during start-up and load changes. Application: Motors with high-inrush characteristics in hazardous locations. Feature: Certifications and compliance (NEC/CEC, hazardous ratings). Benefit: Facilitates regulatory approval and installation across multiple jurisdictions, mitigating risk and accelerating project timelines. Application: Any installation requiring strict compliance for Class I, II, and III locations. This combination supports safer, faster commissioning and lower lifecycle costs.
Get a Quick Quote for a Eaton Crouse-Hinds EDSC3199 P37
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds EDSC3199 P37?
Enquire Now
FAQs
Yes. The EDSC3199 P37 is designed for through-feed wiring in single-gang enclosures and supports two 1" hubs, enabling straightforward integration into existing control panels. Its rugged Feraloy housing and NEC/CEC compliance help ensure seamless integration with current protection schemes and heater choices, reducing field modifications and installation time.
Key specs include a 1 hp horsepower rating, single-pole configuration, through-feed style, and a 1" trade size. It also features a 12.00A Allen Bradley heater and a weight of about 8.02 lb. Enclosure and wiring are designed for hazardous locations with NEC/CEC compliance and Class I, Division 1 ratings.
Yes. The unit is certified for hazardous/classified locations with Class I, Division 1 and Class II, Division 1/2, Class III ratings, along with a compatible NEMA rating. These features make it appropriate for mining and chemical processing where explosive atmospheres or corrosive environments may be present, while maintaining safe motor control.
The EDSC3199 P37 complies with NEC/CEC standards and NEC hazardous ratings, including Class I Division 1, Class II Division 1/2, Class III, and Class I Division 2. It is designed for hazardous locations and aligns with recognized certification programs, easing cross-border deployment and reducing regulatory risk.
The unit’s rugged Feraloy iron alloy enclosure and heater-integrated design reduce nuisance trips and wear, lowering maintenance frequency. With proven hazardous-location ratings and a compact form factor, installation and servicing are faster, downtime is minimized, and lifecycle costs are improved due to fewer field modifications and durable construction.