Eaton EIDA3060 S784 Disconnect Switch - Hazardous Locations

Part Number: EIDA3060 S784
Eaton Crouse-Hinds logo
Manufacturer
Eaton Crouse-Hinds
Part number
EIDA3060 S784

Quick Summary

The Eaton EIDA3060 S784 disconnect switch is a rugged device for hazardous-location electrical isolation. In harsh industrial environments, downtime and compliance risk rise quickly when equipment isn’t certified for Class I/II locations. It carries NEC/CEC compliance and hazardous-area ratings, including Class I Zone 2, Class I Division 1, and Class II Division 1, to support safe operation. With a copper-free aluminum body, 60 A rating, non-fused design, and an auxiliary contact, it enables straightforward installation, reliable signaling, and reduced lifecycle costs for maintenance teams and EPCs alike. This combination delivers faster risk assessment, easier audits, and stronger ROI for capital projects.

Product Information

Extended Description

EIDA3060 S784 Eaton Crouse-Hinds: Eaton Crouse-Hinds series EID disconnect switch, 60A, With switch, Non-fused, 10 HP/20 HP/40 HP, Copper-free aluminum, Auxiliary contact (single block), 240-600 Vac/250 Vdc
Product Name
Eaton Crouse-Hinds series EID disconnect switch
Catalog Number
EIDA3060 S784
Product Length/Depth
10.47 in
Product Height
12.47 in
Product Width
9.65 in
Product Weight
36 lb
UPC
662276155978
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Zone 2 Class I, Division 1 Class I, Division 2 Class I, Zone 1 Class II, Division 1 Class III
NEMA Rating
3R 9 4 3 7
Enclosure type
With switch
Fusing
Non-fused
Amperage Rating
60A
Horsepower
10 hp/20 hp/40 hp
Material
Copper-free aluminum
Special features
Auxiliary contact (single block)
60A amperage rating and 10 hp/20 hp/40 hp motor capability allow direct disconnect of standard hazardous-location loads without external fusing. The business impact is improved safety, reduced motor stress, and faster lockout procedures during maintenance. In field applications such as conveyors, pumps, or fans in Class I/Zone 2 environments, this compact switch provides reliable control with minimal wiring complexity. Copper-free aluminum construction reduces weight and eliminates copper corrosion concerns in humid or corrosive environments, helping lower total installed cost through easier handling and fewer maintenance events while still meeting rugged service demands. Enclosure type With switch and non-fused design simplifies replacement and interlocking with existing control schematics. The auxiliary contact provides clean status signaling and enables interlock logic or remote indicators, reducing the risk of misoperation during startup or maintenance. Compliance and standards include NEC/CEC compliance and hazardous-area ratings such as Class I Zone 2, Zone 1, Division 1 and 2, and Class II/III, with NEMA 3R support for outdoor installations. These certifications help streamline audits and ensure safe operation across facilities. Installation and integration resources, including SP3D design packages and IF 1532 installation instructions, reduce engineering time and ensure correct mounting, wiring, and code-compliant interconnections, translating to faster project completion and fewer rework cycles. In practice, customers report lower downtime thanks to clear signaling from the auxiliary contact and a streamlined maintenance workflow.

Get a Quick Quote for a Eaton Crouse-Hinds EIDA3060 S784

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton Crouse-Hinds EIDA3060 S784? Enquire Now

FAQs

Yes. The EIDA3060 S784 is designed for Class I hazardous locations and supports Zone 2 operation with additional classifications noted in NEC/CEC standards. To ensure proper performance, install per the IF 1532 instructions and verify enclosure integrity, mounting, and wiring in accordance with local codes.
The device handles 60A with motor options of 10, 20, and 40 HP. It operates across a wide range of voltages: 240-600 VAC or 250 VDC. This makes it suitable for a variety of hazardous-location motor circuits without external fusing, simplifying design and maintenance.
An auxiliary contact (single block) is included to provide status signaling and enable interlock logic or remote indicators. Eaton also offers SP3D design packages and official datasheets to accelerate integration and ensure consistent control wiring and enclosure compatibility with existing protection schemes.
The EIDA3060 S784 carries NEC/CEC compliance and hazardous-location ratings (Class I Zone 2, Division 1, and Zone 1; Class II/III), along with a NEMA 3R rating. This reduces audit complexity, improves safety margins, and lowers maintenance downtime through reliable signaling and robust enclosure construction.
Access IF 1532 installation instructions, SP3D design packages, and catalog pages to streamline mounting, wiring, and interconnections. These resources help projects reach completion faster, minimize field rework, and ensure consistent, code-compliant installations across multiple sites.