Eaton EGF11EPD15 Ground Fault Station - Hazardous Locations
Part Number: EGF11EPD15
Quick Summary
EGF11EPD15 is a ground fault station protecting hazardous-location electrical systems in industrial facilities, offering fast trip response and reliable disconnection to minimize arc-flash risks. Nuisance trips, corrosion risk, and challenging installations can drive maintenance costs, reduce uptime, and complicate compliance audits in petrochemical or mining environments. It aligns with NEC/CEC standards, supports Class I Division 1 and Class II Division 1, Class II and Class III ratings, and offers NEMA 9, 12, 7, 3 protection for rugged hazardous locations. Designed for 120 VAC control circuits with a 15 A rating and 30 mA trip, its copper-free aluminum construction reduces weight, improves corrosion resistance, and simplifies field wiring.
Product Information
Extended Description
EGF11EPD15 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EGF ground fault control station, 15A, Copper-free aluminum, 1 breaker, Single-pole, 30 mA, 120 Vac
Product Name
Eaton Crouse-Hinds series EGF ground fault control station
Catalog Number
EGF11EPD15
Product Length/Depth
6.88 in
Product Height
9.88 in
Product Width
7.81 in
Product Weight
13.57 lb
UPC
782274877891
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class II, Division 1 Class I, Division 1 Class II, Division 2 Class III Class I, Division 2
NEMA Rating
9 12 7 3
Number of breakers
1
Number Of Poles
Single-pole
Trip
30 mA
Amperage Rating
15A
Material
Copper-free aluminum
Voltage rating
120 Vac
EGF Series Explosionproof Ground Fault Control Stations catalog page
EGF Explosionproof Ground Fault Control Stations Canadian certification
EGF Explosionproof Ground Fault Control Stations Canadian certification
IF 1289 - EGF Series Grount Fault Control Station
Eaton Specification Sheet - EGF11EPD15
15 Ampere rating with a 30 mA trip ensures fast fault clearance and minimizes arc-flash exposure in critical control circuits. This configuration reduces nuisance trips and helps maintain process stability in hazardous locations. Copper-free aluminum reduces weight and enhances corrosion resistance, lowering handling and maintenance costs in humid or chemically aggressive environments. This material choice also improves mounting flexibility in tight control panels. NEC/CEC compliance and NEMA protection ratings provide a solid regulatory footing. The unit supports Class I Division 1, Class II Division 1, and Class III environments, along with NEMA 9/12/7/3 enclosures. Footprint and wiring considerations are favorable for standard installations: 6.88 in length, 9.88 in height, 7.81 in width, and about 13.57 lb, with a simple single-pole configuration and one breaker. Compatibility with 120 VAC control circuits and the Eaton EGF family enables seamless integration into existing safety systems, delivering faster commissioning, clearer wiring, and improved audit readiness. In demanding industries such as manufacturing, mining, petrochemical, and oil & gas, this ground fault station supports safer operations, lower lifecycle costs, and a clearer path to regulatory compliance.
Get a Quick Quote for a Eaton Crouse-Hinds EGF11EPD15
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton Crouse-Hinds EGF11EPD15?
Enquire Now
FAQs
To install the EGF11EPD15 in Class I Division 1 environments, follow NEC/CEC wiring practices for hazardous locations, mount in a compliant enclosure, and connect the 120 VAC supply to the single-pole, 15 A circuit with a 30 mA ground fault trip. Verify proper grounding and use listed mounting hardware compatible with copper-free aluminum enclosures. Ensure labeling reflects hazardous-location ratings and maintain to OSHA/IEC standards.
The EGF11EPD15 features a 15A amperage rating, 120 VAC operating voltage, one breaker, single-pole configuration, and a 30 mA trip setting. It uses copper-free aluminum for its enclosure, weighs approximately 13.57 lb, and has a footprint of 6.88 in length by 9.88 in height by 7.81 in width. UPC for product identification is 782274877891.
Yes. The unit is designed for hazardous locations and supports Class I Division 1, Class II Division 1, and related ratings, along with NEC/CEC compliance and NEMA protection (9, 12, 7, 3). Its robust copper-free aluminum construction and 30 mA trip provide reliable protection in challenging environments typical of mining or chemical processing facilities, while maintaining ease of installation.
It carries NEC/CEC standards certification and area classifications for Hazardous/Classified Locations, plus NEMA ratings 9, 12, 7, and 3. These certifications confirm suitability for Class I and II hazardous environments, support regulatory compliance, and ease procurement by aligning with common industrial safety requirements across North America.
The EGF11EPD15 offers low maintenance due to its durable copper-free aluminum construction and single-pole design, reducing wiring complexity and spares requirements. By minimizing nuisance trips and enabling faster fault isolation, it lowers downtime costs and accelerates commissioning, delivering measurable safety and productivity gains over the device’s service life.